Piston diameter: 32 mm
Type code: DSBC
Cushioning: Self-adjusting pneumatic end-position cushioning: Elastic cushioning rings/pads at both ends: Pneumatic cushioning, adjustable at both ends
Mounting position: Any
Design: Profile barrel: Piston rod: Piston
Position sensing: For proximity sensor
Variants: With anti-twist protection: End-position locking at both ends: Constant, slow movement: Bellows on bearing cap: Through piston rod: Temperature range 0 to + 150 Celsius Degree: For unlubricated operation: Low friction: End-position locking with piston rod retracted: Extended external thread piston rod: Sensor slots on 3 profile sides: End-position locking with piston rod extended: Extended piston rod: Hard scraper: Low friction for balancer applications: Internal thread on piston rod: Clamping unit attached: Temperature range -40 to 80 Celsius Degree: Metal scraper: Piston rod at one end: Heat-resistant seals max. 120Celsius Degree: Increased chemical resistance
Operating pressure: 0.1 bar - 12 bar
Mode of operation: Double-acting
ATEX category gas: II 2G
Type of ignition protection for gas: Ex h IIC T4 Gb
ATEX category for dust: II 2D
Type of (ignition) protection for dust: Ex h IIIC T120Celsius Degree Db
Explosive ambient temperature: -20Celsius Degree <= Ta <= +60Celsius Degree
Explosion prevention and protection: Zone 21 (ATEX): Zone 2 (ATEX): Zone 22 (ATEX): Zone 1 (ATEX)
Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media: Operation with oil lubrication possible (required for further use)
CE marking (see declaration of conformity): as per EU explosion protection directive (ATEX)
Corrosion resistance class (CRC): 3 - High corrosion stress: 2 - Moderate corrosion stress
Ambient temperature: -40 to 150 Celsius Degree
Impact energy in the end positions: 0.4 J
Theoretical force at 6 bar, retracting: 415 N
Theoretical force at 6 bar, advancing: 415 N - 483 N
Moving mass at 0 mm stroke: 110 g
Additional weight per 10 mm stroke: 27 g
Basic weight with 0 mm stroke: 465 g
Additional moving mass per 10 mm stroke: 9 g
Type of mounting: With internal thread: With accessories: Optionally:
Pneumatic connection: G1/8
Note on materials: RoHS-compliant
Cover material: Coated: Die-cast aluminum
Material of cylinder barrel: Wrought aluminum alloy: Smooth anodized
Festo Air Cylinder DSBC-32-600-C-PPVA-N3
People who bought this item also viewed
NEW-ERA Air Cylinder PXY-SD12-1-LF
CKD Air Cylinder SCPG2-M-00-10-30
Festo Air Cylinder DNC-80-220-PPV-A
Festo Air Cylinder DSNU-16-50-PPS-A
Festo Air Cylinder SLT-25-30-P-A
Festo Air Cylinder DNC-50-125-PPV-A-S6
Festo Air Cylinder DPZ-20-25-P-A-KF
Festo Air Cylinder DNC-32-90-PPV-A
Festo Air Cylinder DFM-32-125-P-A-KF
HENGSTLER Encoder RI58-O/360ES.41KA
Belimo Actuator NRFU24-SR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NCC Capacitor 16V 2400UF
HENGSTLER Encoder AC58/1212EK.72SBD
BANDO Belt T2.5-245-14
ARK Air Cylinder KDVU50-45-A-P-A
IFM Sensor PN7036
Recent related posts
-
08/20/2020
Operation method for filling freon in refrigeration system of high and low temperature box
The operation method of filling Freon in the refrigeration system of the high and low temperature box is as follows: 1, prepare a scale, weigh the freon cylinder, and record the net weight of the total weight Leon.
-
08/17/2020
The difference between a single-head chiller and a double-head chiller
1. Single-stage refrigeration system 1. The single-stage refrigeration cycle refers to the four processes of compression, condensation, throttling,
-
07/04/2022
Magnet Pumps Selection Guide
Magnet pumps are seal-less centrifugal pumps that use a coaxial magnetic coupling to transmit torque to an impeller.
-
01/09/2024
Cooling Tower Troubleshooting and Solutions
Cooling towers are commonly used equipment in industry, air conditioning and other fields, and are used to remove the large amounts of heat generated during the production process.
-
07/16/2020
Analysis of the reason why cold storage should not be built underground
Many people think that building cold storage underground will have better thermal insulation effect than cold storage on the ground, because in the past, when the technology was backward, it was very common to choose cellars as crop storage. But from a commercial point of view, it is not scientific to blindly build the cold storage underground. The cold storage construction team stands from the perspective of consideration for customers
-
06/21/2020
The role of condensing pressure regulating valve
Condensing pressure regulating valve When the refrigeration device is running, if the condensing pressure is high, the compressor discharge temperature will rise; the compression ratio will increase; the cooling capacity will decrease; The higher the condensing pressure, the greater the above adverse effects. The high condensation pressure is mainly seen in summer. <img src="{{media url="The_role_of_condensing_pressure_regulating_valve.jpg"}}" alt="" />
-
04/23/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV430~SV449)
FANUC Servo Amplifier Alarm Codes and Troubleshooting Methods
-
09/09/2020
Pressure swing adsorption principle of adsorption dryer
Pressure swing adsorption (PSA for short) is a new gas separation technology. Taking adsorbent molecular sieve as an example, its principle is to separate the gas mixture by using the difference in the "adsorption" performance of molecular sieve on different gas molecules.
-
06/14/2020
Top 10 common faults in maintenance and debugging of refrigeration systems
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦
-
11/30/2021
Differences Between Sensor and Transmitter
Sensors and transmitters play an important role in the field of automatic control. Transmitters are developed based on sensors, which have close relationship and differences.