There is no price at present, you can Request a Quote
Series | H23A Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R22 |
Generation | Fourth Generation-Basic Standard Model |
Family | Model A Reciprocating |
Nominal Capacity (BTU/Hr) | 58,000 BTU/Hr |
Motor Type | PSC Permanent Split Capacitor |
Motor Protector | Internal Line Break |
Electrical Characteristics | 230/208-1-60 |
Mounting Feet Dimension (Inches) | Offset Mounting Rail |
Shipping cost is not included
The Bristol Compressor is high quality!
Bristol Compressor H23A583ABCL
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Compressor TNB220FMCH
Copeland Compressor ZR61KCE-TFD-523
Tecumseh Compressor CAJ2446Z
Bristol Compressor H23B263ABKA
Bristol Compressor H25D62QDBEA
Bristol Compressor H24B15QABJA
Bristol Compressor H7BG144DBEE
Toshiba Compressor PH260X2S-8KUC
Copeland Compressor ZR72KCE-TF5-522
Hitachi Compressor E855DH-80D2YG
Tecumseh Compressor AE4425Z
TRIAD Transformer F-355X
Parker Sporlan Expansion Valve ERVE-2-GA
Schneider Contactor LC1D245F5C
Y.S.TECH Fan FD1230107B-2N
Danfoss Sight Glass SGR 014-0005
KEMET Capacitor R463I310000M1K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Gree Air Conditioner KFR-72LW-(72551)FNBc-A2
SIEMENS Relay LZX:PT5A5L24
HAWK Water Pump XXT7015
Makita Fan UB001GM101
Littelfuse Fuse 0498070.M
PIZZATO Switch FX 1896
Recent related posts
-
06/22/2020
What should I do if the air conditioner is not cooling
What should I do if the air conditioner is not cooling? These days of high temperature, just want to stay in the air-conditioned room to eat watermelon to escape the heat. Everyone tells a joke, "My life is given by the air conditioner." When the air conditioner is broken, how to deal with it if it is not cooled? Is it possible to solve it by adding fluoride? Let's learn it and don't be fooled by others. <img src="{{media url="magefan_blog/What_should_I_do_if_the_air_conditioner_is_not_cooling.jpg"}}" alt="" />
-
06/26/2020
What is the refrigerator compressor used for
Refrigerators use evaporative cooling or vaporization to absorb heat to achieve the purpose of refrigeration. The throat of the refrigerator is filled with a refrigerant known commercially as Freon, commonly known as refrigerant. A commonly used one is difluorodichloromethane, which is a colorless, odorless and non-toxic gas with a boiling point of 29°C. Freon is pressurized by the compressor when it is in a gas state.
-
06/14/2020
Description of refrigeration compressor maintenance methods
Description of refrigeration compressor maintenance methods This article mainly describes the related content of the maintenance methods of refrigeration compressors
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
Refrigeration compressor classification overview
Refrigeration compressor classification overview The compressor is the core equipment in the refrigeration system. Only by converting electrical energy into mechanical work and compressing the low-temperature and low-pressure gas refrigerant into high- 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧
-
09/27/2023
Industrial Water Chiller Repair: Troubleshooting and Maintenance Tips
An industrial water chiller is a critical component in many manufacturing and industrial processes. It is responsible for cooling various types of equipment, which helps to prevent overheating and maintain optimal performance.
-
06/01/2023
How to Check AC Compressor: A Comprehensive Guide
The air conditioner compressor, also known as the AC compressor, is an essential component of your home's HVAC system.
-
06/17/2020
What are the three tubes of refrigerator compressors used for
What are the three tubes of refrigerator compressors used for 1. The general refrigerator compressor has three pipe ports; 2. The exhaust port discharges the compressed refrigerant to the condenser and then dissipates heat. The temperature of th 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋ
-
08/09/2020
What is the reason that the temperature of the freezer cannot drop
It is a common phenomenon that the temperature of the supermarket freezer does not drop and the temperature drops slowly. Now I will briefly analyze the reasons for the slow temperature drop, hoping to bring some help to friends in the industry.
-
09/07/2020
The most common problems and solutions of adsorption dryers!
Adsorption dryer is a very important part of the compressed air purification process. Whether it operates normally and whether it is running well is directly related to the quality of compressed air.