There is no price at present, you can Request a Quote
BREVINI Reduction Drive Gearbox Speed Reducer SB2C2250
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Servo Motor HC-SF52G1H
JSCC Speed Reducer 90GK7.5HK
GGM Electric Motor K9IP200FH
BANDO Belt RIB ACE 7PK 1835
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
INVT VFD Frequency Converter CHE100-011G-4
CKD Switch MOH
VIGOR PLC VB-2PT
Schneider Sensor XS1N30PB340
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/09/2020
Several factors that determine the normal displacement of an air compressor
The displacement of an air compressor is actually a manifestation of the quality and efficiency of the equipment to a certain extent, and it is usually affected by several factors.
-
08/13/2020
How to choose the internal machine for cold storage Choose air cooler or exhaust pipe
Most of the cold storages we make are divided into many types, such as high temperature storage, low temperature storage, ultra low temperature storage, etc. So how to choose the internal machine of the cold storage?
-
03/10/2024
Hydrogen Fuel Cell Thermal Management: Two Main Ways Explained with Diagrams
Proton exchange membrane fuel cells (PEMFC) have the advantages of high efficiency, cleanliness, zero emissions, etc.
-
09/01/2021
What is VFD?
A VFD (Variable-frequency Drive, frequency converter) is a power control device that uses frequency conversion technology
-
01/02/2021
Uncover counterfeits - by product type-Coils
Fake coils for solenoid valves could cause serious damage to your refrigeration system. Identifying Danfoss genuine coils is not difficult – but attention to detail is key here.
-
02/09/2023
How to Replace a Blend Door Actuator?
Blend door actuators control the temperature and flow of air in the vehicle. If your vehicle only releases cold air, or you can't change the airflow
-
07/18/2020
Explanation of the excellent performance of each component of the screw chiller
The application of screw refrigeration compressors is becoming more and more common, and some of them have entered the period of frequent failures. When the abrasion of the female and male rotors, body, and exhaust end seat of the refrigeration compressor reaches above 0.65rnm, vibration will occur when the refrigeration compressor is running, the sound is abnormal, the cooling capacity is reduced, and the compressor cannot work normally.
-
06/13/2020
Daily cold storage system maintenance method
Daily cold storage system maintenance method For large-scale refrigeration equipment such as cold storage, we should usually do daily inspection and maintenance in order to quickly eliminate the abnormal operation of the cold storage, thereby reducing th 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹
-
06/21/2020
Causes and judgement of centrifugal compressor surge
Causes and judgement of centrifugal compressor surge Causes of centrifugal compressor surge ①Flow<img src="{{media url="Causes_and_judgement_of_centrifugal_compressor_surge.jpg"}}" alt="" /> Each centrifugal compressor corresponds to a curve between outlet pressure P and flow rate Q at different speeds n, as shown in Figure 2.