Global one-stop procurement platform for industrial spare parts.
support01@okmarts.com service@okmarts.com hydraulic@okmarts.com
Okmarts.com Online Store, Refrigeration Compressor Price, O&Kmarts Logo
Max 200 characters
Display the website inEN
EN
translate to EN
EN
translate to ES
ES
translate to العربية
العربية
All
Nemicon
Nemicon
  • Encoder
    Encoder
Renishaw
Renishaw
  • Encoder
    Encoder
MTL
MTL
  • Encoder
    Encoder
SUMTAK
SUMTAK
  • Encoder
    Encoder
LS Mecapion
LS Mecapion
  • Encoder
    Encoder
HENGSTLER
HENGSTLER
  • Encoder
    Encoder
All Brands
All Brands
    • a
    • b
    • c
    • d
    • e
    • f
    • g
    • h
    • i
    • j
    • k
    • l
    • m
    • n
    • o
    • p
    • q
    • r
    • s
    • t
    • u
    • v
    • w
    • x
    • y
    • z
    • 3
    • 7
      Top Picks
      • Baumer Encoder GM401.Z21
      1/1
      Baumer Encoder GM401.Z21
      $ 1,071 .43

      ✔ In Stock (Can ship in 5-7 days)

      Quantity
      MOQ : 1
      Payment Methods
      T/T pay VISA pay mastercard pay Diners Club pay Discover pay JCB pay American Express pay Stripe pay PayPal pay Google pay Apple pay Link pay venmo pay
      • Online Support 24/7

      • 12 Months Warranty for New Products

      • 30 Days Money Back Guarantee

      • Specifications
      • Q&A
      • Reviews
      Technical data - electrical ratings Voltage supply 10...30 VDC 5 VDC ±10 % Reverse polarity protection Yes (10..30 VDC) / No (5 VDC) Consumption w/o load ≤50 mA (24 VDC) ≤80 mA (5 VDC) Initializing time typ. 20 ms after power on Interface SSI Incremental A 90° B (optional) Function Multiturn Steps per revolution ≤16384 / 14 bit Number of revolutions ≤65536 / 16 bit Absolute accuracy ±0.025 ° Sensing method Optical Code Gray or binary Code sequence CW/CCW coded by connection Inputs SSI clock Control signals UP/DOWN inv. and zero Output stages SSI data: Linedriver RS422 Diagnostic outputs push-pull Incremental output 512, 1024, 2048 pulses + inverted Interference immunity EN 61000-6-2 Emitted interference EN 61000-6-4 Diagnostic function Self-diagnosis Multiturn sensing Approval UL approval / E63076 Technical data - mechanical design Size (flange) ø58 mm Shaft type ø6 mm solid shaft Flange Synchro flange Protection EN 60529 IP 54 (without shaft seal) IP 65 (with shaft seal) Operating speed ≤10000 rpm (mechanical) ≤6000 rpm (electric) Starting acceleration ≤1000 U/s² Starting torque ≤0.015 Nm (+25 °C, IP 54) ≤0.03 Nm (+25 °C, IP 65) Rotor moment of inertia 20 gcm² Admitted shaft load ≤20 N axial ≤40 N radial Material Housing: aluminium Flange: aluminium Operating temperature -25...+85 °C -40...+85 °C (optional) Relative humidity 95 % non-condensing Resistance EN 60068-2-6 Vibration ±0.75 mm - 10-58 Hz, 10 g - 58-2000 Hz EN 60068-2-27 Shock 200 g, 6 ms Weight approx. 400 g Connection Connector M23, 12-pin Connector M12, 8-pin Cable 1 m

      Ask questions

      (0/1,200)

      Max 1200 characters

      • Q: Do I need to pay for shipping when returning a product?

        A: According to our return policy, if the return is due to product quality issues or our mistake, we will cover the return shipping fee. If it's for other reasons, the return shipping fee may be borne by you. Please refer to our return policy for specific details.

      • Q: How can I search for products from specific brands or sellers?

