Duracarb Tool for Metal Cutting DIMN 2 DC164
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COSEL Power Supply CBS1002424-F2
OMRON Relay MKS3P-2 DC48
SIEMENS Capacitor B41252-A6129-M
LEEMIN Filter TZX2-800-10Q3
Schneider Sensor XS230BLNBM12
MINDMAN Air Cylinder MCJT-11-50-20M
Yuken Solenoid Valve DSG-03-3C6-A110-50
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/27/2021
Why a Compressor is Used in the Refrigeration System
Why are refrigeration compressors used in small and medium-sized refrigeration systems? The compressor is the core equipment in the refrigeration system
-
06/22/2020
Reasons for poor cooling of air conditioners
The temperature in summer is high, and many of the owners' friends need air conditioning to spend the hot summer in the room. However, some owners often have such problems when using air conditioning in summer, such as poor air conditioning cooling. So, what are the reasons for poor air conditioning and cooling? How to solve the poor air conditioning and cooling? One of the reasons for poor air-conditioning and cooling: Freon is not enough (commonly known as fluoride deficiency) <img src="{{media url="magefan_blog/Reasons_for_poor_cooling_of_air_conditioners.jpg"}}" alt="" />
-
06/14/2020
External balance thermal expansion valve
The difference between the external balance type thermal expansion valve and the internal balance type in structure and installation is that the space under the diaphragm of the external balance type valve is not in communication with the outlet of the va 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ۖ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
08/08/2020
Types and differences of various refrigerants
Types and differences of various refrigerants 1. R22 is widely used in my country. Some experts believe that if R123 can finally be lifted, then the day when R22 is lifted will not be far away.
-
07/24/2022
4 Common Causes of Water Pump
Most people know that a water pump is important to vehicle operation, but not everyone knows the four most common causes of water pump failure.
-
08/13/2020
How many of these problems have you encountered with cold storage equipment
The installation of refrigeration system equipment and refrigerant pipelines, even the overall design of the cold storage and the daily use of the cold storage, must be done in strict accordance with the specifications.
-
09/06/2020
Air compressor alarm mechanism, how much do you know
As a mechanical equipment for manufacturing compressed air, air compressors are inevitable due to long-term operation. If the air compressor fails, it will affect the production of the user enterprise and cause losses.
-
07/14/2020
Teach you 10 self-cooling drinks, do it whenever you want
1. First cut the oranges and lemons into small corners, this is not a big deal, just put it in a glass. 2. The orange and lemon corners are accumulated in the glass. There will be juice on one side and fragrance oil in the peel on the other side, so if you squeeze it under the mouth of the cup, the aroma will be much stronger.
-
08/12/2020
Precautions for the use of ultra-low temperature storage boxes
The ultra-low temperature storage box is shipped after more than 12 hours of debugging before leaving the factory. Today, the editor of the ultra-low temperature storage box okmarts.com will share with you, there are some problems that should be paid atte¨ﰨ2 䀀 湠疨 V ǜ