Primary Voltage:115 V/230 V
Secondary Voltage in Series:56.0 V CT at 0.65 A
Secondary Voltage in Parallel:28.0 V at 1.3 A
Primary Frequency:50 Hz/60 Hz
TRIAD Transformer F56-650-C2
People who bought this item also viewed
Honeywell Transformer Q624A1014
CHINT Transformer JBK3-160
Eaton Moeller Circuit Breaker NZMN1-A100
Eaton Contactor XTCG018C00B0
CITEL Surge Protection Device DS43S-120
Ferraz Shawmut Fuse FR22AM69V4P
Pilz Relay 750110
UniOhm Resistor 0805W8J0274T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder ADN-20-40-A-P-A
LG LS PLC G6F-POPA
HENGYI Vane Pump SVQ45-237-F-RAL-01
Festo Air Cylinder ADN-40-30-I-PPS-A
MINDMAN Air Cylinder MCMB-27-25-300
Recent related posts
-
08/12/2021
How to Test a Refrigerator Compressor?
Refrigerators are very common in our daily life. Most people know how to use refrigerators, but they do not know the relevant knowledge.
-
03/16/2022
What’s the Difference between Thermoelectric and Compressor Wine Coolers?
When it comes to the wine cabinet, it is very familiar to us, and some families have one. How much do you know about the wine cabinet?
-
09/04/2022
Types of Stepper Motors: Three Methods to Classify
Stepper motor uses electronic circuits to convert direct current into a multi-phase sequence-controlled current, and to supply power to coils at different times.
-
07/23/2020
Reasons for excessively high discharge temperature of refrigeration compressor (technology sharing)
The refrigeration compressor is the core and heart of the refrigeration system. The capacity and characteristics of the compressor lead to the capacity and characteristics of the refrigeration system. In a sense, the design and matching of the refrigeration system is to reflect the capacity of the compressor.
-
07/21/2022
How to Prime a Water Pump
Water pumps will run out of pressure and stop working if turned off for an extended period of time, such as over the winter.
-
01/10/2023
5 Refrigeration Solenoid Valve Failures and the Solutions
Refrigeration solenoid valve is an industrial equipment controlled by solenoid. It adjusts mass direction, flow, speed and other parameters in industrial control systems.
-
06/30/2020
How to deal with the faulty host refrigerant system of the compressor
How to deal with the faulty host refrigerant system of the compressor How to deal with a main engine refrigerant system where the compressor has burnt out or failed is a more serious and technically demanding problem than the production of a new main engine. However, it is often neglected by most of the technicians, and even the wrong concept is replaced if they think that it is broken anyway! It causes some disputes that the compressor quality is poor or others use it improperly.
-
03/09/2021
Servo driver related parameter setting method
Position feedforward gain: set the feedforward gain of the positioning loop. The larger the set value is, the smaller the position delay isand the larger the feedforward gain of the position loop is, the high-speed response of the control system will rise, but the position of the system is unstable and prone to oscillation. When high response characteristics are not required, this parameter is usually set to 0, indicating the range of 0 ~ 100%.
-
07/02/2020
Introduction of the models such as the MT-100 and other hermetic compressors
Introduction of the models such as the MT-100 and other hermetic compressors The picture shows the fully enclosed compressor MT-100, which is installed by the customer. Meiyou Le Maneurop hermetic compressor detailed introduction;
-
06/14/2020
Liquid Refrigerant, Dense Vapors Can Damage Compressors
To prevent these conditions