Category/version | Fieldbus systems, Profibus |
Type/signal | temperature (RTD, TC) |
Channels | 4 |
Value range (digital/encoder) | - |
Value range (analog) | Thermocouple |
Output current | - |
Communication | PROFIBUS |
Technologies/ Highlights | - |
Approvals | UL approvals |
Input/output specification (digital) | - |
Filter (digital) | - |
Signal resolution (analog) | 16 bit |
Measurement error/ uncertainty (analog) | > 0.1…0.5 % |
Sampling rate/ conversion time (analog) | < 0.1 ksps/> 10 ms |
Sampling type (analog) | - |
Ground reference (analog/encoder) | differential |
Sensor supply (encoder) | - |
Incr. limit frequency (encoder) | - |
IO-Link Port Class | - |
Housing | plastic housing, width 30 mm |
Wiring | 2-wire |
IP protection rating | IP65, IP66, IP67 |
Connection method (signal) | M12 |
Connection method (bus interface) | M12 |
Connection method (power supply) | M8 |
Explosion protection | not intrinsically safe |
Number of inputs: 4
Beckhoff Terminal Box Module IP3312-B318
People who bought this item also viewed
Allen-Bradley PLC 1785-ENET C
Beckhoff Module EL1012
Beckhoff Switch Module CU1521-0010
Beckhoff Module EL5101-0011
Beckhoff Module KL1408
Beckhoff Module EL7211-0010
Kuroda Module PTB-04S
Kuroda Module SD-120
B&R Controller Module 2DS100.60-1
SIEMENS Servo Motor 1PH8133-1JF02-2GA1
HENGSTLER Encoder AC58/1212AF.42SCA
Schneider I/O base PLC 170ADI74050
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NSK Linear Guideway LAH20AN
AirTAC Air Cylinder JSID63X75S
SCHMERSAL Switch TQ700-11S-40N-ST
Furnan Vane Pump PV2R1-17-FR
Galileo Water Pump QD6-32/3-1.1
Recent related posts
-
03/17/2022
What’s the Difference between Thermoelectric and Compressor Wine Coolers?
When it comes to the wine cabinet, it is very familiar to us, and some families have one. How much do you know about the wine cabinet?
-
07/16/2020
Analysis of the reason why cold storage should not be built underground
Many people think that building cold storage underground will have better thermal insulation effect than cold storage on the ground, because in the past, when the technology was backward, it was very common to choose cellars as crop storage. But from a commercial point of view, it is not scientific to blindly build the cold storage underground. The cold storage construction team stands from the perspective of consideration for customers
-
06/21/2022
Classification and How Does a Transformer Work?
Transformers are electrical devices consisting of two or more coils of wire that are used to transfer electrical energy by means of a magnetic field.
-
01/04/2021
Integrally Geared Compressors
Integrally Geared Compressors From Aaron M. Rimpel, ... Kolja Metz, in Compression Machinery for Oil and Gas, 2019 Petrochemical The oil and gas industry requires strict compliance with API 617 [4], and there is limited application for IGCs directly in 器2 䀀 ᅵ皥 䖒皦즠Ʋ㊔ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㊞ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ԥ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
07/01/2020
How to check the compressor body for cracks
How to check the compressor body for cracks In winter, it is relatively common for compressors to crack. I believe many people have ideas to prevent this kind of problem. In fact, it is not impossible, as long as we conduct a detailed inspection of the compressor body during normal maintenance, this problem can be avoided.
-
07/22/2020
The working principle of cooling and heating of air conditioning
In addition to the cooling function, the heating and cooling air conditioner also has the heating function. The biggest difference from a single-cooling air conditioner is that an electromagnetic four-way reversing valve is installed in the heating and cooling air conditioner.
-
08/04/2020
The warranty period of the main cold storage equipment is too short, how to solve it
When it comes to three guarantees, no one knows or knows. According to the national "Three Guarantees Regulations", as one of the main electrical appliances supporting our lives, the whole refrigerator has a one-year warranty
-
07/05/2022
Installation Of Magnet Pump
1.Dropping or subjecting the pump to strong impact may result failure. Handle the pump with care.
-
08/12/2020
How to choose the expansion valve of air-cooled chiller How to judge high and low pressure
How to choose and install the expansion valve for industrial chillers, screw chillers, air-cooled chillers, and chillers: The choice of expansion valve and the performance of the air-cooled chiller refrigeration system play an important role, the correct ¨ﰨ2
-
03/02/2021
Connection between Arduino and servo motor
The connection of the servo motor using Arduino is as follows: Connect the black wires on the two servo motors to the GND on the Arduino Connect the red wires on the two servo motors to the 5V pin on the Arduino Connect the yellow wire on the first motor to pin 8 on the Arduino