Stroke: 3 mm - 2000 mm
Piston diameter: 125 mm
Type code: DNC
Based on norm: ISO 15552
Cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Piston: Piston rod: Profile barrel
Position sensing: For proximity sensor: None
Variants: Dust protection: Piston rod with external hexagon: Special thread on piston rod: Monostable pneumatic valve, fitted on left, piston rod extended when not actuated: Internal thread on piston rod: Extended external thread piston rod: Bistable pneumatic valve, fitted on right, piston rod retracted when not actuated: Piston rod at one end: Monostable pneumatic valve, mounted on right, piston rod retracted when not actuated: Low friction: Through piston rod: Constant, slow movement: Clamping unit on the piston rod: Monostable pneumatic valve, mounted on left, piston rod retracted when not actuated: Extended piston rod: Increased service life: High corrosion protection: Continuous, hollow piston rod: Monostable pneumatic valve, fitted on right, piston rod extended when not actuated: Heat-resistant seals max. 120Celsius Degree: Bistable pneumatic valve, fitted on left, piston rod retracted when not actuated
Operating pressure: 0.6 bar - 10 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 21 (ATEX): Zone 2 (ATEX): Zone 22 (ATEX): Zone 1 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 2 - Moderate corrosion stress: 3 - High corrosion stress
Ambient temperature: -40 to 120 Celsius Degree
Impact energy in the end positions: 5 J
Theoretical force at 6 bar, retracting: 6881 N
Theoretical force at 6 bar, advancing: 6881 N - 7363 N
Type of mounting: With accessories: With internal thread
Pneumatic connection: G1/2
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DNC-125-450-PPV-A-KP
People who bought this item also viewed
CKD Air Cylinder STSB-4010
Festo Air Cylinder DGC-18-450-KF-PPV-A
Festo Air Cylinder DGP-32-600-PPV-A-B
STNC Air Cylinder TGC80x50-S
Festo Air Cylinder DGP-40-650-PPV-A-B
Festo Air Cylinder ADN-20-5-I-P-A
Festo Air Cylinder AEVC-20-5-I-P-A
Festo Air Cylinder ADNGF-63-15-P-A
Festo Air Cylinder AEVC-10-10-A-P-A
CHELIC Air Cylinder MSL10*10
CKD Air Cylinder MDC2-YL-10-6
Festo Air Cylinder ADVU-12-20-A-P-A
UNIVER Solenoid Valve GH-624424
Johnson Controls Actuator M9106-AGA-2N01
Bellofram Proportional Valve 969-716-000
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Sensata-Crydom Relay CWU2425-10
KCL Vane Pump VQ215-26-6-F-RALA-02
COSEL Power Supply LFA150F-5-SGJ1Y
Recent related posts
-
03/01/2021
Matters needing attention
1.Oil and water protection of servo motor 1) The servo motor can be used in the place that will be attacked by water or oil drops, but it is not completely waterproof or oil-proof. Therefore, the servo motor should not be placed or used in the environment of water or oil invasion. 2) If the servo motor is connected to a reduction gear, the oil seal should be filled when using the servo motor to prevent the oil of the reduction gear from entering the servo motor 3) The cable of servo motor should not be immersed in oil or water.
-
06/14/2020
Does air conditioning and refrigeration rely on compressors or refrigerants, or both?
Does air conditioning and refrigeration rely on compressors or refrigerants, or both? This question seems to be asking whether to boil water in a kettle, whether it needs boiling water or a kettle. The compressor is a kettle, and the refrigerant is water 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
08/29/2020
Discussion on ways to reduce the design cost of air compressor
Reduce the friction between the end face of the crankshaft and the end face of the crankcase On the direct-coupled air compressor, the front end of the crankshaft adopts gear transmission, and the gears are divided into straight and helical teeth.
-
07/05/2020
Stationary Oil Free Air Compressor Market Analysis, Trends, Top Manufacturers, Share, Growth, Statistics, Opportunities & Forecast To 2026
Building & Construction Hold Over 20 % Share in Portable Air Compressor Market 2019 to 2027 June 25, 2020 No Comments Compressor Control SystemIndustrial Air CompressorPortable Air CompressorPortable Inverter GeneratorReciprocating CompressorRotary Screw Compressor
-
09/06/2020
What happens if the water-cooled air compressor is short of water
The cooling methods of screw air compressors are mainly divided into two types: air-cooled and water-cooled. Air-cooled air compressors are a relatively common cooling method and are used in small and medium-sized air compressors.
-
07/03/2020
Air Compressor Market Outlook: World Approaching Demand & Growth Prospect During 2020-2026, Despite COVID-19 Chaos
DataIntelo report titled Global Portable Oil Free Air Compressor Market provides detailed information and overview about the key influential factors required to make well informed business decision. This is a latest report, covering the current COVID-19 impact on the market. The pandemic of Coronavirus (COVID-19) has affected every aspect of life globally.
-
06/14/2020
Advantages of cascade cryogenic refrigeration system industrial chillers
Advantages of cascade cryogenic refrigeration system industrial chillers The cascade refrigeration system is a low-temperature refrigeration system that uses more than two refrigerants and combines them with a heat exchanger (condensation evaporator) in ﰸ2 䀀 ᅵ皥
-
08/23/2020
Teach you ten major inspection standards to see the pros and cons of air conditioners
The hot summer is approaching the peak season for air-conditioning sales and the peak period for consumers to purchase air-conditioners. Many small partners are often at a loss when faced with the variety of products on the market.
-
06/24/2020
The reason why the air conditioner is not cooling
Occasionally encounter the problem that the air conditioner does not cool in life. Don't worry at this time. The reason for the air conditioner not cooling is not very complicated. After understanding the reason for the air conditioner not cooling, you can solve the problem by taking the right medicine.
-
08/20/2020
Why does refrigerating oil deteriorate How to judge whether the refrigerant oil has deteriorated
How to choose refrigerating oil 1.Why does refrigerating oil deteriorate? First of all, we must be clear why the refrigeration oil deteriorates.