Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.5 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.35...0.5 A |
Suitable for induction motors with P | 0.12 kW |
Instantaneous overcurrent releases | 6.5 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.232 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.35...0.5 A
N-release 6.5 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.35 - 0.5
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.5 A
operating current
at AC-3 at 400 V rated value 0.5 A
operating power at AC-3
at 230 V rated value60 W
at 400 V rated value120 W
at 500 V rated value180 W
at 690 V rated value2500 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 6.5 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.5 A
at 600 V rated value0.5 A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-0FA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV2021-1EA10
Siemens Circuit Breaker 3RV1011-0BA10
Siemens Circuit Breaker 3RV1011-1CA15
Siemens Circuit Breaker 3RV1021-4DA10
Fuji Circuit Breaker BB3AEAC-020
Siemens Circuit Breaker 3RV1021-1BA10
TRIAD Transformer F-326X
Siemens Contactor 3RA2423-8XF32-1AC2
CITEL Surge Protection Device DS41S-320
Delixi Fuse RS0-200
HONGFA Relay HFV15-12-Z1T-R(136)
EPCOS Resistor B72660M0271K072
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KCL Vane Pump VQ425-216-18-F-RAAA-02
Recent related posts
-
06/18/2020
Why does the return air inlet of the refrigeration compressor of the high and low temperature alternating humidity and humidity test chamber frost
Why does the return air inlet of the refrigeration compressor of the high and low temperature alternating humidity and humidity test chamber frost High and low temperature alternating humidity and humidity test chamber refrigeration compressor frost retu 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧є 識 �僬
-
07/24/2022
4 Common Causes of Water Pump
Most people know that a water pump is important to vehicle operation, but not everyone knows the four most common causes of water pump failure.
-
03/02/2021
Voltage of servo motor: relationship between voltage and speed of servo motor
1)At high speed, the speed is proportional to the voltage 2) At low speed, the voltage is lower than the decrease of speed;
-
07/04/2020
In the post-new crown era, what are the market opportunities for refrigeration companies
In the post-new crown era, what are the market opportunities for refrigeration companies When we thought that the fear and anxiety caused by the new crown epidemic were going away, when we set up stalls in full swing to prepare for the development of the night economy, the small-scale counterattack of the new epidemic in Beijing made the originally slightly relaxed nerves tense again.
-
09/12/2022
Differences between Circuit Breaker and Isolator Switch?
A circuit breaker refers to a switching device that can close, carry and break current under normal circuit conditions and can do the same under abnormal circuit conditions within a specified time.
-
01/07/2022
How to Check and Replace Refrigerator Compressor Relay
If your refrigerator has been in use for some time, there may be some faults with the compressor. To troubleshoot the compressor, check whether there is abnormal noise or overheating phenomenon in the relay.
-
08/11/2020
The role of these parts in cold storage construction
Speaking of cold storage, we must all know that in the field of food in our daily life, it brings us not only convenience in life, but also health and safety. Everyone knows that any piece of equipment will need a lot of large and small parts,
-
07/07/2022
Tips for Troubleshooting Hydraulic Proportional Valves
The components of a proportional valve are few; the spool, solenoid, and linear variable differential transformer, or LVDT. In order to operate the valve, a power supply and amplifier are needed.
-
07/03/2020
High Pressure Hydrogen Compressors Market Trends Analysis, Top Manufacturers, Shares, Growth Opportunities, Statistics & Forecast to 2026 | ARIEL, Atlas Copco, Burckhardt
The dramatic spread of COVID-19 has created a marginal impact on the global air compressor market. The sustainability of the air compressor market is mainly attributed to the significantly increasing demand from various industries such as oil & gas, healthcare, chemical manufacturing, and many others.
-
01/07/2021
Working principle of air conditioner refrigerator
Working principle of air conditioner refrigerator The basic principle of HVAC chiller using refrigeration For example, the kind used in the laboratory or industrial environment, there are many types of chillers on the market, this is an overview of 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