Product series | EtherCAT Terminals |
Type/signal | single-ended |
Channels | 1 |
Signal (analog) | ±10 V |
Signal resolution (analog) | 12 bit |
Number of inputs | 1 (single-ended) |
Power supply | via the E-bus |
Input filter limit frequency | 1 kHz |
Weight | approx. 70 g |
Operating/storage temperature | -25…+60 °C/-40…+85 °C |
Relative humidity | 95 %, no condensation |
Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
Protect. rating/installation pos. | IP20/variable |
Approvals/markings | CE, UL, ATEX |
Ex marking | II 3 G Ex nA IIC T4 Gc |
Number of inputs: 1
Beckhoff Module EL3001
People who bought this item also viewed
Beckhoff Module EL2798
Beckhoff Module EL2652
Beckhoff Module KS1104
Beckhoff Module BC9050
Beckhoff Module CX1000-0111
Kuroda Module STV-16T
Beckhoff Module EL1862-0010
B&R Input Output Module ECCP60-01
Panasonic Servo Motor MHME504S1D
Panasonic Servo Drive MSDA303A1A
Delta PLC Digital I/O Module AH16AP11R-5A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Burgmann Mechanical Seal WB2-40
PHILIPS Capacitor 101 10000UF 63V
TEZUO Switch AFS-1
Recent related posts
-
07/26/2022
Classification of Vane Pumps
During a rotation cycle, the volume between adjacent vanes changes because of the rotor’s eccentric mounting position. This creates the pumping action.
-
08/19/2020
Knowledge of two air conditioners the same and different between evaporator and condenser
Condenser and evaporator are heat exchangers, which are widely used in refrigeration systems of high and low temperature alternating damp heat test chambers, constant temperature and humidity test chambers and other equipment.
-
08/17/2022
Permanent Magnet DC Motor: Types, Application, Selection Principle (2)
The following content is the second half of the previous article, and continues introducing the basic principles of permanent magnet brushed dc motors
-
06/25/2020
Basic knowledge of air energy
At present, the most commonly used vapor compression heat pumps, compressors, evaporators, condensers, and throttle valves are the four main components. Other auxiliary components include fans, four-way valves, liquid storage tanks, gas-liquid separators, copper pipes, and Protectors and electronic control parts used to ensure the normal operation of the machine, etc. Direct-heating models also include a water flow regulating valve. Schematic diagram of commercial air source heat pump system
-
11/22/2022
What are Centrifugal Fans Used for?
The centrifugal fan is a device that relies on the input mechanical energy to increase the pressure of the air and discharge the air.
-
09/01/2020
Brief Discussion on the Functions of Components of Skid-mounted Reciprocating Compressor Unit
Nowadays, most high-speed reciprocating compressors are assembled and complete sets in factories. They are pre-assembled to facilitate transportation and quickly establish contact with customers, greatly reducing installation time and costs...
-
05/13/2023
4 Ways to Test AC Compressor
The air conditioning compressor (AC compressor) is a key component in the air-conditioning system, and it is responsible for changing the refrigerant from a low-pressure state to a high-pressure state, thereby realizing the cooling effect of the air conditioner.
-
08/07/2020
What should I do if the refrigeration compressor returns oil
During the operation of the system, the lubricating oil is discharged from the compressor along with the refrigerant, and returns to the compressor after the cycle.
-
06/14/2020
Reliability-up (Compressors)
Reliability-up (Compressors)
-
05/04/2022
What is A Solenoid Valve?
Solenoid valve is an industrial equipment controlled by electromagnetism. It is an automatic basic element used to control fluid. It belongs to actuator and is not limited to hydraulic and pneumatic.