Global one-stop procurement platform for industrial spare parts.
support01@okmarts.com service@okmarts.com hydraulic@okmarts.com
Okmarts.com Online Store, Refrigeration Compressor Price, O&Kmarts Logo
Max 200 characters
Display the website inEN
EN
translate to EN
EN
translate to ES
ES
translate to العربية
العربية
All
Autonics
Autonics
  • HMI
    HMI
  • Encoder
    Encoder
  • Sensor
    Sensor
  • Electric Motor
    Electric Motor
  • Optical Fiber Amplifier
    Optical Fiber Amplifier
  • Temperature Controller
    Temperature Controller
  • Digital Display Controller
    Digital Display Controller
  • Relay
    Relay
  • Switch
    Switch
Omron
Omron
  • Encoder
    Encoder
  • Light Curtain
    Light Curtain
  • VFD
    VFD
  • Sensor
    Sensor
  • PLC
    PLC
  • Transformer
    Transformer
  • Optical Fiber Amplifier
    Optical Fiber Amplifier
  • Fan
    Fan
  • Digital Display Controller
    Digital Display Controller
  • Module
    Module
  • Battery
    Battery
  • Switch
    Switch
Wide Plus
Wide Plus
  • Digital Display Controller
    Digital Display Controller
Bongshin
Bongshin
  • Digital Display Controller
    Digital Display Controller
Ewelly
Ewelly
  • Digital Display Controller
    Digital Display Controller
Fotek
Fotek
  • Temperature Controller
    Temperature Controller
  • Digital Display Controller
    Digital Display Controller
All Brands
All Brands
    • a
    • b
    • c
    • d
    • e
    • f
    • g
    • h
    • i
    • j
    • k
    • l
    • m
    • n
    • o
    • p
    • q
    • r
    • s
    • t
    • u
    • v
    • w
    • x
    • y
    • z
    • 3
    • 7
      Top Picks
      • Autonics Digital Display Controller DPU34B-080N
      1/1
      Autonics Digital Display Controller DPU34B-080N

      There is no price at present, you can Request a Quote

      • Specifications
      • Q&A
      • Reviews
      Supported communication output model: RS485 (Modbus RTU) Control inputs: analog (current, voltage), ON/OFF(voltage pulse, no voltage), communication (RS485), potentiometer DI input: auto/manual switch, run/stop switch, reset, output hold, SP specified (6 setting points can be customized) Alarm output: over current, over voltage, fuse breakage, radiator overheating, equipment failure, heater disconnection alarm (part of heater disconnection detection)

      Ask questions

      (0/1,200)

      Max 1200 characters

      • Q: How can I write a review for a purchased product?

        A: After completing the order, you can go to the order page and select the items you want to review from the product list. You can share your shopping experience, and feedback on product quality and service to help other buyers make better decisions.

      • Q: What should I do if I receive a damaged or defective item?

        A: If you receive a damaged or defective item, please contact our customer service team immediately. Provide them with the necessary details and, if possible, include photos of the damage. We will assist you in resolving the issue by offering a replacement, refund, or suitable solution.

      • Q: How can I view the size and specifications of a product?

        A: On the product details page, you can find detailed information about size and specifications, including size charts, specific measurements, and more, to help you select the right product.

      View More
      Question has been sent successfully

      Reviews

      • A

        Anonymous user

        Nov 25, 2022

        Autonics Digital Display Controller DPU34B-080N
        All was ok! No problems whatsoever.
        Helpful
        Unhelpful

      Autonics Digital Display Controller DPU34B-080N

      There is no price at present, you can Request a Quote

      Customers frequently viewed

      New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

      IWAYA DENKI Water Pump 25CJT0752

      US$2307.69
      New In stock for sale, Panasonic Servo Motor MHMF022L1V2M

      Panasonic Servo Motor MHMF022L1V2M

      US$653.85
      New In stock for sale, Honeywell Solenoid Valve VE4025B1045

      Honeywell Solenoid Valve VE4025B1045

      US$334.62
      New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

      ROTEN Mechanical Seal 8E5K-22-X

      US$384.62
      New In stock for sale, SANDSUN Overload Pump VA08H-760

      SANDSUN Overload Pump VA08H-760

      US$1568.40
      New In stock for sale, GS Battery 6-QW-60(450)-(55D23L-KR)

      GS Battery 6-QW-60(450)-(55D23L-KR)

      US$646.15
      New In stock for sale, Rechi Compressor 44R273A

      Rechi Compressor 44R273A

      US$341.00
      New In stock for sale, Bosch Rexroth Linear Guideway Runner Block R165381920

      Bosch Rexroth Linear Guideway Runner Block R165381920

      US$107.69
      New In stock for sale, MINDMAN Air Cylinder MCQV2-11-40-200

      MINDMAN Air Cylinder MCQV2-11-40-200

      US$88.46
      New In stock for sale, Mitsubishi Compressor YB645WTG

      Mitsubishi Compressor YB645WTG

      US$549.00
      New In stock for sale, CHANTO Air Cylinder ACM25X175

      CHANTO Air Cylinder ACM25X175

      US$23.88
      New In stock for sale, NSK Bearing HR 32219 J

      NSK Bearing HR 32219 J

      US$212.31
      New In stock for sale, Amgis Transformer L01-6320

      Amgis Transformer L01-6320

      US$76.92
      New In stock for sale, Texas Instruments TI IC Integrated Circuit CSD95372BQ5MT

