There is no price at present, you can Request a Quote
Power: 18.5KW
Power: 380V/440V-50HZ/60HZ
Cylinder diameter (mm): 70
Stroke (mm): 55
Number of cylinders: 4
Exhaust volume: 73.6m3/h
Foot mounting size: 305mmx381mm
Dimensions (mm): length 737 width 456 height 449
Suction pipe inner diameter (mm): 54
Exhaust pipe inner diameter (mm): 28
Oil charge (liter): 4.5
Suitable for refrigerant: R134a R404A R507A R407C We can also provide the following models
GSD80120VBR5-1
GTD80137VBYR5
GSD60137VAR6-2
GTD60485VBR3
GUD60182VAR6
GSU60154VLB432
GUD60235VLR4-1
GUD60235VLYB4-2
GYD60385VLYR5
GYU60120VLYB632
GTD80485VBYR2-2
GUU60182VLYR5-2
CSH96103-280Y
GED60295VWB3-1
GSD60137VBYB5
GMD80421VWYR2
GYD60137VBYB3-1
GSD60485VLB2-2
GTD60182VLB6-2
GED60182VWR332
CSH8553-110-40D
GSU60235VLYB3
GED60137VBYB3
GSU60137VLYB5-1
GSD60120VLR2-2
GUU60154VLB4-1
GED60421VW
GED80235VLB5-1
GED80421VBYR6-2
GED60182VBR5-1
GYD60182VAR5-2
GMD60421VBYR2
GMD80154VAB3-1
GTD80421VAYR6
GMD60137VAYB6-1
GSD80235VWYB332
GED80154VBYR5-1
GUD80154VAYR6
GSD80154VAY
GYD80485VLYB4
GED60421VWB2-1
GMD80120VLYB6
GED80385VLB632
GUU60120VLR4
GYD80485VBYR3-2
GMD60385VAYR2-1
GMD60385VBR5
GMD80485VBYR332
GED60137VBYR5-1
GED60235VWB2-2
GED60120VBYR632
GMD60235VAYB2-1
GSD80421VWR4-2
GMD80295VBR232
4EESP-6
GTD80182VLYR4-2
GUD60385VAB3
GMD60235VA
GUD60154VLR6-2
GSD80182VBR2-1
GYD60295VAYB3
GED80295VWYB3-2
GTD80485VBYB3
GYD60182VLYR4-2
GSD60295VLR532
GED60154VLB232
GYD80154VAB532
GUU60182VLR3
GMD60182VLR4-1
GSD60120VAR3-2
GMD80385VWB2-1
GUD60421VBYR4
For more information,please contact us freely
Bitzer Compressor 4H-25.2Y
There is no price at present, you can Request a Quote
People who bought this item also viewed
Bitzer Compressor 6H-35.2
Bitzer Compressor 2CC-4.2
Bitzer Compressor 4VCS-6.2-40P
Bitzer Compressor 4DC-5.2-40P
Tecumseh Compressor CAJ2464Z
Daikin Compressor 1GDY23AXD
Hitachi Compressor THU33WC6-U
Sanyo Compressor C-SC603H8J
Bel Signal Transformer DP-241-4-24
Emerson Alco Expansion Valve TCLE2MC
Hager Contactor EW007_C
ROYAL Fan UTL806C
GAST Electric Motor 8AM-FRV-30A
Bosch Filter 0986AF2900
Danfoss Sight Glass SG10N
DAIKIN Expansion Valve Coil RXD25
KEMET Capacitor 400V 47NF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder CAC4-A-63-100
HONGFA Relay HFE20-3-12-1HST-L2(359)
Panasonic Servo Motor MFMA252S1G
TCG Electric Motor TCH32-2200-30-60S
SMC Sensor PFM725S-C6L-A-M
PARKER Filter 933734Q
Recent related posts
-
04/28/2022
What is A Contactor?
Contactors are divided into AC contactors (voltage AC) and DC contactors (voltage DC). They are used in power, power distribution and electric field combination.
-
06/14/2020
Compressed air technology is becoming more efficient
Compressed air technology is becoming more efficient Compressed air technology is becoming more efficient Compressed air is the most widely used in industry and commerce besides electricity Energy is widely used because it is easy to operate, fast, hig 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ܲ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/14/2022
FAQs on Hydraulic Motor
According to the rated speed, hydraulic motors are divided into: high-speed hydraulic motors (rated speed higher than 500r/min), including gear, vane and axial piston types
-
06/14/2020
The reasons for the high temperature of the compressor discharge are
The reasons for the high temperature of the compressor discharge are (1) The clearance in the compressor cylinder is too large; (2) The suction and exhaust valves and piston ring of the compressor are damaged; (3) The compressor safety bypass valve 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
06/14/2020
Scroll compressor March sales continue to decline
Scroll compressor March sales continue to decline In March 2020, the total output of the scroll compressor industry was 231,000 units, a year-on-year decline of 27.01%, an increase of 118.75% from the previous month
-
08/29/2023
Heat Pump vs Central Air: Which One is Right for You?
When it comes to cooling your home, you have two main options: a heat pump or a central air conditioner. Both systems work to remove heat from your home and circulate cool air throughout, but they operate in different ways.
-
08/09/2023
Heat Pump Not Working in Cold Weather: Causes and Solutions
A heat pump is a popular heating and cooling system that works by transferring heat from one place to another. It can heat your home in the winter and cool it in the summer, making it a versatile and cost-effective option for many homeowners.
-
08/13/2020
Water-cooled chillers need to be cautious when choosing cooling towers
In many special use environments, companies need to apply water-cooled chillers. Because water-cooled chillers need the help of cooling towers during operation, they need to follow the
-
09/07/2020
How to choose the first flange sealing surface form of the pressure vessel using flange connection
The flange welded by the connecting pipe on the pressure vessel cylinder to the flange is the first flange connected to the pressure vessel flange, and the flange that is matched with it is not counted as the first flange, and other flanges.
-
07/16/2020
Heating principle of drying oven
Heating principle of drying oven Everyone knows that the oven is a kind of drying equipment, so how does the oven generate a heat source to quickly achieve the drying effect? Let us take this question to consult some Lutheran.