        A: You can enter the brand or merchant name in the search box, and the system will display relevant products, making it convenient for you to quickly find the items you are interested in.

      • Q: How can I apply for a purchase invoice?

        A: On the checkout page, you can select the option for an invoice and fill in the relevant invoice information. We will provide you with the corresponding invoice according to your request.

      View More
      Question has been sent successfully

      Reviews

      • A

        Anonymous user

        Nov 25, 2022

        Baumer Encoder GM401.Z21
        All was ok! No problems whatsoever.
        Helpful
        Unhelpful

      Baumer Encoder GM401.Z21

      $ 1,071 .43
      Click here to view shipping costs.

      ✔ In Stock (Can ship in 5-7 days)

      Quantity
      MOQ : 1
      Payment Methods
      T/T pay VISA pay mastercard pay Diners Club pay Discover pay JCB pay American Express pay Stripe pay PayPal pay Google pay Apple pay Link pay venmo pay
      • Online Support 24/7

      • 12 Months Warranty for New Products

      • 30 Days Money Back Guarantee

      People who bought this item also viewed

      New In stock for sale, SUMTAK Encoder IRT320-2000-002

      SUMTAK Encoder IRT320-2000-002

      US$769.23
      New In stock for sale, SUMTAK Encoder IRS320-1024-001

      SUMTAK Encoder IRS320-1024-001

      US$332.15
      New In stock for sale, Baumer Encoder GXMMW.Z41

      Baumer Encoder GXMMW.Z41

      US$1071.43
      New In stock for sale, Baumer Encoder ITD 01 B14 300T BX KR1 S 4

      Baumer Encoder ITD 01 B14 300T BX KR1 S 4

      US$1071.43
      New In stock for sale, Baumer Encoder GM400.Z33

      Baumer Encoder GM400.Z33

      US$1071.43
      New In stock for sale, Baumer Encoder BMMH 58S1G05C14/405897

      Baumer Encoder BMMH 58S1G05C14/405897

      US$1071.43
      New In stock for sale, Autonics Rotary Encoder E40HB8-40-4-T-24

      Autonics Rotary Encoder E40HB8-40-4-T-24

      US$1153.85
      New In stock for sale, Autonics Rotary Encoder E40HB6-1024-2-N-24

      Autonics Rotary Encoder E40HB6-1024-2-N-24

      US$1153.85
      New In stock for sale, HONTKO Encoder HTR-HB-6.35-100A-H

      HONTKO Encoder HTR-HB-6.35-100A-H

      US$230.77
      New In stock for sale, Autonics Rotary Encoder E40HB6-25-6-V-24

      Autonics Rotary Encoder E40HB6-25-6-V-24

      US$1153.85
      New In stock for sale, Faunc Servo Motor A06B-0227-B200

      Faunc Servo Motor A06B-0227-B200

      US$5192.31
      New In stock for sale, Yaskawa Servo Drive SGDJ-01AS

      Yaskawa Servo Drive SGDJ-01AS

      US$426.92

      Customers frequently viewed

      New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

      IWAYA DENKI Water Pump 25CJT0752

      US$2307.69
      New In stock for sale, Panasonic Servo Motor MHMF022L1V2M

      Panasonic Servo Motor MHMF022L1V2M

      US$653.85
      New In stock for sale, Honeywell Solenoid Valve VE4025B1045

      Honeywell Solenoid Valve VE4025B1045

      US$334.62
      New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

      ROTEN Mechanical Seal 8E5K-22-X

      US$384.62
      New In stock for sale, SANDSUN Overload Pump VA08H-760

      SANDSUN Overload Pump VA08H-760

      US$1568.40
      New In stock for sale, GS Battery 6-QW-60(450)-(55D23L-KR)

      GS Battery 6-QW-60(450)-(55D23L-KR)

      US$646.15
      New In stock for sale, Rechi Compressor 44R273A

      Rechi Compressor 44R273A

      US$341.00
      New In stock for sale, Bosch Rexroth Linear Guideway Runner Block R165381920

