Piston diameter: 25 mm
Type code: ADNGF
Based on norm: ISO 21287
Cushioning: Elastic cushioning rings/pads at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor
Protection against torsion/guide: Guide rod with yoke
Operating pressure: 1 bar - 10 bar
Mode of operation: Double-acting
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress
Ambient temperature: -20 to 80 Celsius Degree
Impact energy in the end positions: 0.3 J
Theoretical force at 6 bar, retracting: 247 N
Theoretical force at 6 bar, advancing: 295 N
Moving mass at 0 mm stroke: 85 g
Additional weight per 10 mm stroke: 28 g
Basic weight with 0 mm stroke: 191 g
Additional moving mass per 10 mm stroke: 11 g
Pneumatic connection: M5
Note on materials: RoHS-compliant
Cover material: Anodized: Aluminum
Seals material: TPE-U(PUR)
Piston rod material: High-alloy steel
Material of cylinder barrel: Smooth anodized: Wrought aluminum alloy
Festo Air Cylinder ADNGF-25-25-P-A
People who bought this item also viewed
MINDMAN Air Cylinder MCRPLF-90-25-500
AirTAC Air Cylinder JSI100X400S
CAMOZZI Air Cylinder 61M2P063A0305
Festo Air Cylinder DGSL-8-80-Y3A
Festo Air Cylinder DRRD-16-180-FH-Y9A
Festo Air Cylinder ADVU-63-70-P-A
Festo Air Cylinder DNC-80-1000-PPV-A-KP
Festo Air Cylinder DMM-20-50-P-A
AirTAC Air Cylinder ACQ32X10S
Festo Air Cylinder ADVULQ-16-10-A-P-A-S2
Festo Air Cylinder ADNGF-32-20-PPS-A
KOGANEI Solenoid Valve A110-4E2-L
Honeywell Actuator ML6421B1040
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Sensor SME-8-K-LED-24
Relpol Relay RM40-3021-8H5-1012
PIZZATO Switch FR 13A2-M2
ABB Circuit Breaker 10099499
LIMING Electric Motor CM09RG150TJBT
Recent related posts
-
07/02/2020
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144 Pictured here: the United States US Youle MANEUROP compressor MTZ144 Product features of MTZ144: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably.
-
08/15/2020
The correct operation method of air-cooled refrigerator
For companies that use air-cooled refrigerators, the stable use of equipment is the most important thing, and if you don’t pay much attention during use, it will cause problems with the stability of the equipment due to some external factors.
-
05/29/2023
How to Tell If AC Compressor is Bad
Air conditioning systems have several components that assist in the cooling of the air. These components are the compressor, condenser and evaporator.
-
08/02/2020
Basic principles of data center cooling and energy saving solutions
Each data center has its own characteristics, so there is no technical solution that can be applied to any data center. This document mainly discusses some basic principles and technical issues in data center cooling and energy saving.
-
08/09/2020
The meaning of pipe diameter De, DN, d, ф
The meaning of pipe diameter De, DN, d, ф<br></br> The respective ranges of De, DN, d, ф<br></br> De-- PPR, PE pipe, polypropylene pipe outer diameter<br></br>
-
08/11/2020
The load calculation formula of computer room air conditioner
The load calculation formula of computer room air conditioner<br></br> How to obtain heat and cooling load in the computer room and how to calculate the cooling capacity required in the constant temperature and humidity room.
-
06/14/2020
Data Center Refrigeration System 41 Questions and Answers
How to repair the air conditioner compressor failure In summer, air conditioning is used more often, and the cooling effect of the air conditioner depends on the compressor, so once the cooling effect disappears, it means that the compressor has failed. 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
06/14/2020
What are the types of refrigerators Introduction to the four types of refrigerators 【Detailed explanation】
There are many inventions and creations in our lives that can provide us with convenience and comfort. It is because of these inventions and creations that we can have a better life. So it is worth mentioning the refrigerator. Many people don’t know much 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/23/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.