Global one-stop procurement platform for industrial spare parts.
support01@okmarts.com service@okmarts.com hydraulic@okmarts.com
Okmarts.com Online Store, Refrigeration Compressor Price, O&Kmarts Logo
Max 200 characters
Display the website inEN
EN
translate to EN
EN
translate to ES
ES
translate to العربية
العربية
All
OMRON
OMRON
  • HMI
    HMI
  • Soft Starter
    Soft Starter
  • Transmitter
    Transmitter
  • Power Supply
    Power Supply
  • Level Meter
    Level Meter
  • Relay
    Relay
  • Safety Laser Measure Meter
    Safety Laser Measure Meter
  • Resistor
    Resistor
Yageo
Yageo
  • Resistor
    Resistor
SAWANA
SAWANA
  • Relay
    Relay
  • Resistor
    Resistor
VISHAY
VISHAY
  • Capacitor
    Capacitor
  • Resistor
    Resistor
UniOhm
UniOhm
  • Resistor
    Resistor
TA-I
TA-I
  • Resistor
    Resistor
All Brands
All Brands
    • a
    • b
    • c
    • d
    • e
    • f
    • g
    • h
    • i
    • j
    • k
    • l
    • m
    • n
    • o
    • p
    • q
    • r
    • s
    • t
    • u
    • v
    • w
    • x
    • y
    • z
    • 3
    • 7
      Top Picks
      • Arcol Resistor HS1006R8J
      1/1
      Arcol Resistor HS1006R8J

      There is no price at present, you can Request a Quote

      • Specifications
      • Q&A
      • Reviews
      Tolerance :±5 % Rated power :100 W Resistance: 6.8 Ω

      Ask questions

      (0/1,200)

      Max 1200 characters

      • Q: Is my personal information secure when shopping on your platform?

        A: Absolutely! We take the security and privacy of your personal information seriously. Our platform utilizes advanced encryption and security measures to protect your data, ensuring a safe and secure shopping experience.

      • Q: How can I check the status of my refund?

        A: To check the status of your refund, you can contact our customer service team and provide them with the necessary details, such as your order number and refund request. They will assist you in tracking the progress of your refund.

      • Q: Can I buy products as a guest or do I need to create an account?

        A: We support guest checkout. There are three steps for you to buy products as a guest. First, you should place an order. Then, you can proceed to the checkout process. Last, you should make a payment. If you only purchase as a guest without creating an account, you’ll miss out on the benefits of being a member.

      View More
      Question has been sent successfully

      Reviews

      • A

        Anonymous user

        Nov 25, 2022

        Arcol Resistor HS1006R8J
        All was ok! No problems whatsoever.
        Helpful
        Unhelpful

      Arcol Resistor HS1006R8J

      There is no price at present, you can Request a Quote

      People who bought this item also viewed

      New In stock for sale, Schneider Surge Protection Device PE66DP

      Schneider Surge Protection Device PE66DP

      US$51.18
      New In stock for sale, Ferraz Shawmut Fuse NH2GG69V200

      Ferraz Shawmut Fuse NH2GG69V200

      US$57.69
      New In stock for sale, TYCO Relay KUP93-14D13-24

      TYCO Relay KUP93-14D13-24

      US$158.85

      Customers frequently viewed

      New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

      IWAYA DENKI Water Pump 25CJT0752

      US$2307.69
      New In stock for sale, Panasonic Servo Motor MHMF022L1V2M

      Panasonic Servo Motor MHMF022L1V2M

      US$653.85
      New In stock for sale, Honeywell Solenoid Valve VE4025B1045

      Honeywell Solenoid Valve VE4025B1045

      US$334.62
      New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

      ROTEN Mechanical Seal 8E5K-22-X

      US$384.62
      New In stock for sale, SANDSUN Overload Pump VA08H-760

      SANDSUN Overload Pump VA08H-760

      US$1568.40
      New In stock for sale, GS Battery 6-QW-60(450)-(55D23L-KR)

      GS Battery 6-QW-60(450)-(55D23L-KR)

      US$646.15
      New In stock for sale, Rechi Compressor 44R273A

      Rechi Compressor 44R273A

      US$341.00
      New In stock for sale, Bosch Rexroth Linear Guideway Runner Block R165381920

      Bosch Rexroth Linear Guideway Runner Block R165381920

      US$107.69
      New In stock for sale, MINDMAN Air Cylinder MCQV2-11-40-200

      MINDMAN Air Cylinder MCQV2-11-40-200

      US$88.46
      New In stock for sale, Mitsubishi Compressor YB645WTG

      Mitsubishi Compressor YB645WTG

      US$549.00
      New In stock for sale, Rechner Sensor KAS-80-37-A-D34-PPO-Z02-1-HPCapacitive proximity sensor

      Rechner Sensor KAS-80-37-A-D34-PPO-Z02-1-HPCapacitive proximity sensor

      US$57.69
      New In stock for sale, Yaskawa Servo Drive SGDD-50BF8A-P

      Yaskawa Servo Drive SGDD-50BF8A-P

      Contact Us
      New In stock for sale, Inovance Servo Motor ISMH2-25C30CB-R221X

      Inovance Servo Motor ISMH2-25C30CB-R221X

      Contact Us
      New In stock for sale, IXYS Rectifier Module MDD95-22N1B

      IXYS Rectifier Module MDD95-22N1B

      US$33.85
      New In stock for sale, SKF Bearing NU 305 ECP

      SKF Bearing NU 305 ECP

      US$71.15
      New In stock for sale, Danfoss Compressor SM112A3VS

      Danfoss Compressor SM112A3VS

      Contact Us
      New In stock for sale, Toshiba Frequency Converter VFD VFS11-4037PM-WP

