MAC Solenoid Valve PME-611JB
People who bought this item also viewed
CKD Solenoid Valve 4SB019-C3
MAC Solenoid Valve 45A-AA1-DDDJ-1KJ
MAC Solenoid Valve 45A-AA1-DDBJ-1KJ
MAC Solenoid Valve 34B-NOO-GDNC-1KT
MAC Solenoid Valve 45A-AA1-DDDA-1BA
Yuken Solenoid Valve HCG-06-A1-22
Honeywell Solenoid Valve VE4020B1145T
KOGANEI Solenoid Valve 183-4E2-13-83-PLL
Adli Transmitter 4038.179.001
SUNX Sensor GX-5SU
Saginomiya Expansion Valve WPX-3415BHC
KOMPASS Check Valve MSB-04-X
WATO Overflow Valve WGAM-10-10-100
KOMPASS Piston Pump V15-15A2R10X
MAHLE Filter OX815D
Danfoss Sight Glass SGN12
AVX Capacitor M39014-01-1299
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KOGANEI Air Cylinder JDAS16X20-B-7
Sanyo Denki Fan 109R0612M4021
CHANTO Air Cylinder JUR25X20
Recent related posts
-
09/06/2020
Application of Frequency Conversion in Oilfield Development and Energy Saving
The application of frequency conversion energy saving in the crude oil extraction industry is mainly manifested in various pumps. In order to ensure the reliability of production, all kinds of production machinery have a certain margin when they are designed and equipped with power drives.
-
06/13/2020
Screw refrigeration compressors are prone to these types of failures, have you ever encountered them
1. Fault type 1. Abnormal compression ratio 2. Low condenser efficiency and failure 3. Low evaporator efficiency and failure 4. Failure of the oil system 5.Electrical failure
-
04/10/2024
Servo Control, Step Control and Variable Frequency Control: Detailed Explanation of the Three Major Controls
The following introduces the working principle, structure, types and application of the three major control methods of servo, step and variable frequency.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/27/2020
World Compressor Market Overview of the Compressor Market Oil-free technology
Compressors using oil-free technology have attracted more and more attention in the global market because they reduce operating and maintenance costs and are an energy-saving product.
-
06/28/2020
Compressor-Hitachi 3p cold storage compressor
Compressor-Hitachi 3p cold storage compressor How to distinguish the big feet of Guangzhou Hitachi inverter fixed frequency compressors? The busier the production, the more problems. Recently, many customers are asking us if Guangzhou Hitachi Inverter Fixed Frequency Compressor still has big foot machine and small foot machine? How to distinguish?
-
07/27/2020
The refrigerator compressor keeps beeping after cleaning, but it is not cooling. What's the problem?
he compressor keeps ringing, so it keeps working. There is no intermittent start and stop sound, which means it has been working hard to refrigerate, but now there is no refrigeration output.
-
06/13/2020
Cold storage system composition control and operation process
Cold storage system composition control and operation process 1. Composition of small cold storage system As shown in the figure, the figure is a refrigeration device composed of a cold storage, mainly including: refrigeration compressor, chiller, therm 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ
-
08/11/2020
The name of each part of the cold storage
Compressor: It acts to compress and drive the refrigerant in the refrigerant circuit. The compressor extracts the refrigerant from the low-pressure zone, compresses it, and sends it to the high-pressure zone for cooling and condensation.
-
11/24/2022
What is Visual Flame Detector?
On the basis of traditional flame detectors, image-type flame detectors combine intelligent camera control technology and intelligent image processing technology.