Category/version | analog input |
Type/signal | voltage |
Channels | 4 |
Value range (digital/encoder) | - |
Value range (analog) | 0...10 V (standard signal) |
Output current | - |
Nominal voltage | - |
Communication | K-bus |
Technologies/ Highlights | extended temperature range -25°C...+60°C, extended shock and vibration range |
Approvals | Ship approvals, UL approvals, Explosion protection |
PLC integrated | - |
Input/output specification (digital) | - |
Filter (digital) | - |
Signal resolution (analog) | 12 bit |
Measurement error/ uncertainty (analog) | > 0.1…0.5 % |
Sampling rate/ conversion time (analog) | > 0.1…1 ksps/< 10…1 ms |
Sampling type (analog) | multiplex |
Ground reference (analog/encoder) | single-ended |
Sensor supply (encoder) | - |
Incr. limit frequency (encoder) | - |
IO-Link Port Class | - |
Feedback (compact drive technology) | - |
Wiring | 2-wire |
Connection method (signal) | spring-loaded technique, plug-in connection level |
Connection method (bus interface) | - |
Explosion protection | not intrinsically safe, ATEX Zone 2 (gas) |
Safety technology/ functions | - |
Safety Architecture | - |
Safety Integrity Level (SIL) | - |
Performance Level (PL) | - |
Number of inputs: 4
Beckhoff Module KL3064
People who bought this item also viewed
Allen-Bradley PLC 1785-ENET C
Beckhoff Module EL2904
Beckhoff Module CX2550-0010
Beckhoff Module BC8050
Beckhoff Module BC9020
Beckhoff Module EL3312
Beckhoff Module EL9512
Yaskawa Servo Motor SGM-08U312
TECO Servo Drive TSTE10C
Autonics Rotary Encoder E50S8-200-3-N-5
Omron PLC CP1W-SRT21
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HONGFA Relay HF41F-12-ZS
Festo Sensor SIEN-M30B-NS-S-L
NACHI Check Valve OCH-G04-P2-10
Recent related posts
-
06/29/2020
How to calculate the number of Copeland compressors
How to calculate the number of Copeland compressors Copeland compressors are divided into L, C, 3S, 4S, and 6S series air-cooled compression and condensation units, which can be used as the main components of various refrigeration devices. The refrigerant can obtain various temperatures required for the preservation of fruits and vegetables, quick freezing of food or refrigeration. How to calculate the number of Copeland compressors?
-
08/19/2020
How to identify qualified air source heat pumps
Air-source heat pumps have the characteristics of energy saving, environmental protection, safety and easy management. They are favored by many schools, hotels, and families.
-
01/08/2024
Cooling Tower: Components, Working Principle, Types, Applications, and Precautions
A cooling tower is a device that uses the contact between water and air through the process of evaporation to dissipate waste heat generated in industrial or air conditioning systems.
-
08/20/2020
Introduction and characteristics of several throttling devices in refrigeration equipment
Among the four major components in the refrigeration system, the throttling device is one, and its function makes it have its own role.
-
01/20/2021
On-board oil-free air compressor, after reading these faults, you can solve them by hand
1. Excessive temperature rise Excessive temperature rise is a common fault during the operation of vehicle-mounted air compressors. Vehicle-mounted oil-free air compressors often operate at high temperatures,
-
03/04/2021
Advantages of servo motor
Precision: the closed-loop control of position, speed and torque, and the problem of out of step of stepping motor is solved; Speed: high speed performance, general rated speed can reach 2000 ~ 3000 rpm;
-
09/16/2022
What is Hydraulic Pump? (Function, Types, Application&Selection Method)
The basic hydraulic system components include oil tank, hydraulic pump, control valve, oil cylinder, connecting pipe and relief valve.
-
08/19/2020
Can the fresh air system, air purifier and air conditioner replace each other
1. Fresh air system Fresh air system is based on the use of special equipment on one side of a closed room to send fresh air to the room, and then discharge from the other side by special equipment to the outside,
-
08/08/2020
How to change the central air conditioner to be good for wind power
How to change the central air conditioner to be good for wind power 1. The conversion refrigeration of air conditioning becomes higher In order to control the balance function that runs during the operation of the parts, the central air-conditioning projﰨ2 䀀 湠疖 V ǜ
-
11/15/2022
How to Fix an Industrial Fan?
Industrial fans can effectively control the air circulation in industrial production workshops. However, industrial fans can also fail due to improper use and prolonged use.