LS Mecapion Encoder S48-8-2500ZT
Type: Encoder
Brand: LS Mecapion
Type: Encoder
Brand: LS Mecapion
Type: Encoder
Brand: LS Mecapion
STEGMANN Encoder HG660 ANK 1024 PULS/REV
LS Mecapion Encoder H40-8-2000ZV
LS Mecapion Encoder S48-8-1024ZO
LS Mecapion Encoder H40-8-0100VL
LS Mecapion Encoder S48-8-1024BT
Lika Encoder IT65-H-5000ZCP4CR
Tamagawa Seiki Encoder TS5014N152
HENGSTLER Encoder AC58/0013EK.72SGD
Renishaw Encoder RH100X15D05A
Panasonic Servo Motor MSMA082P1D
Yaskawa Servo Drive SGD7S-180A00A
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Schneider Transformer ABT7PDU032G
PQLYT Relay PQSSR-10DD 40A
ARK Air Cylinder KCDQ2A50-30D
07/09/2020
Pharmaceutical Blister Packaging Market DataIntelo, 07-07-2020: The research report on the Pharmaceutical Blister Packaging Market is a deep analysis of the market. This is a latest report, covering the current COVID-19 impact on the market.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
02/06/2024
The convection oven, with its innovative fan system, has revolutionized the way we cook, offering even heat distribution and faster cooking times.
09/15/2020
The silent oil-free air compressor used in the laboratory is specially matched with the precision instruments of the laboratory, which can provide pure air source and stable pressure. main feature
07/09/2020
Study accurate information about the Medical Air Compressor Market: Statistics, Facts and Figures, Growth Overview, Size, Major Players, Swot Analysis Industry Outlook and Regional Analysis, and Forecast To 2029. Extensive Study on Impact of the novel coronavirus (COVID-19) pandemic on the Medical Air Compressor market originally based on Current Research of Potential Growth Challenges and Future Progress till 2029.
04/20/2022
Float level meter is an instrument of measuring liquid level based on buoyancy principle. Usually, the combination of floating ball and scale enables the observer to intuitively read the height of liquid level.
07/19/2022
An oil-free lubricating pneumatic diaphragm pump belongs to the field of pneumatic machinery.
02/24/2022
As is known, the reciprocating compressor’s piston rod connects the crosshead to the piston.
03/13/2021
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
12/26/2022
The programmable logic controller (PLC) is a digital operation electronic system specially designed for application in industrial environment.