11/06/2023
Should the Radiator Fan Turn On When the AC Is On?
When it comes to the operation of your vehicle's cooling system, the radiator fan plays a crucial role. It helps dissipate heat from the engine coolant, ensuring that the engine stays within its optimal temperature range.
-
06/17/2020
The role of refrigerator compressors
The role of refrigerator compressors The role of refrigerator compressor The compressor is the power of the refrigerator, which is equivalent to the heart of the refrigerator, compresses the refrigerant, increases the pressure and temperature of the r 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧
-
08/19/2020
Application of large temperature difference cooling water system in industrial cooling system
In the industrial cooling system, in order to meet the process requirements, small flow materials need to be cooled with a large temperature difference (for example, a certain juice beverage needs to cool the material from 30°C to 5°C
-
09/08/2020
What is the difference between an air pump and an air compressor
Many people think that an air compressor is actually an air pump. Generally speaking, the basic principle is still the same, but there are differences in the actual structure. According to relevant data, the intake and exhaust of the air compressor have valves.
-
07/29/2020
R32 refrigerant training
Note: For products using R290 (such as dehumidifiers), if system failures are involved, automatic welding torch repairs are strictly prohibited. Please return the products to the factory according to the process.
-
07/16/2020
Vacuum leak test method for small cold storage equipment
Refrigeration systems with evaporating pressure gauges close to or below atmospheric pressure must be tested for vacuum leak tests, leaving the refrigeration equipment under proper vacuum for a certain period of time, reflecting and observing whether air has penetrated into the system from the reading of the vacuum pressure gauge for inspection The sealing performance of the cold storage equipment system.
-
03/03/2021
Voltage of servo motor: relationship between voltage and speed of servo motor
1)At high speed, the speed is proportional to the voltage 2) At low speed, the voltage is lower than the decrease of speed;
-
07/23/2020
Trouble and overhaul of piston refrigeration compressor
1. The refrigeration compressor cannot start normally Maintenance ideas 1. First, check whether it is caused by low power supply voltage or poor connection of the motor circuit. If it is indeed that the grid voltage is too low, restart after the grid voltage returns to normal: If the line is in poor contact, the connection between the line and the motor should be detected and repaired.
-
06/22/2020
What is the air conditioner that only cools
An air conditioner with only a cooling function is called a single cooling type air conditioner. 1. The single-cooled air conditioner is used in areas in the north or the south that are not cold in winter; 2. The single-cooled air conditioner model generally starts with KF; 3. Before you use the single-cooled air conditioner again, you need to clean and maintain first; 4 1. When using a single-cooling air conditioner in summer, the temperature cannot be set too low. Generally, the air conditioner temperature should be set to 26-27 degrees. <img src="{{media url="magefan_blog/What_is_the_air_conditioner_that_only_cools.jpg"}}" alt="" />
-
07/07/2020
Why defrost cold storage What are the ways to defrost
Why defrost cold storage What are the ways to defrost I. Overview: The frost on the surface of the evaporator in the cold storage hinders the conduction and distribution of the cooling capacity of the refrigeration evaporator (pipe), which ultimately affects the cooling effect.