Category/version | analog input |
Type/signal | power |
Channels | 2 |
Value range (digital/encoder) | - |
Value range (analog) | 0...20 mA (standard signal) |
Output current | - |
Nominal voltage | - |
Communication | K-bus |
Technologies/ Highlights | - |
Approvals | UL approvals, Explosion protection |
PLC integrated | - |
Input/output specification (digital) | - |
Filter (digital) | - |
Signal resolution (analog) | 16 bit |
Measurement error/ uncertainty (analog) | < 0.1% |
Sampling rate/ conversion time (analog) | < 0.1 ksps/> 10 ms |
Sampling type (analog) | multiplex |
Ground reference (analog/encoder) | differential |
Sensor supply (encoder) | - |
Incr. limit frequency (encoder) | - |
IO-Link Port Class | - |
Feedback (compact drive technology) | - |
Wiring | 2-wire |
Connection method (signal) | spring-loaded technique, plug-in connection level |
Connection method (bus interface) | - |
Explosion protection | not intrinsically safe, ATEX Zone 2 (gas) |
Safety technology/ functions | - |
Safety Architecture | - |
Safety Integrity Level (SIL) | - |
Performance Level (PL) | - |
Number of inputs: 2
Beckhoff Module KL3142
People who bought this item also viewed
Allen-Bradley PLC 1785-ENET C
Beckhoff Module BG1559
Beckhoff Module EL2521-0124
Beckhoff Module EL3062-0030
Beckhoff Switch Module CU1124
Beckhoff Module BC8100
Beckhoff Module BG1558
Beckhoff Module EL1808
B&R Controller Module 2DS100.60-1
Sanyo Denki Servo Motor L850T-012
Bosch Rexroth Servo Drive RZW01.1-037-NNN
Schneider Telemecanique PLC TSX07311612
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder SCF50X600
SOG Oil Seal TA 90*120*13
NKK Switch P-2022P
Shimadzu Gear Pump GPY-10R882
Recent related posts
-
08/03/2020
What are the thermal state parameters of the refrigerant
The working fluid is constantly changing its thermal state. The physical quantity describing the thermal state of the working fluid is called the thermal state parameter of the working fluid, referred to as the state parameter.
-
07/04/2020
Danfoss Miele Maneurop compressor MT40 market information
Danfoss Miele Maneurop compressor MT40 market information Meiyoule compressor model; Danfoss Meiyoule Maneurop compressor MT40; Meiyou MT40 horsepower: 3.3hp
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
The Package of Compressor and H series Gas Turbine
The Mitsubishi Hitachi Power Systems H-100 100 MW Class twin shaft gas turbine is ideally suited as a main refrigeration compressor driver for 4 to 6 mtpa LNG plant
-
06/16/2020
Danfoss expands portfolio of oil-free compressors with new TGS490
Danfoss expands portfolio of oil-free compressors with new TGS490 Danfoss, the world’s leading manufacturer of oil-free compressor technology, has expanded the oil free compressor portfolio with the introduction of the TGS490.
-
09/27/2022
What is a Hydraulic Vane Pump?
With the development of hydraulic technology, vane pump, as an indispensable power element, has been more and more deeply penetrated into various fields such as hydraulic systems
-
01/11/2021
Japan Daikin, Hitachi and Mitsubishi Electric air-conditioning compressor comparison
First, take a look at Daikin. The use of high and low pressure cavity scroll compressor and swing compressor
-
06/14/2020
Cold storage operation management and compressor common fault handling
Cold storage operation management and compressor common fault handling 1. Startup and preparations Before starting the machine, check whether the valves of the unit are in the normal starting state, and check whether the cooling water source is suffic 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ѳ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ
-
04/05/2023
10 Causes of AC Compressor Failure & 4 Ways to Prevent It
When the weather is very cold or hot, once the air conditioner fails, it will be miserable. So it is necessary to know the possible faults of an air conditioner compressor and some preventive ways in advance.
-
08/08/2022
What is Synchronous Motor
Synchronous motors like induction motors (i.e. asynchronous motors), are a common type of AC motor.