Panel thickness: 2.5 mm (.098) with 2 nuts - 4 mm (.157) with 1 nut
Low level or mechanical life: 100,000 cycles
Operating temperature: -40°C to +85°C (-40°F to 185°F)
Initial contact resistance: 10 mΩ max.
Insulation resistance: 1,000 MΩ min. at 500VDC
Dielectric strength:
1,000 Vrms 50 Hz min. between terminals
1,500 Vrms 50 Hz min. between poles
1,500 Vrms 50 Hz min. between terminals and frame
Contact bounce: 2 ms max.
Electrical life at full load:
50,000 cycles for single and double pole 40,000 cycles for 3 pole
30,000 cycles for 4 pole
APEM Switch 5658
People who bought this item also viewed
Balluff Switch BES 516-325-G-E4-C-02
Kriwan Switch 3164918
PILZ Switch PSEN sl-0.5p 1.1 1switch
PILZ Switch 570500
Schneider Sensor 9121056000
GE Circuit Breaker EP101UL D10
Schneider Contactor LC1D40004
KOSMEK Overload Pump PH1661-SA
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Switch D3D-131
SLDR Tool for Metal Cutting M42-26.1mm
Recent related posts
-
08/29/2020
Discussion on ways to reduce the design cost of air compressor
Reduce the friction between the end face of the crankshaft and the end face of the crankcase On the direct-coupled air compressor, the front end of the crankshaft adopts gear transmission, and the gears are divided into straight and helical teeth.
-
08/13/2020
Correct operation method and precautions of distribution box during cold storage installation
In the process of cold storage installation, the use of cold storage power distribution boxes is a very important content, but most people are not very familiar with the normal operation of cold storage power distribution boxes.
-
07/19/2020
Have you mastered the general troubleshooting methods for ammonia refrigeration
In the refrigeration system of the cold storage, the refrigeration compressor is the core equipment, usually called the refrigeration host. At present, piston refrigeration compressors are mostly used in small and medium-sized cold storage refrigeration systems. Due to the different refrigerants,
-
07/14/2020
Teach you 10 self-cooling drinks, do it whenever you want
1. First cut the oranges and lemons into small corners, this is not a big deal, just put it in a glass. 2. The orange and lemon corners are accumulated in the glass. There will be juice on one side and fragrance oil in the peel on the other side, so if you squeeze it under the mouth of the cup, the aroma will be much stronger.
-
07/14/2020
How to solve the low-pressure fault during the operation of the chiller?
How to solve the low-pressure fault during the operation of the chiller? The chiller belongs to industrial machinery and equipment.
-
07/01/2020
Three major causes of compressor cracks in winter
Three major causes of compressor cracks in winter When using the compressor in winter, we may encounter some problems, such as cracks in the compressor body. There are many ways to cause cracks in the compressor. After summing up, the specifics can be summarized as the following three points:
-
09/14/2020
Troubleshooting of high pressure air compressor
1-0.27/150 Type High Pressure Air Compressor Troubleshooting Method Fault Features Sound in the crankcase Possible cause a. The screw and nut of the connecting rod are loose. Whether the big-end bearing of the connecting rod is loose.
-
07/14/2020
Compressor 9 types of faults and hazard analysis are all here! ! !
Compressor 9 types of faults and hazard analysis are all here! ! ! 1. Common faults of compressor — start with liquid Starting with fluid is a problem that easily occurs when the machine is stopped. During shutdown, the refrigerant will migrate from the system back to the compressor and deposit in the lubricant.
-
07/18/2020
The safe operation rules of the cold storage Freon refrigeration compressor unit
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
09/05/2020
The pipeline is not working well, and the compressor is exhausted
Many users have invested a lot of energy and money in the selection, operation and maintenance of compressor equipment, but due to negligence on the compressed air pipeline, a lot of waste has been caused.