(BES00WN) INDUCTIVE SENSOR
18 times 42.5 MM
CABLE
NORMALLY OPEN (NO)
RATED OPERATING DISTANCE SN is equal to 8 MM
NON-FLUSH
Balluff Sensor BES00WN
People who bought this item also viewed
Balluff Sensor BES00PM
Keyence Sensor OP-87359
Omron Sensor NX1P2-9024DT
Contrinex Sensor BD10-S3-M30-5M
TAKEX Sensor DS-4CRS
Rosemount Transmitter 3051CD4A22A1AB4M5I5
Siemens Flame Detector QRA4.U
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Caddock Resistor MP850-5.00-1%
Recent related posts
-
09/05/2020
The pipeline is not working well, and the compressor is exhausted
Many users have invested a lot of energy and money in the selection, operation and maintenance of compressor equipment, but due to negligence on the compressed air pipeline, a lot of waste has been caused.
-
07/01/2020
The stability of the typical performance of Taikang compressor
The stability of the typical performance of Taikang compressor Many people know the performance of Taikang compressors, but nothing more than the typical characteristics, such as pressure ratio, efficiency, mass flow and additional energy. But many people do not know that Taikang compressor has another more important feature, that is stability. Why is the stability of Taikang compressor so important?
-
06/01/2023
How to Check AC Compressor: A Comprehensive Guide
The air conditioner compressor, also known as the AC compressor, is an essential component of your home's HVAC system.
-
06/14/2020
Cold storage equipment installation and commissioning
Installation of refrigeration compressor unit in cold storage: The condensing unit should avoid installing in high temperature environment, and the outdoor awning should be installed to avoid rain or direct sunlight. The air inlet side of the air-cooled c 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬
-
09/06/2022
How to Select Overflow Valve
The nominal pressure of the overflow valve is determined by the operating pressure, the service temperature range of the safety valve is determined by the operating temperature
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/17/2020
Choose refrigerating oil and start from scratch
Recently, the weather is hot and air-conditioning sales are in the peak season, which has to be reminiscent of "refrigeration". We know that there are many parts that make up refrigeration equipment, and refrigerating oil is an indispensable component.
-
06/24/2020
What's wrong with the freezer not cooling
There are four main reasons: the first is the lack of refrigerant and the compressor has problems; the second is the problem of the power cord of the freezer; the third is the frost in the evaporator of the freezer; the fourth is that the storage in the freezer is too full. Of course, no matter what the reason is, you should find a professional to help repair the loophole or add refrigerant.
-
08/13/2020
Four types of safety protection measures for refrigeration compressors
As the most important component of the chiller, the motor for the refrigeration compressor plays an important role in the after-sales maintenance of the chiller. Moreover, the maintenance cost of the chiller compressor is relatively high.
-
03/13/2021
Working mode of servo driver
The working modes of servo driver are: open loop mode, voltage mode, current mode (torque mode), IR compensation mode, Hall speed mode, encoder speed mode, tachometer mode, and analog position loop mode (ANP mode). (not all of the above modes exist in all models of drives)