Above Panel Seal (IP): To IP67 (excluding some handle options)
Number of Switches: 2, 4, or 8
Nominal Current: 6A, 10A, or 16A
Maximum Voltage: 250V AC
Contacts #1 6A - V4: Gold
Contacts #2 16A - V3: Silver
Contacts #3 10A - V4: Silver
Contacts #4 Right Angle: Silver
Contacts #5 Faston Style - V4: Silver
Contacts #6 Faston Style - V3: Silver
Contacts #7: Silver
Switch Contacts: Changeover
Contact Life: Load Dependent
Pushbutton Cable: Blue
APEM Switch 2V27F1100
People who bought this item also viewed
Kriwan Switch 3164918
Siemens Switch 3SU1002-2BM10-0AA0
PILZ Switch PSEN sl-0.5p 1.1 1switch
Omron Switch D4B-2A71N
IFM Sensor TM4311
Schneider Circuit Breaker LV429742
Eaton Contactor DILM72C(RDC24)
SHOWA Overload Pump OLP8SB-H-L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
JABSCO Diaphragm Pump 42755-0092
CKD Air Cylinder BHG-05CS-T2H-D
Nidec Fan H35520-58
Recent related posts
-
08/20/2020
Operation method for filling freon in refrigeration system of high and low temperature box
The operation method of filling Freon in the refrigeration system of the high and low temperature box is as follows: 1, prepare a scale, weigh the freon cylinder, and record the net weight of the total weight Leon.
-
09/22/2020
Thyristor solid medium voltage soft starter
I. Overview In our country's coal mine, petroleum, chemical industry, steel, power generation, water supply, cement building materials and other fields, there are a large number of 3KV, 6KV, 10KV and other voltage levels of medium and high voltage AC asynchronous motors. A large part of them do not require speed regulation, but need to solve the starting problem of these high-voltage large motors.
-
07/01/2020
Three major causes of compressor cracks in winter
Three major causes of compressor cracks in winter When using the compressor in winter, we may encounter some problems, such as cracks in the compressor body. There are many ways to cause cracks in the compressor. After summing up, the specifics can be summarized as the following three points:
-
09/04/2020
The difference between ordinary asynchronous motor and variable frequency motor
1. Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which cannot fully meet the requirements of variable frequency speed regulation
-
08/14/2020
Effective means to reduce the resistance of condenser heat transfer system
To ensure that the condenser has a higher heat transfer coefficient, it is necessary to reduce the resistance in the system. There are three ways to achieve this goal.
-
01/12/2021
Recommend that you use Mitsubishi Electric Air Conditioner
Recommend that you use Mitsubishi Electric Air Conditioner Recently, many businesses recommend Mitsubishi Electric air conditioners, Emphasized the keel motor; Let me introduce you today: Where is the keel motor? Mitsubishi Electric patent: [ 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب
-
07/20/2020
Analysis of circuit diagrams of two compressors' phase failure protection
Analysis of circuit diagrams of two compressors' phase failure protection Air compressor phase failure protection circuit Protection circuit diagram Air compressor phase failure protection circuit
-
08/03/2022
Differences Between Overflow Valve and Pressure Relief Valve
Overflow valve is to prevent system overload and ensure safety. The pressure relief valve reduces the system pressure on the premise that the system is not overloaded.
-
03/14/2023
Working Principles and Characteristics of Common Water Pumps
Water pump is a machine that transports or pressurizes liquids, which is mainly composed of impeller, pump case, pump shaft, bearing, filling seal device, and other parts.
-
08/13/2020
Water-cooled chillers need to be cautious when choosing cooling towers
In many special use environments, companies need to apply water-cooled chillers. Because water-cooled chillers need the help of cooling towers during operation, they need to follow the