There is no price at present, you can Request a Quote
Circuit breaker 5 a release 3.5 ... 5 A A n release 65 A, used for motor protection, etc
Class 10, threaded connection, standard exchange capacity
Product brand name SIRIUS
Product Name Circuit Breaker
Product specifications are used for motor protection
Product type name 3RV6
Comprehensive technical data
Structural dimension S00 of circuit breaker
The loss power W totals 6 W typically
The measured value is 690 V at AC when the pollution degree of isolation voltage is 3
The measured value of impulse voltage resistance is 6 kV
Protection level IP
IP20 on the front
connection terminal IP20
dent resistance
comply with IEC 60068-2-27 25g/11 ms
environmental conditions
The installation height is higher than the horizontal plane
the maximum value is 2 000 m.
Ambient temperature
-20 ...+60 c during operation
-50 ...+80 C during transportation
Relative air humidity during operation 10 ... 95%
main circuit
The number of poles is used for the main circuit 3
Settable current action value 3.5 ... 5 A of overload tripping of current control
Working voltage
the measured value is 690 V
the maximum measured value is 690 V at AC-3
The measured working frequency is 50 ... 60 Hz
The measured working current is 5 a.
Working current
AC-3 AC-3
the measured value is 5 A at 400v
Switching frequency
the maximum value at AC-3 is 15 1/H.
Protection and monitoring functions
Trip level CLASS 10
Over-current release specification heat
Working short circuit current (Ics) breaking capacity AC
the measured value at 400v is 100 kA
Breaking capacity of limit short circuit current (Icu)
the measured value at 400 V at AC is 100 kA
Current action value
65 A of short circuit release without delay
Protection device to prevent short circuit from causing damage to switching device.
Product function short circuit protection yes
Specification of short circuit release magnetic
Mounting/fixing/outline dimensions
The loading position is arbitrary
Fastening type: screw fastening and snap fastening on 35mm mounting rail according to DIN EN 60715
Height 97 mm
Width 45 mm
Depth 96 mm
Siemens Circuit Breaker 3RV6011-1FA10
There is no price at present, you can Request a Quote
People who bought this item also viewed
Fuji Circuit Breaker EW50RAGU-3P010
Siemens Circuit Breaker 3RV1031-4FA10
Siemens Circuit Breaker 3RV2021-4CA15
Fuji Circuit Breaker EW250JAGU-3P150
Siemens Circuit Breaker 5SY4332-7
TRIAD Transformer F-148XP
Schneider Contactor LC1D18M7
OBO Surge Protection Device MCD 50-B3+NPE
Ferraz Shawmut Fuse PC44UD70V30CP1
Nais Relay AQY212GHAX
UniOhm Resistor 25121WJ0102T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
GE Input Output Module IC693ALG391
NLP Level Meter LG-200
MAC Solenoid Valve 55B-12-PI-591JJ
Panasonic Relay AQY216EH
Recent related posts
-
06/13/2020
A complete list of technical solutions for maintenance of screw refrigeration compressors
A complete list of technical solutions for maintenance of screw refrigeration compressors Screw refrigeration compressor is the core component of the refrigeration system. Whether the unit is running well is directly related to safety and energy consumpt 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂
-
12/23/2020
Compressed air can also generate electricity
Compressed air can be used to generate electricity, and after the heat generated during the power generation process is recovered, it can also be used for heating. The reporter learned from the Chongqing Science and Technology Commission that Chongqing Jingtian Energy Investment (Group) Co., Ltd.
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.
-
06/13/2020
Working principle of York screw compressor
Working principle of York screw compressor Working principle of York screw compressor, screw compressor is a volumetric compression machine with working volume for rotary motion. The compression of gas depends on the change in volume, and the change in v 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ
-
06/15/2020
Reasons for refrigerator compressor not working
Reasons for refrigerator compressor not working Reason one: Is the external power supply and compressor input voltage normal? Check whether the power supply and compressor input voltage meet the standard requirements (187 volts to 242 volts), whether 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦
-
06/20/2020
Working principle of reciprocating piston compressor_Characteristics of reciprocating piston compressor
Working principle of reciprocating piston compressor_Characteristics of reciprocating piston compressor <img src="{{media url="wysiwyg/Working_principle_of_reciprocating_piston_compressor.jpg"}}" alt="" /> Reciprocating piston compressor Positive compressor that changes the internal volume of the compression chamber by one or several reciprocating pistons.
-
03/24/2023
Working Principles of Common Vacuum Pumps
The vacuum pump is a device that vacuumizes the pumped container under the action of electromagnetic force to maintain the vacuum. Vacuum pumps are usually widely used in low temperature equipment, papermaking machinery, vacuum equipment, and petroleum, mining, foundation treatment and other fields.
-
06/15/2023
Freezer Compressor Hot: Causes and Solutions
A freezer/refrigerator is an essential appliance in most households, used to store food at low temperatures to preserve its freshness and quality.
-
05/02/2023
The Difference between Hermetic and Semi-Hermetic Compressors
The compressor is the primary equipment in the refrigeration system. It converts electrical energy into mechanical energy, compresses low-temperature and low-pressure refrigerant gas into high-temperature and high-pressure gas, and ensures the cycle of refrigeration.
-
03/21/2024
The Development History and Trends of Servo Systems
The servo system has experienced the development process from hydraulic, pneumatic to electrical. At present, the most widely used is the electrical servo system.