Rated Operational Voltage:
Main Circuit 208 ... 600 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V
Rated Control Circuit Voltage (Uc):
DC Operation 24 V
Rated Frequency (f):
Main Circuit 50/60 Hz
Rated Operational Power - In-Line Connection (Pe):
(400 V) 22 kW
Rated Operational Current - In-Line Connection (Ie):
45 A
Rated Operational Power - Inside Delta Connection:
at 400 V 37 kW
Rated Operational Current - Inside Delta Connection:
76 A
Service Factor Percentage:
100 %
Overload Protection:
Build-in electronic overload protection
Integrated Electronic Overload:
Yes
Adjustable Rated Motor Current Ie:
30 ... 100 %
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 %
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0...10 V, 0...20 mA, 4...20 mA
Signal indication ready to start/standby ON (LED):
Green
Signal indication running R (LED):
Green
Signal indication protection (LED):
Yellow
Signal indication fault (LED):
Red
Communication:
Built in Modbus interface, Anybus, FieldBusPlug (with adapter).
Terminal Type:
Cable Clamp
Connecting Capacity Main Circuit:
Hole Diameter 8.5 mm
Connecting Capacity Control Circuit:
Rigid 1x2.5 mm^2
Connecting Capacity Supply Circuit:
Rigid 1x2.5 mm^2
Tightening Torque:
Main Circuit 8 N.m
Product Main Type:
PSTX45
Environmental
Ambient Air Temperature:
Storage -40 ... +70 Celsius Degree
Operation -25 ... +60 Celsius Degree
ABB Soft Starter PSTX45-600-70
People who bought this item also viewed
ABB Soft Starter PSE142-600-70
ABB Soft Starter PSE370-600-70
ABB Soft Starter PSTB370-600-70
ABB Soft Starter PSR85-600-70
ABB Soft Starter PSR16-600-70
Siemens Soft Starter 3RW4426-3BC44
ABB Soft Starter PST175-690-70
ABB Soft Starter PSE85-600-70
Lenze VFD Frequency Converter EVS9326-ES
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
OKTY Oil Seal TC(NBR)220*260*16
Fuji Belt XPA-1557
MAC Solenoid Valve 6322D-331-PM-RA11
Omron Sensor E2V-X2C1
Recent related posts
-
01/11/2021
About Mitsubishi Electric (Guangzhou)
About Mitsubishi Electric (Guangzhou) Mitsubishi Electric (Guangzhou) Compressor Co., Ltd. (abbreviated as MGC) is a wholly-owned Japanese enterprise jointly established by Mitsubishi Electric Corporation, Mitsubishi Electric (China) Co., Ltd. and Mitsub 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ޒ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/17/2020
What are the three tubes of refrigerator compressors used for
What are the three tubes of refrigerator compressors used for 1. The general refrigerator compressor has three pipe ports; 2. The exhaust port discharges the compressed refrigerant to the condenser and then dissipates heat. The temperature of th 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋ
-
10/12/2021
What are the Major Causes of Variable Frequency Drive (VFD) Damage?
The larger the setting value, the higher the gain and the greater the stiffness. Under the same frequency command pulse condition, the position lag will be smaller.
-
11/10/2022
3 Common Expansion Valve Failures and the Solutions
The most common failures in the use of expansion valves are valve blockage, frosting, ice blockage and oil blockage.
-
02/29/2024
Freezer Fan Not Working: Common Reasons and Troubleshooting Steps
A malfunctioning freezer fan can be a source of frustration for anyone relying on their freezer to keep food items fresh and properly preserved.
-
02/21/2024
Wall Hung Condensing Boilers: Everything You Need to Know
Wall-hung boilers (for radiator heating or floor heating and water heating) have become the first choice of heating equipment for more and more families.
-
09/15/2020
Comparison of scroll compressor and rolling rotor compressor
With the development of society, human beings have higher and higher requirements for the comfort of the living environment. Therefore, improving the compression efficiency and working reliability of the compressor, developing and applying material-saving and energy-saving compressors have become one of the main directions for the development of refrigeration technology.
-
08/11/2020
Selection of cold storage electrical control system and other design considerations
Selection of cold storage electrical control system and other design considerations<br></br> The refrigeration electrical control system is a necessary condition to ensure that the cold storage always automatically works within the set range. Its main work flow includes:
-
06/22/2020
Causes and judgement of centrifugal compressor surge
Causes and judgement of centrifugal compressor surge Causes of centrifugal compressor surge ①Flow<img src="{{media url="Causes_and_judgement_of_centrifugal_compressor_surge.jpg"}}" alt="" /> Each centrifugal compressor corresponds to a curve between outlet pressure P and flow rate Q at different speeds n, as shown in Figure 2.
-
08/23/2022
What is a Pneumatic Actuator?
The pneumatic actuator, or the pneumatic control valve actuator, is a device that uses air pressure to drive the opening and closing or regulate the valve.