Series | H21B Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R22 |
Generation | Second Generation-Basic Standard Model |
Family | Model B Reciprocating |
Nominal Capacity (BTU/Hr) | 30,000 BTU/Hr |
Motor Type | AL 3 Phase-Across the Line |
Motor Protector | Internal Line Break |
Electrical Characteristics | 230/200-3-60 (220/200-3-50) |
Mounting Feet Dimension (Inches) | 8.8 x 6.1 |
Bristol Compressor H21B303DBLX
There is no price at present, you can Request a Quote
People who bought this item also viewed
Samsung Compressor NC4AV80ALR
Mitsubishi Compressor RB233YABC
Tecumseh Compressor TFH4525Y
Copeland Compressor ZMD26KVE-TFD-984
Bristol Compressor H24B25QABKA
Bristol Compressor H71J363DBL
Bristol Compressor H2NG244DPEF
Bristol Compressor H29B28UDBV
Danfoss Compressor MT81HP4AVE
Daikin Compressor JT95GABV1L
Danfoss Compressor MTZ28JE4AVE
Danfoss Compressor 120G0014 VZH117AGANA
Tamura Transformer 3FS-220
Danfoss Expansion Valve 068U2058
Schneider Contactor LP1D6511BDC
Sanyo Denki Fan 9WP1212L101
Samsr Electric Motor SS2302A42A-8
PARKER Filter G04189
Danfoss Sight Glass SGP10SN
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
YAIZ Air Conditioner KFRD-35GW-080-E3
OKTY Oil Seal TC(NBR)60*74*8
ARK Air Cylinder KDVU32-20-A-P-A
Recent related posts
-
08/21/2020
Three tips for cold storage board installation
n the refrigeration industry, cold storage panels with relatively low technical requirements have attracted a large amount of personnel and capital investment. The choice of the quality of the cold storage board is very important for the cold storage,
-
05/01/2023
What are Refrigeration and Air-Conditioning Compressor Heaters Used For
The compressor heater (oil heater, crankcase heater, compressor heating belt) is a part of the refrigeration compressor.
-
07/28/2020
Common faults and solutions of screw chillers
Low voltage overrun protection:<br></br> Solution: Replace or clean the filter element; clean the suction port filter.<br></br> Dirty or ice blockage at the inlet of the expansion valve:<br></br> Solution: Dirty blockage: remove the expansion valve and clean it. Ice blockage: replace the filter drier and run again
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/18/2020
Copeland compressor semi-closed series product introduction
L, C, 3S, 4S, 6S Copeland semi-hermetic refrigeration compressors are high-quality and high-performance products produced by advanced technology and equipment. The air-cooled condenser adopts secondary flanged fins and mechanical tube expansion technology.
-
03/20/2022
6 Things About Your Wine Cooler Not Working
Now the wine cabinet not only has the function of storing wine but also has the role of decoration.
-
01/23/2024
Single Fan and Dual Fan for Household Central Air Conditioning Outdoor Unit: How to Choose?
Central air conditioning generally includes indoor units and outdoor units. For the selection of outdoor units, there are generally single fan and double fan types to choose from. So which one is better to choose?
-
03/09/2021
Servo driver related parameter setting method
Position feedforward gain: set the feedforward gain of the positioning loop. The larger the set value is, the smaller the position delay isand the larger the feedforward gain of the position loop is, the high-speed response of the control system will rise, but the position of the system is unstable and prone to oscillation. When high response characteristics are not required, this parameter is usually set to 0, indicating the range of 0 ~ 100%.
-
09/07/2020
Application of pressure dew point in compressed air system
The air that is reduced in volume and increased in pressure by the mechanical movement of the air compressor is called compressed air. Compressed air is an important power source and is widely used in many industrial fields such as machinery, metallurgy, electronics, electric power,
-
07/27/2021
7 Ways to Save Energy on Your Air Compressor
As one of the power sources of manufacturing and production enterprises, compressed air requires continuous operation of equipment to ensure the stability of air supply pressure