There is no price at present, you can Request a Quote
Series | H25A Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R22 |
Generation | Inertia Series-Standard Model |
Family | Model A Reciprocating |
Nominal Capacity (BTU/Hr) | 32,000 BTU/Hr."Quiet" |
Motor Type | AL 3 Phase-Across the Line |
Motor Protector | Internal Line Break |
Electrical Characteristics | 460-3-60 (380/415-3-50) |
Mounting Feet Dimension (Inches) | 8.8 x 6.1 |
Shipping cost is not included
The Bristol Compressor is high quality!
Bristol Compressor H25A32QDBEX
There is no price at present, you can Request a Quote
People who bought this item also viewed
Mitsubishi Compressor AGT201A311SD
Mitsubishi Compressor TNB220FMCH
Mitsubishi Compressor NN37VAAMT
Bristol Compressor H23A543DBF
Bristol Compressor H82J273ABCA
Bristol Compressor H23A383DBEA
Bristol Compressor H20J353DBV
Danfoss Compressor MTZ22JC4AVE
Hitachi Compressor FM600DHD-90D1
Panasonic Compressor 2K25S3R225A
Bristol Compressor H24B25QABKA
TRIAD Transformer FP230-50
Siemens Contactor 3RT2018-2UB42
ROYAL Fan UTL121A
Donaldson Filter P153551
Danfoss Sight Glass SGH 16S
Samsung Expansion Valve Coil 2.2C-05
KEMET Capacitor TAJA155K016RNJ
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COSEL Power Supply LFA100F-12-SR2
P+F Pepperl Fuchs Sensor NBN8-18GM60-A2
ESAB Welding Wire OK Autrod 317L
NMB Sensor PRN01/PRN02-20M
Ferraz Shawmut Fuse PC92UK15C350TF
CKD Air Cylinder SCM-00-50B-75
YUKEN Vane Pump PV2R23-116-53-F-RAAA-40
Recent related posts
-
06/21/2020
How often does the freezer cool
It is normal for the freezer to cool once every 10-20 minutes. The cooling time of the freezer is not fixed, it is related to the set temperature, usage, storage items and service life. If it's a new refrigerator you just bought, you set it to 4th gear cooling, you may have to wait a few hours before cooling, this is because the new refrigerator is synchronized with the room temperature, cooling requires a process. <img src="{{media url="magefan_blog/How_often_does_the_freezer_cool.jpg"}}" alt="" />
-
04/04/2024
Analysis and Solutions to AC Servo Motor Vibration Faults
AC servo motors are used in closed environments and are usually not easily damaged. But if the AC servo motor has vibration failure, what is the reason?
-
08/02/2021
Daikin Vs. Hitachi Air Conditioners
In summer, what is the best-selling electrical appliance in the electrical market? Air conditioners can be said to be one of the indispensable appliances in the family.
-
09/17/2020
Application of industrial wireless remote control in industrial driving
The application of industrial wireless remote control in industrial driving Industrial wireless remote control technology mainly uses wireless transmitters to transmit human operation instructions to a remote receiving system through digital encoding and encryption. The receiving system restores the control instructions after decoding and conversion to achieve control of various mechanical equipment Control;
-
02/26/2023
Types and Characteristics of Common Air Cylinders
Types and Characteristics of Common Air Cylinders, Pen Cylinder, Thin Cylinder, Free Mounting Cylinder, Double-Shaft Cylinder, Slide Cylinder, Rodless Cylinder
-
09/22/2020
Compressed air dewatering, oil removal and dust removal multifunctional filter
Compressed air degreasing, water removal and dust removal filter (purification equipment) Sometimes, connecting a piece of equipment to a compressed air supply station cannot solve the quality of compressed air.
-
06/21/2020
Working principle of steam compressor_steam compressor application
Working principle of steam compressor_steam compressor application Working principle of steam compressor After the steam is filtered by the filter, clean steam then enters the host cavity through the intake valve, and the volume of the cavity changes from large to small to compress the steam. The volume of the cavity is changed by the rotor rotating under the drive of the motor. <img src="{{media url="Working_principle_of_steam_compressor_steam_compressor_application.jpg"}}" alt="" />
-
06/13/2020
This is the reason for the overheating of refrigeration compressor exhaust~!
This is the reason for the overheating of refrigeration compressor exhaust~! The main reasons for the exhaust temperature overheating are as follows: high return air temperature, large motor heating capacity, high compression ratio, high condensation pre 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁
-
12/06/2023
How to Distinguish Different Types of Fans in Data Centers
Without fans, it is impossible to ensure that equipment components operate at a constant temperature. Long-term continuous high-temperature operation of equipment will accelerate the aging of components and shorten the life cycle of equipment operation.
-
06/24/2020
What to do if the refrigerator does not cool in winter
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.