Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.25 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.18...0.25 A |
Suitable for induction motors with P | 0.06 kW |
Instantaneous overcurrent releases | 3.3 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.246 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.18...0.25 A
N-release 3.3 A Screw terminal Standard switchingcapacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.18 - 0.25
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.25 A
operating current
at AC-3 at 400 V rated value 0.25 A
operating power at AC-3
at 230 V rated value 37 W
at 400 V rated value60 W
at 500 V rated value90 W
at 690 V rated value120 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 3.3 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.25 A
at 600 V rated value0.25 A
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-0CA15
People who bought this item also viewed
Siemens Circuit Breaker 3RV5041-4KA10
Siemens Circuit Breaker 5SL6116-7CC
Siemens Circuit Breaker 3RV1021-1JA10
Siemens Circuit Breaker 3RV1011-0HA10
Siemens Circuit Breaker 3VL6780-2SB36-0AA0
Fuji Circuit Breaker EW50AAG-2P020
Fuji Circuit Breaker EW50RAGU-3P030B
Siemens Circuit Breaker 3RV2011-1BA15
TRIAD Transformer F36-65
Eaton Contactor DILM17-01(RDC240)
Aupo Fuse BF99X
HONGFA Relay HFKC-005-HST
UniOhm Resistor 0603WAJ047JT5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Nichicon Capacitor LKG1V102MESYCK
Omron Sensor ZX-SAM14
SMC Solenoid Valve SY5220-1MZE-01
COKERY Belt HTD 720-8M
Recent related posts
-
03/15/2021
FANUC FANUC spindle drive fault diagnosis
The motor does not rotate or the speed is abnormal After starting the spindle drive system, if the main motor does not rotate or the speed is abnormal, the possible causes are as follows
-
07/31/2020
Five common problems of refrigeration system
Trouble phenomenon: The cooling effect of the whole machine is poor, the water outlet is only slightly cool, and the pressure on the high pressure side and the low pressure side are found to be low when checked with the manifold pressure gauge (under the normal speed of the compressor
-
07/23/2020
The influence of capillary tube length on refrigeration system parameters and troubleshooting
The capillary tube generally refers to a slender copper tube with an inner diameter of 0.4~2.0mm. As the throttling mechanism of the refrigeration system, the capillary tube is the simplest one. Because of its low price and flexible selection, it is widely used in small refrigeration devices.
-
09/30/2022
Three Control Methods of Servo Motor
There are three types of <strong>servo motor control</strong> modes (<strong>servo motor control techniques</strong>)
-
08/05/2022
FANUC Spindle Amplifier Alarm Codes and Solutions (2)
The following is a continuation of the previous article, and introduces FANUC spindle drive alarm codes 24-46.
-
02/06/2024
A Comprehensive Guide: How to Turn off Oven Cooling Fan
Oven cooling fans are designed to dissipate heat and maintain safe temperatures during or after cooking.
-
09/02/2020
There are 8 reasons for the high fuel consumption of air compressors, some of which can't be thought of!
Run oil In our daily work, we often encounter the problem of air compressor running oil. In addition to the quality of the oil itself, what other reasons can cause the running oil? In practice, engineers have summed up several reasons that can cause oil running. Let's share with you.
-
01/03/2023
Parameters of the Solenoid Coil
The solenoid coil is tightly wrapped up on a core to form a solenoid. The main parameter of the solenoid coil is the size of the inductance.
-
08/20/2020
How to maximize energy saving of industrial chillers
1. Industrial water chillers prevent and reduce pipeline fouling to improve the heat exchange efficiency of condensers and evaporators. If water treatment is not done well, calcium
-
06/13/2020
Principle of magnetic suspension refrigeration compressor
Principle of magnetic suspension refrigeration compressor With the development of electronic technology, control engineering, signal processing components, electromagnetic theory and new electromagnetic materials and rotor dynamics, magnetic levitation t ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džቜ먢䇨珵呈ᠾ뤂ᐱ ⬿먲僧ᐱ靖㥲ᐲ�僬㣢ᐲ ᠾ 靖랖僧Ҏ ﯼ靖 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ ﯼ戴 ﯤ艏S練