Rated Operational Current AC-21A (Ie):
(380 ... 415 V) 200 A
(500 V) 200 A
(690 V) 160 A
(1000 V AC) 160 A
Rated Operational Current AC-22A (Ie):
(380 ... 415 V) 200 A
(500 V) 200 A
(690 V) 200 A
Rated Operational Current AC-23A (Ie):
(380 ... 415 V) 200 A
(500 V) 200 A
(690 V) 200 A
Rated Operational Power AC-23A (Pe):
(220 ... 240 V) 60 kW
(400 ... 415 V) 110 kW
(500 V) 132 kW
(690 V) 200 kW
Conventional Free-air Thermal Current (Ith):
q = 40 degrees centigrade 200 A
Conventional Thermal Current (Ithe):
Fully Enclosed 200 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
acc. to IEC/EN 60664-1 1000 V
Rated Operational Voltage:
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm):
(690 V) 30 kA
Rated Short-time Withstand Current (Icw):
for 1 s 8 kA
Motor Operational Voltage:
220 ... 240 V AC
Power Loss:
at Rated Operating Conditions per Pole 4.0 W
Pollution Degree:
3
Handle Color:
Black
Handle Type:
Direct mounted handle
Switches Operating Mechanism:
Mechanism at the End of the Switch
Distance Between Phases:
Standard
We can also provide the following models
Z6HLUTAF000A000000XX
Z6HLUTAJ200A000000XX
Z6HLUTAK200A000000XX
Z6HLUTAN200A000000XX
Z6HLUTAQ200A000000XX
Z6HLUTBA000A000000XX
Z6HLUTBB000A000000XX
Z6HLUTBC000A000000XX
Z6HLUTBD000A000000XX
Z6HLUTBE000A000000XX
Z6HLUTBF000A000000XX
Z6HLUTBJ200A000000XX
Z6HLUTBK200A000000XX
Z6HLUTBN200A000000XX
Z6HLUTBQ200A000000XX
Z6HWEQAA000A000000XX
Z6HWEQAB000A000000XX
Z6HWEQAC000A000000XX
Z6HWEQAD000A000000XX
Z6HWEQAE000A000000XX
Z6HWEQAF000A000000XX
Z6HWEQAJ200A000000XX
Z6HWEQAK200A000000XX
Z6HWEQAN200A000000XX
Z6HWEQAQ200A000000XX
Z6HWEQBA000A000000XX
Z6HWEQBB000A000000XX
Z6HWEQBC000A000000XX
Z6HWEQBD000A000000XX
Z6HWEQBE000A000000XX
Z6HWEQBF000A000000XX
Z6HWEQBJ200A000000XX
Z6HWEQBK200A000000XX
Z6HWEQBN200A000000XX
Z6HWEQBQ200A000000XX
Z6HWERAB000E000006FX
Z6HWERAE000A000000XX
Z6HWERBA000A000000XX
Z6HWERBB000A000000XX
Z6HWERBB000E000006XX
Z6HWERBB000E0GGG50XX
Z6HWERBC000A000000XX
Z6HWERBD000A000000XX
Z6HWERBE000A000000XX
Z6HWERBF000A000000XX
Z6HWERBJ200A000000XX
Z6HWERBK200A000000XX
Z6HWERBN200A000000XX
Z6HWERBQ200A000000XX
Z6HXESAA000A000000XX
Z6HXESAB000A000000XX
Z6HXESAB000A00A000XX
Z6HXESAB000A0E0040XX
Z6HXESAB000A0EE040XX
Z6HXESAB000A0EEE40XX
Z6HXESAB000E000006FX
Z6HXESAC000A000000XX
Z6HXESAD000A000000XX
Z6HXESADB00E000006XX
Z6HXESAE000A000000XX
For more information,please contact us freely
ABB Circuit Breaker 10133752
People who bought this item also viewed
Siemens Circuit Breaker 5SY5263-7CC
ABB Circuit Breaker SH201-B32
ABB Circuit Breaker SH201-D6
Fuji Circuit Breaker BW32AAG-2P010
Fuji Circuit Breaker EW32EAG-3P032
Siemens Circuit Breaker 5SL6110-7CC
TRIAD Transformer FP40-150
ALBRIGHT Contactor SW80-164L
Tyco Fuse MINISMDC200F
ABB Relay TF42-0.31
EBG Resistor UXP-350-450R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Nemicon Encoder NOC-HP1024-2MWT
ANSON Vane Pump VP5F-A4-50S
Yaskawa Servo Drive SGDA-05TF5
Recent related posts
-
06/27/2023
DIY Guide to Testing and Replacing Your Refrigerator Compressor Start Relay (Save Money and Time)
A refrigerator compressor start relay is a device responsible for starting the compressor of a refrigerator. When this component fails, the refrigerator will not cool properly, causing food to spoil.
-
09/14/2020
The exhaust temperature of the unit is high (over 100℃)
The lubricating oil level of the unit is too low (the green position should be visible from the oil level mirror);
-
06/21/2020
Composition principle of refrigeration system of refrigerator
Composition principle of refrigeration system of refrigerator Refrigerators have a larger cooling capacity than household refrigerators, and there are more refrigerants filled in the system. Therefore, a liquid storage tank is installed on the pipeline between the condenser and the filter, and a shut-off valve is installed on the tank to shut down the system for a long time. When closing the shut-off valve, the refrigerant liquid is stored in the tank.<img src="{{media url="Composition_principle_of_refrigeration_system_of_refrigerator.jpg"}}" alt="" />
-
09/07/2020
The air consumption is 10m³, what size air compressor is equipped
The air consumption in the factory is about 10 cubic meters. What size air compressor is suitable? Can I just buy an air compressor? Do I need to purchase other equipment?
-
06/14/2020
Refrigeration compressors have five major technological
Refrigeration compressors have five major technological developments around energy saving CFCs and HCFCs refrigerants that have a destructive effect on the ozone layer are phase-out substances specified in the Montreal Protocol
-
08/11/2020
Why is the duct air conditioner not a central air conditioner
Many people think that the air duct machine is also a central air conditioner. Strictly speaking, this understanding is actually wrong. Ducting machine is the abbreviation of concealed air conditioner. It can also be called air-conditioning ducting machine or ducted air-conditioning.
-
09/07/2020
Application field of air compressor
In life, many people have asked me what is an air compressor? Have you heard about air compressors? How much do you know about air compressors? Next, okmarts.com will take everyone to understand the air compressor.
-
07/05/2020
What sparks can be produced by the combined use of electronic expansion valve and compressor
What sparks can be produced by the combined use of electronic expansion valve and compressor Electronic expansion valve and compressor are indispensable refrigeration accessories in refrigeration equipment and refrigeration equipment, and they are used together with high efficiency.
-
08/02/2020
How to solve the problem of high radiation in the refrigerator
Although the radiation of the refrigerator cannot be said to be large, the radiation protection cannot be ignored. Many people think that although the electric refrigerator has radiation, the radiation is not large, and it should not have an impact on the human body.
-
06/25/2020
Classification of air-conditioning compressors
The air-conditioning compressor plays the role of compressing and driving the refrigerant in the air-conditioning refrigerant circuit. The working circuit is divided into an evaporation area (low pressure area) and a condensation area (high pressure area). The indoor unit and outdoor unit belong to the high-pressure or low-pressure area (depending on the working state), and the compressor is generally installed in the outdoor unit.