Rated flow:40l/min
XIAOLI Overflow Valve YF-L10H4
People who bought this item also viewed
REXROTH Overflow Valve DB10-2-52/200
TOYOOKI Overflow Valve HRU3ー80G*K(D)ー04
SMC Proportional Valve ITV2050-31F2BS3
KOMPASS Check Valve MCW-03-B
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CS FLUIDPower Solenoid Valve AD-20-N-G2
HONGYI Vane Pump 525VQ25A25-1AA20R
Siemens Transmitter 7ME6580-4HJ14-2AA2
Fuji Belt B-90
Recent related posts
-
06/13/2020
Five methods for leak detection in refrigeration systems
Five methods for leak detection in refrigeration systems The leak detection of the refrigeration system of the air conditioner includes the leak detection of components such as the refrigeration compressor, condenser, evaporator, filter drier, capillary 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔ
-
07/16/2020
Compressor overheating
The compressor is overheated, causing it to stop shortly after start-up (protector action). Please check whether it is:; Insufficient or excessive refrigerant, please fill the leak and evacuate, add enough refrigerant or release excess refrigerant. The capillary assembly (including the filter) is clogged and the suction temperature rises. Please replace the capillary assembly.
-
09/04/2020
The composition and function of the air compressor oil return check valve
The oil return check valve is composed of valve body, steel ball, steel ball seat, spring and other elements. The oil and gas mixture compressed by the main engine of the air compressor is initially separated in the oil and gas tank by centrifugal force.
-
08/13/2020
Why the air energy heat pump does not heat
It is a common phenomenon that air energy heat pumps do not produce heat. When air energy heat pumps were used in the winter of previous years, the water temperature would be insufficient.
-
03/10/2023
Advantages of Motor Soft Starter
Motor is widely applied in industry and daily life, thus people attach more importance to the starting method of motor. Generally, motor soft starter should be used when motor working power exceeds 30 kilowatts
-
06/29/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Note on the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse.
-
09/04/2022
Types of Stepper Motors: Three Methods to Classify
Stepper motor uses electronic circuits to convert direct current into a multi-phase sequence-controlled current, and to supply power to coils at different times.
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)
-
06/25/2020
How to solve if the air conditioner is not cooling
If it is not in the cooling state, we can adjust it to the cooling mode; if the dust accumulation of the air conditioner severely reduces the cooling function, we can find professional personnel to disassemble the evaporator, fan blade, and filter. Completely clean up; if it is because no refrigerant is added, then we can add refrigerant.
-
08/18/2020
Specific factors affecting the cooling effect of air conditioning
In the entire air conditioning and refrigeration system cycle process, the compressor plays a role in compressing and transporting refrigerant vapor and causing low pressure in the evaporator and high pressure in the condenser.