      Bosch Rexroth Linear Guideway Runner Block R165381920

      US$107.69
      New In stock for sale, MINDMAN Air Cylinder MCQV2-11-40-200

      MINDMAN Air Cylinder MCQV2-11-40-200

      US$88.46
      New In stock for sale, Mitsubishi Compressor YB645WTG

      Mitsubishi Compressor YB645WTG

      US$549.00
      New In stock for sale, GSWC Bearing 6305-HT2X

      GSWC Bearing 6305-HT2X

      Contact Us
      New In stock for sale, Autonics Rotary Encoder E40HB6-5-2-V-24

      Autonics Rotary Encoder E40HB6-5-2-V-24

      US$1153.85
      New In stock for sale, CKD Solenoid Valve 4F420-08-AC220V

      CKD Solenoid Valve 4F420-08-AC220V

      US$250.00
      New In stock for sale, Kelon Air Conditioner KFR-35GW-QTFDBp-A1(1P26)

      Kelon Air Conditioner KFR-35GW-QTFDBp-A1(1P26)

      US$1307.31
      New In stock for sale, TIMKEN Bearing 32021 3 A HA

      TIMKEN Bearing 32021 3 A HA

      US$100.77
      New In stock for sale, NXP IC Integrated Circuit LPC4330FBD144,551

      NXP IC Integrated Circuit LPC4330FBD144,551

      US$127.45
      New In stock for sale, Copeland Compressor RST55C1E-IAA-199

      Copeland Compressor RST55C1E-IAA-199

      Contact Us
      New In stock for sale, Autonics Rotary Encoder E30S4-1000-3-N-24

      Autonics Rotary Encoder E30S4-1000-3-N-24

      US$150.65
      New In stock for sale, P+F Pepperl Fuchs Sensor ML100-8-1000-RT/102/115

      P+F Pepperl Fuchs Sensor ML100-8-1000-RT/102/115

      US$173.08
      New In stock for sale, Yaskawa Servo Drive SGDJ-A5BNY2

      Yaskawa Servo Drive SGDJ-A5BNY2

      US$634.62

      Recent related posts

      Condenser-overview

      01/13/2021

      Condenser-overview

       Condenser (Condenser), which is a part of the refrigeration system, is a type of heat exchanger. It can convert gas or vapor into liquid, and transfer the heat in the pipe to the air near the pipe in a fast way. The working process of the condenser is an器2䀀ᅵ皥䖒皦즠Ʋ奌ི㲈Ʋ䌁皦ᮔDž༬皧奖ིЀ呄ᠾ鹨់༹皧ࠄ00령ꐱ댁珵뛐珵Љ䕄ྦ￿￿뤂ᐱ뚜珵ᴴᏩ呄ᠾ퍘ᒥ鹨់ᩄꋔྦ瑉浥巠皱㙲皦抐皱巠皱੨皦柘皱ᅵ皥ب巠皱㙲皦忈皱੨皦柘皱즠Ʋǜ勁皦즠ƲبǜV /펔B䌁皦 ᮔDž'鱤džၜ먢䇨珵呈ᠾ뤂ᐱ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲᠾ랖僧ؠ識�僬㣢ᐲ臆S㥲ᐲᬄğ識理艏S杴 識杴 㥲ᐲ

      What are the causes of air conditioning trip

      06/20/2020

      What are the causes of air conditioning trip

      What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

      Why Heat Pump Runs Constantly in Summer and What to Do?

      08/12/2023

      Why Heat Pump Runs Constantly in Summer and What to Do?

      Heat pumps are an excellent way to keep your home comfortable throughout the year. They are energy-efficient and can provide both heating and cooling to your home.

      Eight advantages of using frequency converter in air compressor

      09/07/2020

      Eight advantages of using frequency converter in air compressor

      In recent years, China’s call for energy conservation and emission reduction has become increasingly louder, and there has been an increasing demand for energy-saving equipment.

      How to Install an Industrial Exhaust Fan?

      11/14/2022

      How to Install an Industrial Exhaust Fan?

