06/13/2020
Heating principle
Heating principle
-
06/29/2020
Causes of non-condensable gas in refrigeration system
Causes of non-condensable gas in refrigeration system 1. Insufficient emptying of the refrigeration system before charging the refrigerant Before charging the refrigerator, the compressor cylinder in the refrigeration system, the condenser, the evaporator, and the piping of the system were filled with air. In order to eliminate these air before charging the refrigerant, the interior of the refrigeration system Vacuuming,
-
07/15/2022
What is a Gear Pump
Gear pump is a rotary pump that transfers liquid or pressurizes it relying on the change and movement of the working volume formed between the pump cylinder and the meshing gear.
-
08/19/2020
5 common causes of refrigeration system failures and solutions
1. The suction temperature is too high-mainly caused by the increase of suction superheat. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam.
-
07/23/2020
The damage of air-conditioning refrigeration compressor and its preventive measures
An 82000DWT bulk carrier of a shipping company broke down on the 7th day after leaving the factory. The crew described that when it started, the air-conditioning refrigeration compressor could not run continuously, and a large current occurred and an alarm was triggered.
-
09/04/2020
Factors affecting the use of oil-free air compressors
The oil-free air compressor is the main body of the air source device. It is a device that converts the mechanical energy of the prime mover into gas pressure energy and is a pressure generating device for compressed air. The factors that affect its use are:
-
08/08/2020
Daily maintenance method of precision air conditioner for computer room
With the development of science and technology, the precision air conditioners in the computer room are gradually upgraded, and the cost is getting higher and higher. Therefore, it is more necessary to increase maintenance efforts.
-
07/23/2020
Analysis of common failure causes of hermetic refrigeration compressors
1. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.<br></br>
-
09/14/2020
Several PTA equipment process routes and equipment air compressor technology
PTA is the abbreviation of Purified Terephthalic Acid. PTA is the basic material for the production of polyester fiber and packaging industry, and the main raw material for the chemical fiber industry.
-
12/01/2021
Calibration of Rosemount Transmitter