Series | SM Series |
Type | Scroll compressor |
Refrigerant | R22 |
Segment usage | Air conditioning |
Voltage | 400-460 V |
Phase | 3 Ph |
Frequency | 50-60 Hz |
Net Weight | 90 kg |
Cooling capacity 50Hz (Btu/h) | - |
Cooling capacity 60Hz (Btu/h) | 163140 |
Danfoss Compressor SM160T4CC
People who bought this item also viewed
GMCC Compressor PA270X3CS-3MUU
Bristol Compressor H25A56QDBEA
Hitachi Compressor ASL155SN-C7EU
Daikin Compressor 1YC32AXD
Danfoss Compressor 103G6660
Danfoss Compressor MTZ22JC4AVE
Danfoss Compressor 101Z0200
Danfoss Compressor MLZ048T4LC9
Bristol Compressor H23B263ABKA
Tecumseh Compressor AE4450Z-FZ1A
Copeland Compressor ZB58KQE-TFD-550
Danfoss Compressor SZ160T4RC
TRIAD Transformer F-193U
Danfoss Expansion Valve 068Z3370
Schneider Contactor LC1D150006M5C
Ebmpapst Fan 4182N/12X
LIMING Electric Motor LK-SH11-100-02+B
PARKER Filter 200-35-DX
EMERSON Sight Glass HMI-STT5
KEMET Capacitor 200V 0.0001UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Danfoss Expansion Valve 068Z3369
SUNX Sensor GX-112MLKA
IFM Sensor IV5011
COMAIR ROTRON Fan MTD24R0X-E2
SHAKO Air Cylinder JC50B60-H-M
Huba Control Transmitter 699.913214043
Recent related posts
-
10/25/2021
How to Use Rotary Encoder on Arduino Board UNO
In our last article, you may have learned how to connect a rotary encoder on Arduino development board UNO.
-
10/28/2021
How Much is a Central Air Conditioner - Prices of Different Types of Central Air Conditioners
A quote of a central air conditioner consists of the following prices: equipment (outdoor unit & indoor unit) + materials + installation cost + maintenance cost.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ①Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ①Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/17/2020
The effect of insufficient refrigerant charge on the chiller
1. If the suction pressure and discharge pressure of the compressor are lower than the normal value, then you need to check to see if it is due to insufficient refrigerant charge.
-
08/14/2020
Need heat preservation for precision air conditioner cooling pipes
Whether the cooling water pipes of precision air conditioners should be insulated depends on specific conditions. Under normal circumstances, it is not insulated,
-
04/18/2023
How a Refrigeration Compressor Works
The refrigeration compressor is the core component of the refrigeration unit, and plays a decisive role in the running performance, noise, vibration and service life of the system.
-
03/01/2023
The Structure and Basic Working Principle of Air Cylinder
Air cylinder is composed of cylinder barrel, end cap, piston, piston rod, and sealing ring.
-
09/11/2020
Discussion on the Key Technology of DC Inverter Air Conditioner Control
Inverter air conditioners have become a hot spot for the development of air-conditioning companies because of their energy-saving, comfortable, and high-energy-efficiency advantages and conform to the national policy of "energy saving and emission reduction".
-
07/11/2020
Screw compressor principle and structure
Screw compressor principle and structure content Screw compressor characteristics Screw compression principle DXS compressor structure Application of DXS compressor in YCWS unit Screw compressor characteristics
-
07/04/2020
Several common failures reported by Taikang compressor customers
No matter what product business you do, customer feedback and market research are very important. If you come up with a product, the customer's response is not good, and no matter how much effort you make, how much publicity will be useless and a waste of time.