Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 25 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 20...25 A |
Suitable for induction motors with P | 11 kW |
Instantaneous overcurrent releases | 325 A |
Short-circuit breaking capacity | 50 kA |
Weight approx. | 0.364 kg |
Circuit breaker size S0 for motor protection CLASS 10 A-release20...25 A Short-circuit release 325 A
Screw terminal Standardswitching capacity !!! Phased-out product !!! Successor is SIRIUS3RV2 Preferred
successor type is 3RV2021-4DA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 10.5 W
at AC in hot operating state per pole 3.5 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20
mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 25 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 20 -25A
operating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 25 A
operating power at AC-3
at 400 V rated value 11000 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 10 kA
at AC at 690 V rated value 4 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Siemens Circuit Breaker 3RV1021-4DA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV2011-0KA20
Siemens Circuit Breaker 3RV1021-0AA10
Siemens Circuit Breaker 5SY4325-7
Siemens Circuit Breaker 5SL6140-7CC
Siemens Circuit Breaker 3RV1011-0HA10
ABB Circuit Breaker GSN201 C10 AC30
Schneider Circuit Breaker A9F18106
Schneider Transformer ABL6TS25G
Ferraz Shawmut Fuse D01GR44V4
KEYENCE Relay KV-RC16BT
EPCOS Resistor B59750C120A70Z15
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Bosch Rexroth Servo Drive BZM01.3-01-07
AirTAC Air Cylinder JSID125X25S
IXYS Rectifier Module MDD56-14N1B
Ebmpapst Fan A4E300-AP26-70
SHAKO Air Cylinder JC20B20-H
Omron Switch D4N-4F32
Recent related posts
-
08/19/2020
How to distinguish inferior refrigerants What effect does refrigerant purity have on the system
Inferior refrigerants will affect the performance and stability of the system, and more seriously will cause damage to system components and compressors. The following methods can be used to distinguish whether it is a low-quality refrigerant:
-
11/27/2023
CPU Fan Replacement HP Laptop with Figures and Detailed Steps
Recently, the HP notebook for personal use prompts that the fan is broken when it is turned on. I decisively placed an order online and bought a replacement fan.
-
09/02/2020
The installation standards and requirements of the air compressor are indeed in place in detail!
1 Installation environment layout requirements In order to meet the needs of development, the computer room should have room for expansion in the position of the general map.
-
09/15/2020
Pt100, thermocouple integrated temperature transmitter
Pt100, thermocouple integrated temperature transmitter The temperature measuring probe adopts Pt100 platinum resistance, J, K, E, thermocouple, high precision and good stability
-
07/17/2020
Cold storage installation and cold storage installation selection
First, the cold storage installation should pay attention to the following: the type of cold storage 1, according to temperature: A, high temperature cold storage (plus or minus 5 degrees Celsius): suitable for fruit and vegetable preservation; B, medium temperature cold storage (minus 10 degrees-minus 5 degrees):
-
09/07/2020
The air compressor lubricant is not up to standard
Air compressor lubricating oil is of great significance to the normal operation of screw air compressors, and it has a great impact on the reliability, economy and service life of the air compressor.
-
08/16/2020
What to pay attention to when the refrigeration equipment is moved
Because the company needs to change the working environment, all the equipment of the company must be moved, and the refrigeration equipment in the disassembly and installation process requires staff with rich professional knowledge,
-
09/08/2020
What environment will affect the operation of the air compressor
The surrounding environment of the air compressor will also have a significant impact on the operation of the air compressor. The following phenomena are mainly caused by the analysis of the cause of the failure caused by the bad surrounding environment, so the user should try to meet the standard requirements when installing the air compressor to deal with the surrounding environment .
-
01/11/2021
Mitsubishi Electric Home Central Air Conditioner-The King of Home Central Air Conditioning With the development of the air-conditioning market
Mitsubishi Electric Home Central Air Conditioner-The King of Home Central Air Conditioning With the development of the air-conditioning market, many companies have entered the field of air-conditioning, resulting in more and more air-conditioning brands, 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ә 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/01/2023
How Does a Ductless Heat Pump Work? A Comprehensive Guide
If you're looking for an efficient and flexible heating and cooling solution for your home, a ductless heat pump may be just what you need.