voltage supply range +Vs: 10-30 VDC
current consumption max. (no load): 80 mA
output circuit: push-pull
output function: light/dark operate
output current: Less than 100 mA
voltage drop Vd: Less than 3.5 VDC
sensing distance Tw: 100-1750 mm
adjustment: Teach-in
Baumer Sensor OHDK 25G6912
People who bought this item also viewed
Baumer Sensor CH-8501
Banner Sensor T30UIPAQ
Honeywell Sensor 060-F508-01
Banner Sensor Q60VR3AF2000Q1
Banner Sensor OSBCV4B
E+E Transmitter EE160-HT6XXPBB/TX004M
Honeywell Flame Detector UVZ780
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ELCO Light Curtain SC4P30-1200E
Mitsubishi Compressor NE47TDNMT
PALL Filter HCY0212FKT39H
Autonics Sensor BF3RX
Recent related posts
-
07/11/2022
How to Choose an Air Compressor
Choosing an air compressor can leave you feeling lost if you don't know what to look for. That's because air compressors power a wide range of tools over a wide range of applications.
-
11/22/2021
Benefits of Rosemount Fieldbus Transmitter
It is reasonable to say that Rosemount fieldbus transmitter series can help customers reduce the overall cost of the system.
-
07/04/2020
High Pressure Hydrogen Compressors Market Trends Analysis, Top Manufacturers, Shares, Growth Opportunities, Statistics & Forecast to 2026 | ARIEL, Atlas Copco, Burckhardt
The dramatic spread of COVID-19 has created a marginal impact on the global air compressor market. The sustainability of the air compressor market is mainly attributed to the significantly increasing demand from various industries such as oil & gas, healthcare, chemical manufacturing, and many others.
-
07/16/2020
Common failures and maintenance of overload protectors for air-conditioning compressors
Overload protector of air conditioner compressor Installed between the active and passive sides of the power transmission, when an overload fault occurs (torque exceeds the set value), the torque limiter will separate, thereby effectively protecting the driving machinery and the load. Just like its name, the fundamental function of the overload protector is to protect the air-conditioning compressor.
-
08/29/2020
SPK Fluid reliable compressed air escort
SPK Fluids is a global supplier that provides highly specialized and engineered solutions, with branches in 35 countries and operations in more than 150 countries around the world.
-
08/19/2020
Installation of air conditioning and refrigeration system equipment
1. Installation preparation (1) Check and accept the equipment foundation according to the construction drawings. Measure the position and elevation of the pipeline shown, and find out the embedded parts of the support and hanger.
-
07/19/2020
The role of precision chillers in various industries
In the precision chiller, the heat absorbed from the evaporator and refrigeration compressor and in the pipeline is transferred to the surrounding medium to take away, and the refrigerant high-pressure superheated vapor recondenses into a liquid. In the cooling process of the chiller, the condenser plays a role in outputting heat energy and condensing the refrigeran
-
06/14/2020
This summer, the air-conditioning market is popular with sterilization, fresh air or a new engine for growth
This summer, the air-conditioning market is popular with sterilization, fresh air or a new engine for growth The winter air-conditioning market in 2019 ended with a price war, and then the new crown epidemic hit the offline market again.
-
01/17/2023
How does Variable Valve Timing Work?
The valve timing system of a traditional engine is a mechanical system in which the valve timing (i.e., valve opening and closing) remains unchanged.
-
07/30/2020
Do you know all about the setting of fire damper in HVAC system?
In the HVAC design, there are many types of valves for fire prevention and smoke exhaust, and the valve settings are different for different applications.