Number of Poles:
2
Number of Protected Poles:
2
Tripping Characteristic:
C
Rated Current (In):
40 A
Rated Operational Voltage:
acc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 440 V AC
Power Loss:
9.6 W
at Rated Operating Conditions per Pole 4.8 W
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 440 V
Operational Voltage:
Maximum (Incl. Tolerance) 125 V DC
Maximum (Incl. Tolerance) 440 V AC
Maximum 440 V AC
Maximum 125 V DC
Minimum 12 V AC
Minimum 12 V DC
Rated Frequency (f):
50 Hz
60 Hz
Rated Short-Circuit Capacity (Icn):
(400 V AC) 10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 25 kA
(440 V AC) 15 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 7.5 kA
Energy Limiting Class:
3
Overvoltage Category:
III
Pollution Degree:
3
Rated Impulse Withstand Voltage (Uimp):
4 kV
(6.2 kV sea level)
(5.0 kV 2000 m)
Dielectric Test Voltage:
50/60 Hz, 1 min: 2 kV
We can also provide the following models
2CCS864002R0845
2CCS864001R0135
2CCS864002R0135
2CCS864001R0165
2CCS864002R0165
S804S-B2
2CCF019916R0001
S804S-B2.5
2CCF019917R0001
2CCS864001R0205
2CCS864002R0205
2CCS864001R0255
2CCS864002R0255
S804S-B3
2CCF019918R0001
2CCS864001R0325
2CCS864002R0325
S804S-B4
2CCF019919R0001
2CCS864001R0405
2CCS864002R0405
S804S-B5
2CCF019920R0001
2CCS864001R0505
2CCS864002R0505
2CCS864001R0065
2CCS864002R0065
2CCS864001R0635
2CCS864002R0635
S804S-B8
2CCS864001R0085
S804S-B8-R
2CCS864002R0085
2CCS864001R0805
2CCS864002R0805
S804S-C0.5
2CCF019921R0001
S804S-C1
2CCF019922R0001
S804S-C1.6
2CCF019923R0001
2CCS864001R0104
2CCS864002R0104
2CCS864001R0824
2CCS864002R0824
2CCS864001R0844
2CCS864002R0844
2CCS864001R0134
2CCS864002R0134
2CCS864001R0164
2CCS864002R0164
S804S-C2
2CCF019924R0001
S804S-C2.5
2CCF019925R0001
2CCS864001R0204
2CCS864002R0204
2CCS864001R0254
2CCS864002R0254
S804S-C3
For more information,please contact us freely
ABB Circuit Breaker 10111841
People who bought this item also viewed
ABB Circuit Breaker SH201-B32
ABB Circuit Breaker 2CDS251001R0045
ABB Circuit Breaker S201M-C3DC
Siemens Circuit Breaker 3RV2021-1BA10
Fuji Circuit Breaker CP30FM-1P001
Fuji Circuit Breaker BW32SAG-2P005
CHINT Transformer JBK3-63
Siemens Contactor 3RA2437-8XF32-1AC2
Ferraz Shawmut Fuse DN000GB69V20
TAIAN Relay RHN-10/21.5K1 1.1-1.6A
Caddock Resistor MS221-3W-1%-4.7
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AVC Fan F6015R12LY
Recent related posts
-
08/20/2020
Several reasons for the poor cooling effect of air-cooled chillers
A chiller that uses a fan to exchange air to achieve the purpose of heat dissipation is called an air-cooled chiller. Based on the fact that the temperature in summer is getting higher day by day, and there is no maintenance for the chiller, then its cooling effect will definitely decrease.
-
03/16/2023
The Installation and Maintenance of Water Pump
1.Check whether the water pump motor is in good condition. 2.Good airtightness should be ensured between water pump and pipeline.
-
06/13/2020
Frequently asked questions about refrigeration compressors, do you know these
Frequently asked questions about refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
06/21/2020
What's the matter with air conditioning and cooling without heating
What's the matter with air conditioning and cooling without heating 1.First, it may be because the vents of the indoor unit and outdoor unit are blocked by something, or a lot of dust has accumulated on the filter inside the air conditioner; 2. It may be because the heat blown from the air conditioner is seriously lost; 3 2. It may be because the amount of refrigerant in the air conditioner is too small, which leads to a great reduction in the heat exchange efficiency, so that the air conditioner does not heat. <img src="{{media url="magefan_blog/What_s_the_matter_with_air_conditioning_and_cooling_without_heating3.jpg"}}" alt="" />
-
06/29/2020
Compression ratio of American Copeland compressor
-
08/19/2020
Selection and design of cold storage doors
Under normal circumstances, the cold storage door as one of the cold storage equipment only accounts for less than 10% of the entire system cost. After the entire system is put into use, it has almost become the "front" of the entire system.
-
07/29/2020
Nine refrigerant leakage locations and solutions
There are many welds on the left and right sides of the evaporator, and there may be more leaks. The leak of the newly installed air conditioner is mainly due to the poor welding skills of the employees of the air conditioner manufacturer.
-
08/20/2020
Three tips for cold storage board installation
n the refrigeration industry, cold storage panels with relatively low technical requirements have attracted a large amount of personnel and capital investment. The choice of the quality of the cold storage board is very important for the cold storage,
-
08/13/2020
New Explanation of Basic Knowledge of Small Chiller System
Small chiller: is a kind of water cooling equipment, small chiller is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure.
-
07/29/2023
Quiet Your Heat Pump: Causes and Solutions to Heat Pump Noise
Heat pumps are an excellent investment for heating and cooling your home or office. They are energy-efficient, eco-friendly and cost-effective compared to other HVAC systems. However, one of the common concerns that homeowners have is the noise generated by heat pumps.