There is no price at present, you can Request a Quote
voltage supply range +Vs: 10-30 VDC
current consumption max. (no load): 10 mA
nominal sensing distance Sn: 8 mm
voltage drop Vd: Less than 2 VDC
output circuit: NPN break function (NC)
output current: Less than 200 mA
Baumer Sensor IFBR 17N37T1/S14L-9
There is no price at present, you can Request a Quote
People who bought this item also viewed
Baumer Sensor CH-8501
Honeywell Sensor H7050B1018
Honeywell Sensor HT9612D3100
Banner Sensor Q23SN6RE
TAKEX Sensor GN-R40CRPN
Dwyer Transmitter 668-9
Honeywell Flame Detector C7061A1004
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Yaskawa Servo Motor SGMAS-12ACAH12C
Recent related posts
-
01/23/2024
Single Fan and Dual Fan for Household Central Air Conditioning Outdoor Unit: How to Choose?
Central air conditioning generally includes indoor units and outdoor units. For the selection of outdoor units, there are generally single fan and double fan types to choose from. So which one is better to choose?
-
08/25/2020
How to correctly take out ammonia refrigerant when repairing refrigeration parts
First, prepare all tools and emergency supplies before operation. Such as ammonia tanks or a certain number of ammonia bottles, scales, connecting pipes, fitter tools, gas masks, rubber gloves and first aid medicines.
-
04/10/2024
Servo Control, Step Control and Variable Frequency Control: Detailed Explanation of the Three Major Controls
The following introduces the working principle, structure, types and application of the three major control methods of servo, step and variable frequency.
-
07/23/2020
Do you know the causes, hazards, treatment and prevention methods of compressor liquid strike?
Liquid hammer refers to the situation in which the refrigerant liquid or wet vapor is sucked into the compressor by the compressor due to the failure or insufficient heat absorption and evaporation of the refrigerant, which is called liquid hammer.<br></br> <br></br>
-
06/28/2020
Compressor-Hitachi 3p cold storage compressor
Compressor-Hitachi 3p cold storage compressor How to distinguish the big feet of Guangzhou Hitachi inverter fixed frequency compressors? The busier the production, the more problems. Recently, many customers are asking us if Guangzhou Hitachi Inverter Fixed Frequency Compressor still has big foot machine and small foot machine? How to distinguish?
-
08/15/2020
The layout principle of Freon refrigerant pipeline
The main feature of Freon refrigerant is that it dissolves with the lubricating oil. Therefore, it must be ensured that the lubricating oil from each refrigeration compressor can return to the refrigeration compressor after passing through the condenser,
-
06/14/2020
11 common protection devices for refrigeration compressors
11 common protection devices for refrigeration compressors When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high
-
07/02/2020
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144 Pictured here: the United States US Youle MANEUROP compressor MTZ144 Product features of MTZ144: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably.
-
05/04/2023
What is Vapour Compression Refrigeration System?
Vapour compression refrigeration system (VCRS) is the most common cooling system used in modern refrigeration technology.
-
08/16/2020
What is the new refrigerant of R410A and what are its advantages in air conditioning applications
Recently, many users are familiar with the term inverter air conditioner, but do they feel strange to another term—new refrigerant? In fact, new refrigerant is just a kind of refrigerant that air conditioners must have when running.