Series | MCQV2 Series |
Acting type | Double acting / Male thread |
Tube I.D. (mm) | 32 |
Stroke (mm) | 350 |
Proof pressure | 1.5 MPa |
Medium: Air
Code 11: Double acting / Male thread
Operating pressure range: 0.05-1 MPa
Proof pressure: 1.5 MPa
Ambient temperature: -5 degrees-+60 degrees(No freezing)
Available speed range: 50-500 mm/sec
Sensor switch: RCA
Sensor switch holder: HV1, HV2, HV3
MINDMAN Air Cylinder MCQV2-11-32-350M
People who bought this item also viewed
NEW-ERA Air Cylinder PXY-SD12-1-LF
CHANTO Air Cylinder MSR32X75
Compact Air Cylinder SD34X12
AirTAC Air Cylinder SC40X70
MINDMAN Air Cylinder MCJQ-12-32-25M
MINDMAN Air Cylinder MCJA-12-32-20
MINDMAN Air Cylinder MSBD-50-30-M-K
Festo Air Cylinder ADN-63-10-I-P-A
Festo Air Cylinder DSNU-16-200-P-A
Festo Air Cylinder DSN-20-10-P
SHAKO Air Cylinder IC63B300
LS Mecapion Encoder S48-8-2500VL
UNIVER Solenoid Valve AI-3501
Belimo Actuator LF120
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Yuci Vane Pump YYB-AB9-92B-DF-50
Broyce Relay 45226
Recent related posts
-
07/17/2020
How to clean the central air conditioning system
Many companies need the central air conditioner of the all-in-one machine to cool the equipment. If the equipment takes a long time or if one of the accessories in the system is broken, we need to replace it. If the equipment is used for a long time, many impurities will remain in the system.
-
08/02/2020
Which type of refrigerant is generally used for household air conditioners
At present, due to global warming, people use air conditioners more and more frequently, but not all users are familiar with the types and use of air conditioner refrigerants.
-
01/21/2024
Central Air Conditioning: Types, Components, and Brands (including Mitsubishi Electric, Daikin, York, Carrier, etc.) (Part 2)
The air conditioning system was first invented by Willis Carrier, the founder of Carrier Company. The technology gradually spread in America and Europe.
-
02/27/2021
Debugging method of servo motor
Before wiring, initialize the parameters. On the control card: select the control method; clear the PID parameters; let the default enable signal turn off when the control card is powered on; save this state to ensure that the control card is in this state when it is powered on again.
-
06/16/2023
How to Reset a Refrigerator Compressor: a Step-by-Step Guide
If your refrigerator is not cooling properly or is making strange noises, it may be time to reset the compressor.
-
09/10/2020
Existing problems in the promotion and application of water source heat pumps in my country
As a new type of cooling and heating method, water source heat pump should be quite mature and no problem from a technical point of view, especially from the point of view of heat pump units. However, considering China's national conditions and the promotion and application of water source heat pump cooling and heating as a whole system, there are still some problems:
-
06/13/2020
The common oil shortage failures of scroll refrigeration compressors are here
The compressor has been short of oil for a long time-the mechanism and the friction pairs are overheated, resulting in bearing sintering and shaft holding. The compressor is short of oil for a short time-the mechanism and the friction pairs are abnorma 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦
-
08/15/2020
Steps to determine the cause of the failure of the thermal expansion valve
1. When the refrigerant of the refrigeration system leaks completely, or there is no refrigerant flowing through the thermal expansion valve due to other reasons, the valve body of the thermal expansion valve will not be frosted.
-
08/11/2020
The temperature status and faults of the unit components of various commercial central air-conditioning systems
When the commercial central air-conditioning system is overhauled, temperature inspection and testing are very important, because the unit components of the entire central air-conditioning system have a normal temperature range, beyond which it is an abnormal state.
-
12/02/2021
Use of Differential Pressure Transmitter and Common Troubleshooting
Differential pressure transmitter is a kind of pressure measuring instrument widely used in all kinds of chemical industry.