Family Name | MINAS A6 |
Series | MSMF Series |
Special Order Product | Special Order Product |
Type | Low inertia |
Product | Servo Motor |
Voltage (V) | 200 |
Rated output (W) | 400 |
Rated rotational speed (r/min) | 3000 |
Rated rotational Max. speed (r/min) | 6000 |
Rated torque (N ⋅ m) | 1.27 |
Momentary Max. peak torque (N ⋅ m) | 3.82 |
Moment of inertia of rotor [x10-4 kg ⋅ m²] | 0.30 |
Recommended moment of inertia ratio of the load and the rotor | 30 times or less |
Flange sq. dimension (mm) | 60 mm sq. |
Motor encoder connector | Lead wire |
Rotary encoder | Specifications |
Shaft | Key-way, center tap |
Holding brake | with |
Oil seal | with |
Enclosure | IP65 |
Panasonic Servo Motor MSMF042L1V2M
People who bought this item also viewed
Yaskawa Servo Motor SGMAS-12A2A4B
Allen Bradley Servo Motor 8500-A2D-K1B
Fuji Servo Motor GYS751D5-RC2
Panasonic Servo Motor MSMA3AZA1N
Panasonic Servo Motor MHMJ082G1U
Panasonic Servo Motor MSM042A1B
Panasonic Servo Motor MSMA202P1G
XINJE Servo Motor MS-80STE-M02430B-20P7
Yaskawa Servo Motor SGMAV-C2ADA21
Allen Bradley Servo Motor MPL-A330P-MJ24AA
ABB Servo Motor 3HAC021456-001/04
Lenze Servo Drive E82EV302-4C
SIEMENS Actuator SKD60
COSEL Power Supply PBA150F-5-CRN
LG LS PLC Special module XGF-SOEA
DAYTON Speed Reducer 6K351
MITSUBISHI Spindle Amplifier MDS-DM2-SPV2-10080
Winyao NIC Card WYX540T2-POE
EMERSON Controller Module SE3008
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder ADNM-125-A-P-A-40Z1-90Z2
GE Circuit Breaker FDN36TD032ED
OKTY Oil Seal TC(FKM)55*90*10
BLAUBERG FAN Vento Expert A85 Wi
Recent related posts
-
08/21/2020
Useless for a lifetime. Dehumidification and refrigeration of air conditioners are completely different!
This summer, the heavy rain that has come in New York caught many friends off guard, and the humid and sultry weather made the big guys complain. A small partner told the author that at this time, dehumidification is enough. The air conditioner does not need to be cooled. principle of refrigeration of central air-conditioning chillers
-
08/19/2020
Multi-line system characteristics and common faults
Multi-connection is commonly known as "one-to-many". A multi-connection system is an outdoor unit connected to multiple indoor units, and each indoor unit can be freely run/stopped, or grouped, or centralized.
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
01/15/2021
Danfoss extends its Turbocor® training and support resources with 12 new e-lessons
Danfoss has released new online training materials for technicians working with its Turbocor® oil-free compressors—further extending the support and learning resources to help users and OEMs maintain long-lasting performance.
-
08/17/2020
Drainage method of refrigeration pipe during cold storage installation
Before the cold storage is installed, the refrigeration pipe must be thoroughly removed. The rust and dirt on the inner and outer walls of the pipe must be removed, and the inner wall must be kept dry.
-
06/13/2020
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass"
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass" The energy regulation of the system is generally composed of the following ways: Compressor parallel-multi-stage contro 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
08/15/2020
The main cause of cold storage fire is cold storage installation or cold storage construction
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.
-
02/14/2022
Factors Affecting Service Life of the Air Compressor Oil
Maintaining the air compressor oil is critical to the compressor’s performance.
-
09/09/2020
How to provide air source for air compressor
Is the air compressor better for centralized air supply or more energy-saving for point-by-point air supply; for equipment with small air consumption and low pressure, it may be economical to install a pressure reducing valve to work.
-
07/02/2020
How important is the air conditioning compressor for air conditioning
How important is the air conditioning compressor for air conditioning As the earth we live in enters summer, the summer in many places is uncomfortably hot, so a good summer cool companion to accompany them is-air conditioning. Air conditioning has become a good weapon for us to spend the summer.