current(A):220V-8.91A,380V-5.16A
speed(RPM):1420
Eff(%):81
power factor:0.81
T start/Tn(times):2.2
T max/Tn(times):2.3
T min/Tn(times):1.5
Is/Tn(times):7
Noise dB(A):64
SITI Electric Motor FC100LA4 2.2KW
People who bought this item also viewed
Liming Electric Motor 4IK25A-C-SS-2
ABB Electric Motor M2QA80M4B 0.75KW
BROAD-OCEAN Electric Motor Y6S443C022
Mitsubishi Servo Motor HF-SE102B
SEND Speed Reducer SZG-30R-200-5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CHINT Switch JS14P 99s AC220V
Recent related posts
-
08/17/2020
Why is the meter still running after the air conditioner is shut down
In the process of using home appliances, friends will always encounter some weird problems more or less. For example, the air conditioner makes strange noises, the soymilk machine suddenly stops turning, and so on
-
11/05/2021
Understand VFD Better by Wiring the Main Circuit and Control Circuit
1.1 Open the cover by squeezing the grooves on both sides of the VFD(variable frequency drive), remove the wire baffle, connect the terminals R, S, T to the power, connect the terminals U, V, W to the motor, and connect the earth wire at the ground symbol.
-
05/31/2022
How to Choose The Right PC Power Supply?
Power supplies are often overlooked, but they are a vital component in any desktop PC. We’re going to cover the basics, so you’ll know what to look for when selecting a new PSU.
-
08/12/2020
Causes and troubleshooting of refrigeration solenoid valve failure
The refrigeration solenoid valve is an industrial equipment controlled by electromagnetic, used in the industrial control system to adjust the direction, flow, speed and other parameters of the medium.
-
08/21/2020
What is a shell and tube condenser How can the chiller save more power
Recently, some friends left a message to okmarts.com asking what is a shell and tube condenser? How to operate the chiller to save electricity? Today, the editor of okmarts.com will take you to learn more, and hope the following content can help you.
-
06/28/2020
Hitachi compressor model sample parameters
Hitachi compressor model sample parameters W Cooling Capacity Btu/h COP (A) Compressor (B)
-
06/20/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
09/10/2020
Air compressor selection and energy saving methods
I. Overview Among many commonly used energy sources, compressed air can be said to be one of the popular energy sources second only to electricity. Although the use of compressed air has not yet penetrated into ordinary households like electricity,
-
08/24/2020
Air conditioning cleaning service ushered in new air outlet
The weather is getting hot and the air conditioner cannot be turned on? Especially how to use central air conditioners in office buildings, shopping malls, enterprises and public places? What preparations should be made before turning on the air conditioners?
-
09/04/2020
The difference between air compressor inverter and soft starter
Soft starter concept Soft start (also known as soft starter, motor soft starter, soft starter) Soft start is a novel motor control device that integrates motor soft start, soft stop, light load energy saving and multiple protection functions.