Siemens Circuit Breaker 3VU1640-1MR00 36...52 A for motor and line protection
with screw terminal Icu: 415 V 35 kA auxiliary contact: 1 NO + 1 NC
Siemens Circuit Breaker 3VU1640-1MR00
People who bought this item also viewed
Siemens Circuit Breaker 5SY5263-7CC
Siemens Circuit Breaker 3RV2021-0HA10
Siemens Circuit Breaker 3RV2021-1DA10
Siemens Circuit Breaker 3RV6011-1AA15
Terasaki Circuit Breaker TZ50CC
Siemens Circuit Breaker 3RV5341-4JC10
CHINT Transformer NDK(BK)-25
TENGEN Contactor TGC1-3201 110V
DEHN Surge Protection Device DG S 440
Littelfuse Fuse 0448002.MR
HONGFA Relay HFKM-012-SHST
UniOhm Resistor 1210W2J0100T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Dwyer Switch 3010MRS
Fanuc Servo Motor A06B-0033-B075
Siemens Transmitter 7ME6580-3MC14-2AA1
TYCO Relay 3SBC1393A2
FULOS Air Cylinder MGPM16-175
Saginomiya Expansion Valve ATX-71140DHG
HONGFA Relay HF2150-1A-24DE
Recent related posts
-
07/15/2020
ZP725KCE-TWD60 HP 50Hz air conditioner Emerson Copeland compressor
Today's editor will introduce the Emerson Copeland compressor ZP725KCE-TWD, which is suitable for R410A refrigerant at 50Hz single-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 60 hp. Other technical parameters can be downloaded from our company's website for inquiries.
-
09/15/2020
85 pool water level sensor, field lightning protection transmitter
Sensor, field lightning protection transmitter okmarts.com pressure sensor, okmarts.com pressure transmitter, okmarts.com pressure sensor PTH601 uses diffused silicon piezoresistive core or ceramic piezoresistive core, 316 stainless steel structure, mainly suitable for rivers, groundwater levels, reservoirs, water towers and containers, etc. liquid level measurement and control.
-
08/04/2020
What is the difference between central air conditioning and fresh air system Understand in one article
A few years ago, central air-conditioning and fresh air systems were only high-end home improvement options in some villa areas. Now they have become the decoration s* options for most families.
-
08/21/2020
What are the advantages of using economizers for screw chillers
1. What is an economizer Economizers are often used in secondary air screw compressor refrigeration systems. Under working conditions with relatively low evaporation temperatures (below -25°C), the efficiency of ordinary single-stage screw compressors decreases,
-
06/14/2020
Rolling rotor compressor structure
Rolling rotor compressor structure
-
02/24/2020
What is the problem with the poor cooling effect of the air conditioner
In the hot summer, I believe that many people can not do without air conditioning, air conditioning can allow us to spend this summer in a cool environment. However, in the process of using air conditioners, I believe that many people have encountered a situation where the cooling effect of the air conditioner is not good, so why is the cooling effect of the air conditioner not good? What needs to be solved.
-
07/14/2020
Teach you 10 self-cooling drinks, do it whenever you want
1. First cut the oranges and lemons into small corners, this is not a big deal, just put it in a glass. 2. The orange and lemon corners are accumulated in the glass. There will be juice on one side and fragrance oil in the peel on the other side, so if you squeeze it under the mouth of the cup, the aroma will be much stronger.
-
07/01/2020
Three major causes of compressor cracks in winter
Three major causes of compressor cracks in winter When using the compressor in winter, we may encounter some problems, such as cracks in the compressor body. There are many ways to cause cracks in the compressor. After summing up, the specifics can be summarized as the following three points:
-
06/14/2020
Common air conditioning host
Common air conditioning host 1. Water-cooled chiller The water-cooled chiller belongs to the refrigeration unit part in the central air-conditioning system. Its refrigerant is water, which is called the chiller, and the cooling of the condenser is r 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ
-
09/03/2022
How to Maintain Circuit Breaker?