Supply Voltage - Min: 1.8V
Supply Voltage – Max: 5.5V
Minimum operating temperature:-40 C
Maximum operating temperature:85 C
ATMEL IC Integrated Circuit Chip ATTINY1634-MU
People who bought this item also viewed
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Protechnic Fan MGA12012LR-A25
SKF Oil Seal 60X75X8 HMSA10 V(FKM)
IFM Sensor OGE304
AirTAC Air Cylinder MARU16X300S
Ebmpapst Fan D2E146-CD51-23
Recent related posts
-
07/11/2022
How to Replace Mechanical Seals in Centrifugal Pumps
Mechanical seals are used in centrifugal pumps to keep water or any liquid from making contact with the delicate parts of the machine.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/16/2020
Common failures and maintenance of overload protectors for air-conditioning compressors
Overload protector of air conditioner compressor Installed between the active and passive sides of the power transmission, when an overload fault occurs (torque exceeds the set value), the torque limiter will separate, thereby effectively protecting the driving machinery and the load. Just like its name, the fundamental function of the overload protector is to protect the air-conditioning compressor.
-
08/09/2020
The harm of overheating of industrial water chiller to equipment during use
The overheating problem of industrial chillers has a serious negative impact on the efficiency of the equipment. In order to maintain the safety and stability of industrial chillers, when using industrial chillers,
-
08/11/2020
Types of refrigerants and leak detection methods
Refrigerants are also called refrigeration working fluids, commonly known as refrigerants in some areas in the south. It is a working substance that continuously circulates in the refrigeration system and realizes refrigeration through its own state changes.
-
06/14/2020
How to properly maintain the refrigeration compressor
How to properly maintain the refrigeration compressor 1. Frequently check whether there are debris or even conductive objects in the motor, whether the coil is damaged, and whether the stator and rotor are rubbed, otherwise the motor will burn out after ﰸ2 䀀 ᅵ皥
-
08/08/2020
How to deal with the burnout of the air conditioner compressor pile head, novices should use it with caution
The compressor is an important part of the air-conditioning equipment. Due to its large current, the temperature is sometimes low and sometimes high, which easily causes moisture adsorption.
-
12/10/2021
Top 10 Brands of HMI Worldwide
HMI is the abbreviation of human machine interface, which is also known as user interface. It is the medium of interaction and information exchange between the system and users.
-
09/15/2020
Matching selection for small internal compression process design
As a traditional process type, small internal compression process equipment has been produced in the okmarts.com factory for many years. It is well received by users for its inherent advantages.
-
12/01/2022
The Constitution of a Linear Guideway
The linear guideway, also called the linear guide, is used for high-precision or high-speed linear reciprocating motion.