      Toshiba Frequency Converter VFD VFS11-4037PM-WP

      Contact Us
      New In stock for sale, GATES Belt K060755

      GATES Belt K060755

      Contact Us
      New In stock for sale, Delta Fan AFB03524H-R00

      Delta Fan AFB03524H-R00

      Contact Us
      New In stock for sale, Baumer Encoder ITD2PH00.2 1024 P NI S21SG8 E 14 IP65

      Baumer Encoder ITD2PH00.2 1024 P NI S21SG8 E 14 IP65

      US$1687.50

      Recent related posts

      Thyristor solid medium voltage soft starter

      09/22/2020

      Thyristor solid medium voltage soft starter

      I. Overview In our country's coal mine, petroleum, chemical industry, steel, power generation, water supply, cement building materials and other fields, there are a large number of 3KV, 6KV, 10KV and other voltage levels of medium and high voltage AC asynchronous motors. A large part of them do not require speed regulation, but need to solve the starting problem of these high-voltage large motors.

      Cold storage installation and cold storage installation selection

      07/17/2020

      Cold storage installation and cold storage installation selection

      First, the cold storage installation should pay attention to the following: the type of cold storage 1, according to temperature: A, high temperature cold storage (plus or minus 5 degrees Celsius): suitable for fruit and vegetable preservation; B, medium temperature cold storage (minus 10 degrees-minus 5 degrees):

      A newly installed air conditioner trips as soon as it is plugged in. What's the matter

      07/30/2020

      A newly installed air conditioner trips as soon as it is plugged in. What's the matter

      This question is about the first use of newly purchased appliances. This question actually asked two questions: One is that the newly installed air conditioner trips as soon as it is plugged in. Why? Second, why does it stop tripping after removing the neutral wire? The Electrician's Home will answer this question from these two aspects.

      Computer Room Air Conditioning: Work Principle, Characteristics and Technical Requirements, Benefits

      01/26/2024

      Computer Room Air Conditioning: Work Principle, Characteristics and Technical Requirements, Benefits

      Computer room air conditioners (CRACs), to put it simply, are air conditioners dedicated to computer rooms.

      PLC Analog Input

      05/19/2022

      PLC Analog Input

      PLC analog inputs usually use voltage signals in the range of 20 volts and current signals in mA. Each PLC manufacturer has I / O modules to process these types of signals

      What are the causes of air conditioning trip

      06/20/2020

      What are the causes of air conditioning trip

      What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

      What is a Variable Valve Timing Solenoid?

      01/16/2023

      What is a Variable Valve Timing Solenoid?

      The variable valve timing (VVT) solenoid is a component of the variable valve timing system. It adjusts oil flow based on engine speed and load.

      Why is My AC Not Cooling? (Detailed Reasons and Solutions)

      05/22/2023

      Why is My AC Not Cooling? (Detailed Reasons and Solutions)

      The air conditioner is a household appliance that we mostly use in the summer, and occasionally we encounter the problem of the air conditioner not cooling.

      The experience of building a small cold storage correctly, come and learn!

      08/16/2020

      The experience of building a small cold storage correctly, come and learn!

      Relying on a series of advantages such as short installation period, fast and efficient use, and reasonable price, the construction of small cold storage has quickly been recognized by the market and has been widely used in many industries.

      Why Electromagnetic Flowmeter Needs Grounding?

      04/18/2022

      Why Electromagnetic Flowmeter Needs Grounding?

      Before discussing grounding, I want to give you a question: what is grounding? We usually talk about all kinds of grounding including protection grounding, shielding grounding, working grounding, signal grounding and so on.

      • Welcome to O&Kmarts

        Is there anything we can help?

        Email us
      • Feedback

      Join in

      Join in to enjoy exclusive discounts and give you greater discounts

      See More About O&Kmarts Member
      Sign up now

      Common Problem

      Payment Methods
      Shipping Guide
      Sales and Refund Policy
      FAQs

      About O&Kmarts

      About Us
      Membership

      Website Terms

      Privacy Policy
      Terms Of Use
      Bidding Agreement
      Review Rules

      Customer Service

      support01@okmarts.com
      service@okmarts.com
      hydraulic@okmarts.com
      +86-28-84166335
      GMT+08:00 Mon-Fri, 9:00 AM-7:00 PM
      Customer Feedback

      POPULAR PRODUCTS :

      HVR SR2825 680L 25CJT0752 MHMF022L1V2M VE4025B1045 8E5K-22-X VA08H-760 2904602 Bifold FP10P-S1-08-32-NU-V-77A-24D-ML-30-K85 CKD 4F310-10-L-DC24V CKD 4GB249-E2 Copeland CRA1-0150-TFC-270 Copeland CS20K6E-PFZ-255 Copeland DLFE-301-EWK Danfoss 018Z7363 dr 120 24 Goetze 851SGK kde2406ptb1 LG GKS141CMA MAC 250B-611JJ MAC PPC5C-ABA-AGAB-BBD-JB maneurop mt22jc4ave psd1212pmbx rsp 1500 24 Sanyo Denki ST1-109-642-30 Togami PAK-20J31 UNIVER AE-1000

      Disclaimer: All brand names, model or type numbers or marks listed on the website are owned by their respective manufacturers. These terms are used for identification purposes only and are not intended to indicate affiliation with OEM companies. Product pictures shown on the website are for illustrative purposes only and the actual item may vary in design, specification, etc. Confirm at the time of purchase if you are unsure.

      © eCommerce. 2017-2026. All Rights Reserved
      © eCommerce. 2017-2026. All Rights Reserved
      Press and drag the mouse to start taking a screenshot