03/15/2021
FANUC FANUC spindle drive fault diagnosis
The motor does not rotate or the speed is abnormal After starting the spindle drive system, if the main motor does not rotate or the speed is abnormal, the possible causes are as follows
-
06/14/2020
What about Mitsubishi refrigeration compressors? What types of Mitsubishi refrigeration compressors?
Refrigeration compressor is a very important part of the refrigeration system, and Mitsubishi refrigeration compressor is a very good refrigeration compressor brand on the market, but Mitsubishi refrigeration compressor is not only one type, today Xiaobia 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
08/14/2020
Trouble shooting and correct selection method for thermal expansion valve debugging
As we all know, the thermal expansion valve is one of the four major components in the refrigeration system. It is responsible for reducing the refrigerant from the condensing pressure to the evaporating pressure in the system
-
06/24/2020
What to do if the refrigerator does not cool in winter
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
-
08/12/2020
Causes of noise in circular cooling towers and noise reduction measures
Causes of noise in circular cooling towers and noise reduction measures<br></br> Many people find that the noise is loud after purchasing a circular cooling tower. How do these noises occur? Let’s analyze it for you today.
-
09/10/2020
10 principles of air compressor selection
Air compressor is the basic product of industrial modernization. Air compressor is to provide air source power. It is the main body of electromechanical bleed air source device, which is the core equipment of pneumatic system.
-
06/30/2020
Lubrication method for air conditioner compressor fault maintenance
Lubrication method for air conditioner compressor fault maintenance The specific conditions of the lubrication method for air conditioner compressor fault maintenance are as follows:
-
07/29/2020
Briefly talk about scroll, screw, piston, centrifugal refrigeration compressor Piston refrigeration compressor
Piston refrigeration compressor<br></br> Piston type (ie, reciprocating) refrigeration compressors are widely used, but the displacement is not large. Generally, they are small and medium-sized compressors. The cooling capacity of general air-conditioning conditions is less than 300kW.
-
08/23/2021
Why We Use VFD - Efficiency and Performance
The Variable Frequency Drive (VFD) is a device widely used to convert the constant voltage of an autonomous AC power source into a variable voltage for controlling the torque
-
07/07/2020
The aging of air conditioners caused fires. The heat is coming.
The aging of air conditioners caused fires. The heat is coming. Are your home appliances overaged? The police reminded: As summer is approaching, we should pay attention to the service life, quality and installation environment of household appliances. The wires of many electrical appliances are mainly insulated by a layer of rubber on the outside.