There is no price at present, you can Request a Quote
Piston diameter: 32 mm
Type code: DGC
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic shock absorber, soft characteristic curve: Pneumatic shock absorber, hard characteristic curve: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Guide: Recirculating ball bearing guide: Basic guide: Sliding guide
Position sensing: For proximity sensor
Variants: Axis clamping unit: Protected recirculating ball bearing guide: Additional slide, standard, left: Additional slide, standard on right
Operating pressure: 2 bar - 8 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb X
ATEX category for dust: II 3D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db X
Explosive ambient temperature: -10Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 2 (ATEX): Zone 1 (ATEX): Zone 22 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:-:-]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 1 - Low corrosion stress: 0 - No corrosion stress: 2 - Moderate corrosion stress
For use in the food industry: See supplementary material information
Ambient temperature: -10 to 60 Celsius Degree
Cushioning length: 17.5 mm
Theoretical force at 6 bar, retracting: 483 N
Theoretical force at 6 bar, advancing: 483 N
Alternative connections: See product drawing
Type of mounting: With accessories
Pneumatic port on clamping unit: M5
Note on materials: RoHS-compliant: Free of copper and PTFE
Cover material: Wrought aluminum alloy
Seals material: NBR: TPE-U(PU)
Festo Air Cylinder DGC-32-670-GF-YSR-A
There is no price at present, you can Request a Quote
People who bought this item also viewed
Festo Air Cylinder DGC-25-625-KF-PPV-A
AirTAC Air Cylinder JSI100X400S
Festo Air Cylinder DNC-40-1000-PPV-A
Festo Air Cylinder DFM-25-100-P-A-GF
Festo Air Cylinder SLT-10-30-P-A
Festo Air Cylinder ADNGF-40-25-P-A
Festo Air Cylinder DNU-40-400-PPV-A
Festo Air Cylinder ADVULQ-32-5-A-P-A
Festo Air Cylinder DGP-18-160-PPV-A-B
MINDMAN Air Cylinder MCJT-12-12-30M
Festo Air Cylinder DNC-32-400-PPV-A-KP
HENGSTLER Encoder AC58/0012EK.42SCA
SMC Solenoid Valve SY3120-3G-C6
SIEMENS Actuator GBB331.1E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TTK VFD Frequency Converter TTK3000-4T0075G
Furnan Vane Pump VPKC-F12A2-01
ADDA Fan AB3512HB-GA0
Mitsubishi Servo Motor HF-KN43B
KOINO Switch KSL16SK3
Recent related posts
-
01/10/2021
How Air Conditioners Work
Air conditioners use refrigeration to chill indoor air, taking advantage of a remarkable physical law: When a liquid converts to a gas (in a process called phase conversion), it absorbs heat. Air conditioners exploit this feature of phase conversion by fo 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ
-
01/14/2021
Brief Analysis of Hitachi Central Air Conditioner and Daikin
In the current domestic central air-conditioning market, the central air-conditioning is still doing well with Japanese brands. But among the Japanese brands, we have to say that Hitachi is the brand of Hitachi. At present, most air conditioners use scrol 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧і 識 �僬㣢
-
11/02/2022
Detailed Classifications and Features of Electric Motors
Electric motors play an irreplaceable role in production, transmission and distribution. Each of them has their own structures, working principles, types of source power and applications.
-
08/15/2020
Precautions for operation of cold storage evaporator
Cold storage evaporators can be divided into two categories: air coolers and cooling pipes. Air coolers are generally used in cooling rooms, freezing rooms and cooling reduction rooms for cooling objects.
-
12/03/2021
Use of Differential Pressure Transmitter and Common Troubleshooting
Differential pressure transmitter is a kind of pressure measuring instrument widely used in all kinds of chemical industry.
-
11/17/2021
Why Commercial Ice Maker not Work and Solutions
In modern city life, it's easy to see ice makers in restaurants, supermarkets, bars, cafes and other places, and there are car ice makers too.
-
09/15/2021
6 Reasons for Refrigeration Compressor Not to Start
When speaking of air conditioners, everyone is familiar with them. Especially in the hot summer, we would not know how to live without it.
-
08/20/2020
Analysis and troubleshooting of common faults in cold and hot water air conditioning systems
Common faults of cold and hot water air conditioning systems mainly come from three major parts: the refrigeration system, the water pipe system and the surrounding environment.
-
04/11/2023
How to Replace Refrigerator Compressor
A compressor is a machine that compresses gas and increases the pressure of the gas at the same time. It is widely used, and common application fields include: HVAC, refrigeration cycle
-
09/02/2020
Brief analysis of the reasons for the reduction of the displacement of the screw air compressor
"Air compressors are general-purpose mechanical equipment. They are now widely used in various fields. Due to the motor power and the length of the main engine shaft, the air compressor has a large and small displacement.