There is no price at present, you can Request a Quote
We can also provide the following models
MC-22 DC48 50Hz 2a2b S
MC-22 DC48 50Hz 2a2b L
MC-22 DC110 60Hz S
For more information,please contact us freely
LG LS Contactor MC-9a 1316100200
There is no price at present, you can Request a Quote
People who bought this item also viewed
Nader Contactor NDC1-6540
LG LS Contactor GMC-20P2
RIKEN Contactor RAB-80N
Togami Contactor PAK-100H
HITACHI Contactor HS35
AEG Contactor LS4
GE Transformer VB2-12
ABB Circuit Breaker E3H800 R630 PR121/P-LSI
Littelfuse Fuse BLF5
Panasonic Relay JH2a-DC12V
UniOhm Resistor 3W47R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Contrinex Sensor DW-DS-606-M30-120
INFINEON IGBT Module FS660R08A6P2FLB
UniOhm Resistor 25121WF220JT4E
TYCO Relay OMI-SH-112D,394
Sanyo Denki Fan 109P0524M7D01
AirTAC Air Cylinder SC160×150
Recent related posts
-
05/02/2023
Types of Compressors for Air Conditioning and Refrigeration Applications
The compressor is the core energy-consuming component of the refrigeration system, and the capacity and characteristics of the compressor determine the performance of the refrigeration system.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
How to judge the quality of single-phase and three-phase refrigeration compressors
A compressor is a driven fluid machine that raises low-pressure gas to high-pressure gas, and is the heart of a refrigeration system. Then, after-sales maintenance sometimes doubts that the compressor is malfunctioning, how to check and judge at this time 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥
-
06/22/2020
What is the air conditioner that only cools
An air conditioner with only a cooling function is called a single cooling type air conditioner. 1. The single-cooled air conditioner is used in areas in the north or the south that are not cold in winter; 2. The single-cooled air conditioner model generally starts with KF; 3. Before you use the single-cooled air conditioner again, you need to clean and maintain first; 4 1. When using a single-cooling air conditioner in summer, the temperature cannot be set too low. Generally, the air conditioner temperature should be set to 26-27 degrees. <img src="{{media url="magefan_blog/What_is_the_air_conditioner_that_only_cools.jpg"}}" alt="" />
-
06/14/2020
Maglev Refrigeration Compressor Let central air conditioner enter the era of high energy efficiency and low operation
Maglev Refrigeration Compressor Let central air conditioner enter the era of high energy efficiency and low operation
-
03/16/2021
FANUC spindle drive repair fault treatment
FANUC spindle drive maintenance problems mainly appear as stalls, abnormal speeds, motor oscillations, jitter during processing, and main circuit overcurrent alarms. Compared with AC FANUC spindle drive maintenance problems, the primary manifestations are motor overvoltage, fuse blown, etc.
-
11/27/2021
Basics of ASHCROFT Pressure Transmitter - Performance Index, Wiring, Thread Type, Unavoidable Inaccuracies and Mounting
ASHCROFT pressure transmitter is one of the most commonly used transmitters in industrial applications.
-
06/14/2020
Analysis of common failures and causes of refrigeration compressors
Analysis of common failures and causes of refrigeration compressors The refrigeration compressor is the heart of the entire refrigeration system and the most important in the refrigeration system. Its main role is to compress the low-temperature and low- 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
07/13/2020
compressor trading platform
All basic knowledge of screw air compressor The full name of the air compressor is an air compressor; a machine designed according to the working principle of the rotation of the twin screw (also called Yin and Yang rotor) to change the volume of the gas, it can suck in natural air and then complete the work through several internal processes. To discharge compressed air that meets pressure requirements, this machine is called a screw air compressor.
-
08/17/2020
What are the effects of water quality on water-cooled chillers
If the cooling performance of water-cooled chillers is to be kept in a stable state, very strict requirements on the water source are required. In the daily use of chillers, if the company does not pay enough attention to the quality of the water source