      Texas Instruments TI IC Integrated Circuit CSD95372BQ5MT

      US$27.10
      New In stock for sale, KCL Vane Pump DVQ20-32-F-RAA-03

      KCL Vane Pump DVQ20-32-F-RAA-03

      US$711.54
      New In stock for sale, HONGFA Relay HFE15-1-48-1ZT-L2

      HONGFA Relay HFE15-1-48-1ZT-L2

      US$5.77
      New In stock for sale, Banner Sensor T30UIPBQ

      Banner Sensor T30UIPBQ

      US$711.55
      New In stock for sale, VBI Bearing 7311DFP5

      VBI Bearing 7311DFP5

      US$129.62
      New In stock for sale, Fuji Circuit Breaker BC63E1CG-2P025

      Fuji Circuit Breaker BC63E1CG-2P025

      US$42.69
      New In stock for sale, CHINT Switch CJ20-250

      CHINT Switch CJ20-250

      US$337.69

      Recent related posts

      High pressure failure of chiller and its treatment measures

      08/07/2020

      High pressure failure of chiller and its treatment measures

      High pressure failure of chiller and its treatment measures<br></br> Recently, many micro friends asked the editor about the causes of the high-pressure failure of the chiller. The editor recently reviewed information and sorted out some relevant measuresŒﰨ2䀀湠疌VǜV㠠ư㠠ư㠠ư類

      The adjustment principle of the screw compressor slide valve is actually very simple!

      07/22/2020

      The adjustment principle of the screw compressor slide valve is actually very simple!

      Today, I will tell you about the maintenance example of the poor cooling effect of the air conditioner.<br></br> <br></br> 1. The cooling is poor, and the operating frequency is not up to the highest. The exhaust pipe overheating code will be displayed for about 20 minutes.<br></br>

      Key points for safe operation of large-scale cold storage refrigeration operators

      08/21/2020

      Key points for safe operation of large-scale cold storage refrigeration operators

      The main points of safe operation are as follows:   1, safe operation regulations    Generally, there should be safety operating procedures for the machines and equipment of refrigeration installations, and refrigeration operators must strictly follow them to ensure safe production.

      R32 refrigerant training

      07/29/2020

      R32 refrigerant training

      Note: For products using R290 (such as dehumidifiers), if system failures are involved, automatic welding torch repairs are strictly prohibited. Please return the products to the factory according to the process.

      Precautions for cold storage installation

      08/24/2020

      Precautions for cold storage installation

      Library refers to the use of artificial means to create an environment different from outdoor temperature or humidity. Pay attention to the following points when installing cold storage:

      What are the causes of air conditioning trip

      06/20/2020

      What are the causes of air conditioning trip

      What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

      Building & Construction Hold Over 20 % Share in Portable Air Compressor Market 2019 to 2027

      07/03/2020

      Building & Construction Hold Over 20 % Share in Portable Air Compressor Market 2019 to 2027

      LOS ANGELES, United States: QY Research published latest market research report on global Mute Oil Free Air Compressor market 2020 with industry detail study, growth analysis, latest and future trends, leading companies analysis, regional analysis and forecast by 2026.

      Characteristics and trends of assembled centrifugal compressors

      09/22/2020

      Characteristics and trends of assembled centrifugal compressors

      I. Introduction    Assembled centrifugal compressor is also called assembling integral gear speed-increasing centrifugal compressor, and it has developed rapidly in the world in recent years.

      Hitachi water source heat pump compressor

      07/05/2020

      Hitachi water source heat pump compressor

      How does the air conditioning compressor work? The air-conditioning compressor is also called a rotary (rotor) compressor, and its working principle is to rely on an eccentric rotor under the action of spring force, the compressor, and the eccentric rotor are always in contact with the container separated by the sliding container Changes to achieve a process of compression. When the eccentric rotor rotates, the volume of the container changes and the gas is compressed.

      Will the effect of villa ground source heat pump be worse after years of use

      08/19/2020

      Will the effect of villa ground source heat pump be worse after years of use

      In recent years, ground source heat pumps have become a must for villa decoration. Of course, there are also customers who are concerned about whether the effect of ground source heat pumps will deteriorate after years of use. okmarts.com

      • Welcome to O&Kmarts

        Is there anything we can help?

        Email us
      • Feedback

      Join in

      Join in to enjoy exclusive discounts and give you greater discounts

      See More About O&Kmarts Member
      Sign up now

      Common Problem

      Payment Methods
      Shipping Guide
      Sales and Refund Policy
      FAQs

      About O&Kmarts

      About Us
      Membership

      Website Terms

      Privacy Policy
      Terms Of Use
      Bidding Agreement
      Review Rules

      Customer Service

      support01@okmarts.com
      service@okmarts.com
      hydraulic@okmarts.com
      +86-28-84166335
      GMT+08:00 Mon-Fri, 9:00 AM-7:00 PM
      Customer Feedback

      POPULAR PRODUCTS :

      Omron Digital Display Controller Wide Plus Digital Display Controller Autonics Digital Display Controller 25CJT0752 MHMF022L1V2M VE4025B1045 8E5K-22-X VA08H-760 ad0912hb a70gl ad1212hb a76gl ANB33FCLMT ava5538exn caj4461y Commonwealth FP-108EX-S1-B h23a423abka hcm094t4lc6 hlg 240h 12 JH514YBC kd1204pks2 MCSCP024DG000010 Nidec R40W12BS4D8-07A581 RE231VHAMC Rechi 39F113C SUNON GB1207PGV1-A T12E48BS1M7 07 Tecumseh AWA5524EXC Toshiba PZ90H1C TS36VGBC

      Disclaimer: All brand names, model or type numbers or marks listed on the website are owned by their respective manufacturers. These terms are used for identification purposes only and are not intended to indicate affiliation with OEM companies. Product pictures shown on the website are for illustrative purposes only and the actual item may vary in design, specification, etc. Confirm at the time of purchase if you are unsure.

      © eCommerce. 2017-2025. All Rights Reserved
      © eCommerce. 2017-2025. All Rights Reserved
      Press and drag the mouse to start taking a screenshot