Type | Rotary Servo Motors |
Series | SGMG Series |
Rated Output | 11.0 kW |
Voltage | 200 V |
Serial Encoder | 8192 PPR Incremental Encoder |
Rotation Speed | 1500 RPM |
Specifications | Straight with key and tap |
Options | 90-VDC Brake |
Time Rating | Continuous |
Thermal Class | Class F |
Vibration | 15μm or less |
Withstand Voltage | 1500VAC 1 min |
Insulation Resistance | 500VDC, 10MΩ minimum |
Enclosure | Totally enclosed, self-cooled, IP67 |
Ambient Temperature | 0 to 40ºC |
Ambient Humidity | 20 to 80% (non-condensing) |
Excitation | Permanent magnet |
Drive Method | Direct drive |
Mounting | Flange-mounted |
Yaskawa Servo Motor SGMG-1AA2ABB
People who bought this item also viewed
Yaskawa Servo Motor SGMAH-01BAF41
Yaskawa Servo Motor SGM-08V314
Yaskawa Servo Motor SGMJV-02ADE6E
TECO Servo Motor 6CC401-3DEBGWAS
Fuji Servo Motor GYH202C6-TC2
Mitsubishi Servo Motor HC-MF13BLW90-S101
Schneider Servo Motor BMH1403P11A2A
Allen Bradley Servo Drive 2097-V34PR5-LM
ATOS Servo Valve DLHZO-TEZ-D-SN-NP-040-L71
Rockwell A-B HMI 6185-CAZAAZZ
Siemens PLC 7MH4900-2AA01
JSCC Speed Reducer 80GK15RT
MITSUBISHI Spindle Amplifier MDS-DM2-SPV3-10080
HAZE Battery HSC06-4.5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder SCA2-CA-50B-75-Y
ENC VFD Frequency Converter EDS2000-4T2200G
Yaskawa Servo Motor SGMP-04A314S
Beckhoff Terminal Box Module IP1502-B528
Mitsubishi Servo Motor HC-UF73-BKW92-S3
Recent related posts
-
09/06/2020
Analysis of common failures of motors and solutions
As an important power provider that is indispensable in people's production and life, electric motors will generate serious heat during use, but many times do not know how to solve them.
-
07/26/2020
The influence of temperature on refrigeration compressor
In summer, the discharge temperature of the compressor is relatively high and cannot be touched by hands. According to national standards, the exhaust temperature of the R22 refrigeration system should not exceed 150 degrees Celsius.
-
06/13/2020
Cold storage system composition control and operation process
Cold storage system composition control and operation process 1. Composition of small cold storage system As shown in the figure, the figure is a refrigeration device composed of a cold storage, mainly including: refrigeration compressor, chiller, therm 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ
-
06/13/2020
Tesla's cargo heat pump air conditioning market is waiting to take off
Tesla's "cargo" heat pump air conditioning market is waiting to take off? Not long ago, Tesla ModelY began its first delivery. Compared with Tesla's previous models, ModelY uses a heat pump air conditioning system.
-
07/18/2020
How to protect the refrigeration compressor
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
07/08/2022
What is A Mechanical Sealing
A mechanical seal is simply a method of containing fluid within a vessel (typically pumps, mixers, etc.) where a rotating shaft passes through a stationary housing or occasionally, where the housing rotates around the shaft.
-
07/16/2020
How to see if the refrigerant leaks in the high and low temperature test chamber
How to check whether the refrigerant leaks in the high and low temperature test box; the standard high and low temperature test box and the constant temperature and humidity test box are all selected by the air-cooled compressor, and the working principle is the same as that of the air conditioning refrigeration
-
09/14/2020
Common troubleshooting methods for twin screw compressors
Common troubleshooting of twin screw compressor 1. Trouble phenomenon The exhaust temperature of the unit is high (over 100 degrees) The coolant level of the unit is too low (should be visible in the oil glass but not more than half) Dirty oil cooler
-
09/14/2020
Several PTA equipment process routes and equipment air compressor technology
PTA is the abbreviation of Purified Terephthalic Acid. PTA is the basic material for the production of polyester fiber and packaging industry, and the main raw material for the chemical fiber industry.
-
09/10/2020
Application of pressure sensor in air compressor control system
Take a single screw air compressor as an example to illustrate the working principle of an air compressor. The working process of a screw air compressor is divided into four processes: suction, sealing and conveying, compression and exhaust.