There is no price at present, you can Request a Quote
Voltage: 110V AC 50Hz
Operation Pressure: 0.15-1.0MPa
Ambient Temperature: 5Degs -50Degs
Lubrication: ISO VG 32 turbine oil, or equivalent oil is recommended.
Manual Operation: Manual push button / Non-lock type
Insulation Grade: Class B
azbil TACO YAMATAKE Solenoid Valve 363-401-10B2
There is no price at present, you can Request a Quote
People who bought this item also viewed
Daikin Solenoid Valve LS-G02-2DA-20-EN
Festo Solenoid Valve MN2H-5/2-D-01-FR
CHELIC Solenoid Valve SV-6102-W
Honeywell Solenoid Valve VE4025C1002
Danfoss Compressor HRH031T9LP6
Contrinex Sensor DW-DD-615-M12-120
Danfoss Expansion Valve 067N4015
Eaton Vickers Solenoid Coil 02-101725
KOMPASS Check Valve MBB-02-H
Jeou Gang Overflow Valve MRV-03-P-2-W
PALL Filter UE310AT13H
Danfoss Sight Glass SGP12SN
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Nidec Fan M34709-33
Festo Solenoid Valve JMEBH-5/2-1/8-S-B
ABB Circuit Breaker 2CDS251001R0428
MINDMAN Air Cylinder MCMJP-18-16-5M
JSCC Speed Reducer 70GK300H
Recent related posts
-
08/11/2020
8 main points of HVAC field construction experience
1. Equipment installation<br></br> 1. The installation location of the air-conditioning host should be convenient for inspection and repair, and should not affect its use function, especially pay attention to heat dissipation.
-
08/15/2020
Solution to the condensing pressure of the chiller refrigeration system
1. The condenser of the chiller is dirty Computer room chillers generally use air-cooled condensers, which are composed of multiple sets of coils, and fins are added to the coils to increase the heat transfer area on the air side.
-
09/18/2021
Analysis of Refrigerant Prices Rising
Refrigerant is a compound that usually exists in a liquid or gaseous state. It easily absorbs heat from the environment
-
08/23/2020
Teach you ten major inspection standards to see the pros and cons of air conditioners
The hot summer is approaching the peak season for air-conditioning sales and the peak period for consumers to purchase air-conditioners. Many small partners are often at a loss when faced with the variety of products on the market.
-
09/08/2023
How Does an Air Source Heat Pump Work in Winter? A Comprehensive Guide
In winter, the need for an efficient and reliable heating system is paramount. Among the various options available, air source heat pumps have gained popularity due to their energy efficiency and versatility.
-
07/06/2020
Single Screw Compressor Market Trends, Opportunities, Drivers, Challenges And Porter’s Five Forces Analysis 2020-2026| Bosch, Sanyo (Panasonic), Atlas Copco AB, Ingersoll-Rand PLC, GE Oil & Gas, Gardner Denver, Inc.
LOS ANGELES, United States: QY Research offers an encyclopedic study of the global Single Screw Compressor market with holistic insights into vital factors and aspects that impact future market growth. The global Single Screw Compressor market has been analyzed for the forecast period 2020-2026 and historical period 2015-2020.
-
04/19/2023
Diagnosis and Troubleshooting of Refrigeration Compressor Failure
The main content of the following is the failure diagnosis and troubleshooting related to the refrigeration compressor system. After reading the following content, you will know how to diagnose a refrigeration compressor failure.
-
06/13/2020
Common terms of screw air compressor
Common terms of screw air compressor
-
06/13/2020
Don't be afraid if the refrigeration system is clogged. Here are retrieval and cleaning methods
Don't be afraid if the refrigeration system is clogged. Here are retrieval and cleaning methods Typical features of clogging 1. The refrigerator or air conditioner does not cool for a long time. 2. The suction pressure drops, and even a vacuum stat ﰸ2 䀀 ᅵ皥 䖒皦
-
06/18/2020
Analysis of the circuit diagram of the two compressors' phase failure protection
Analysis of the circuit diagram of the two compressors' phase failure <br><br> Air compressor phase failure <br><br> circuit In the figure, KP is the electrical contact pressure gauge Ai is the CD4073 AND gate circuit, Az is the ~D4025 NOR gate circuit, and A3 is the CD4071 OR gate circuit. The 7806 three-terminal fixed integrated voltage regulator is used as the control circuit for the DC working power supply. When the AC power fails, the relay KA is released and the motor stops. Circuit diagram of compressor phase failure <br><br><img src="{{media url="wysiwyg/Analysis_of_the_circuit_diagram_of_the_two_compressors_phase_failure_protection.jpg"}}" alt="" />