      Factory production emits a lot of waste gas, and there are many workers gathered. For the sake of worker health and safety concerns, some exhaust fans are installed in factories to discharge exhaust gas.

      So what factors will affect the stable operation of the equipment

      06/09/2025

      So what factors will affect the stable operation of the equipment

      At present, many companies use air-cooled chillers, which have the characteristics of simple installation and operation, compact structure, and relatively easy maintenance. The most important thing is that it is a highly efficient and energy-saving refrigeration equipment.

      High-end screw air compressors can be sold at high prices

      09/09/2020

      High-end screw air compressors can be sold at high prices

      1. Firmly funded enterprise users focus on comprehensive cost performance. They often use the functional price analysis method of technical economics in internal decision-making. This method adopts experts in product functions, brand, reliability, energy efficiency, environmental impact, price and other items.

      "Fire Eyes Gold Eyes" Training Guide: Genuine Danfoss Compressor

      07/12/2020

      "Fire Eyes Gold Eyes" Training Guide: Genuine Danfoss Compressor

      The current Danfoss compressor nameplate?

      Installation method of valve in refrigeration system of industrial chiller

      08/15/2020

      Installation method of valve in refrigeration system of industrial chiller

      In the refrigeration system of the industrial chiller, the main function of the valve is to control the flow and direction of the refrigerant. In daily use, the valve is often used.

      Mini Split vs. Window AC: Which Cooling System is Right for You?

      10/25/2023

      Mini Split vs. Window AC: Which Cooling System is Right for You?

      Choosing the right cooling system for your home or office is essential for creating a comfortable and pleasant environment. Two popular options are mini-split air conditioners and window AC units. Each system has its unique advantages and considerations.

      • Welcome to O&Kmarts

        Is there anything we can help?

        Email us
      • Feedback

      Join in

      Join in to enjoy exclusive discounts and give you greater discounts

      See More About O&Kmarts Member
      Sign up now

      Common Problem

      Payment Methods
      Shipping Guide
      Sales and Refund Policy
      FAQs

      About O&Kmarts

      About Us
      Membership

      Website Terms

      Privacy Policy
      Terms Of Use
      Bidding Agreement
      Review Rules

      Customer Service

      support01@okmarts.com
      service@okmarts.com
      hydraulic@okmarts.com
      +86-28-84166335
      GMT+08:00 Mon-Fri, 9:00 AM-7:00 PM
      Customer Feedback

      POPULAR PRODUCTS :

      KOYO Encoder SUMTAK Encoder Yaskawa Encoder Eltra Encoder Autonics Encoder Kuebler Encoder HENGSTLER Encoder MTL Encoder ELCO Encoder LS Mecapion Encoder GXMLW-1102001 RCH20D-2000/2-12MM-5/0-LD-VC-1-M4-S RI58-D/1024EF.47IF H40-8-1024ZV V23401-T2014-B209 25CJT0752 MHMF022L1V2M VE4025B1045 8E5K-22-X VA08H-760 BE67YEKMT CKD 4F310-10-L-DC24V CKD AMC-VL-X13 Commonwealth FP-108EX-S1-B D2D160-CE02-11 danfoss sy300a4cbe Ebmpapst VBH0500PTTLS K3G500PA2803 GEMU CH-6343 ha40101v4 Hitachi SHZ33LC2-S Honeywell TOEX-E0414 jt125ga y1 MDMA152P1G Mitsubishi NH56VNHT PFC0812DE Protechnic MGT4012WB-W28 sdr 120 12 Tecumseh TAH4524T TNB220FMCH TSB08751C-2NT3-1

      Disclaimer: All brand names, model or type numbers or marks listed on the website are owned by their respective manufacturers. These terms are used for identification purposes only and are not intended to indicate affiliation with OEM companies. Product pictures shown on the website are for illustrative purposes only and the actual item may vary in design, specification, etc. Confirm at the time of purchase if you are unsure.

      © eCommerce. 2017-2026. All Rights Reserved
      © eCommerce. 2017-2026. All Rights Reserved
      Press and drag the mouse to start taking a screenshot