Series | H70R Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R407C |
Generation | Basic Standard Model |
Family | Scroll (>42k) |
Nominal Capacity (BTU/Hr) | 45,000 BTU/Hr |
Motor Type | AL 3 Phase-Across the Line |
Motor Protector | Internal Line Break |
Electrical Characteristics | 460-3-60 (380/415-3-50) |
Shipping cost is not included
The Bristol Compressor is high quality! We can also provide the following models
H23B153ABCY
H82J173ABCR
H23B243ABCA
H29A623DBVK
H25B28QDBLD
H22J413DBFD
T89A515BBCJ
H79B35UABHH
H25D10QDBEC
H82J18UABCC
H20B283ABJJ
H84J353DBVR
For more information,please contact us freely
Bristol Compressor H70R453DBE
Brand name : |
Bristol |
|||||||||||||||
Series : |
H70 |
|||||||||||||||
Model : |
H70R453DBE |
|||||||||||||||
Refrigeration application : |
High temperature |
|||||||||||||||
Refrigerant : |
R407C |
|||||||||||||||
Generation : |
|
|||||||||||||||
Family : |
Scroll (>42K) |
|||||||||||||||
Capacity : |
45000 BTU/HR |
|||||||||||||||
Motor type : |
AI 3 Phase-Across the line |
|||||||||||||||
Motor protector : |
Internal line break |
|||||||||||||||
Electrical characteristics : |
460-3-60 (380/415-3-50) |
|||||||||||||||
Meeting Feet Dim : |
|
|||||||||||||||
Oil charge : |
70/2.1 |
|||||||||||||||
Weight (net) : |
78.0/35.5 |
|||||||||||||||
DIMENSIONS in./mm : |
11.7/296.3X16.6/422.3X18.2/461.3 |
|||||||||||||||
Color : |
black |
Model |
@45/130 |
@45/100 |
@45/110 |
Electrical Data |
Displacement |
|||||||||||
Capacity |
Motor Input WATTS |
EER/COP |
Capacity |
Motor Input WATTS |
EER/COP |
Capacity |
Motor Input WATTS |
EER/COP |
RLA |
LRA |
MCC |
IN3 /REV |
CM3 /REV |
|||
BTU/HR |
WATTS |
BTU /HR |
W /W |
BTU/HR |
BTU/HR |
BTU/HR |
BTU/HR |
|||||||||
400 VOLTS |
36394 |
10679 |
3450 |
10.5 |
3.1 |
44923 |
2425 |
18.5 |
42377 |
2730 |
15.5 |
6.4 |
47 |
10.0 |
3.60 |
58.97 |
Bristol compressors reduce costs across the entire product lifespan in the application.
They support system design for high efficiency performance and for the use of alternative refrigerants for light commercial, commercial and industrial HVAC applications such as rooftops units, chillers, process cooling, packaged units etc.
Key Features
Environmental protection
Energy efficiency leader, boosting the upgrade of the green household appliances
Efficient
18-slot motor with a 6-pole winding, creating the ultimate ultra-quiet technology in the industry
Bristol Compressor H70R453DBE
People who bought this item also viewed
Tecumseh Compressor AEZ4430Z
Tecumseh Compressor RK5480Y
Mitsubishi Compressor RB247YFY
Bristol Compressor H23B243ABKA
Bristol Compressor H82J37BABCA
Bristol Compressor R92J183ABKA
Bristol Compressor H23A423ABKA
Sanyo Compressor C-SCX453H38B
Tecumseh Compressor AWA5532EGH
Hitachi Compressor SHX33SC4-U
Panasonic Compressor 5VS295EZA21
Delixi Transformer BK-150
Danfoss Expansion Valve 067N4010
Siemens Contactor 3RT2017-1AB01
SUNON Fan MF50152V2-1000C-A99
XD Electric Motor XD3IK15GN-C
MAHLE Filter LX3607
Danfoss Sight Glass SGN22S
FUJITSU Expansion Valve Coil DC12V
CDE Capacitor 25V 500UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Servo Motor MHME202GCGM
Siemens Contactor 3RT1476-6AM36
UniOhm Resistor 1206W4J0330T5E
SMC Proportional Valve ITV3010-314L5
FUJIGEN Tool for Metal Cutting MBM4513T
Recent related posts
-
07/20/2020
Characteristic description of abnormal temperature of compressor
The condensing valve is a valve used to remove condensate and air from the system, and the potential heat loss is large. The thermal imaging camera can monitor the working condition of the condensing valve to determine the steam utilization efficiency and avoid energy waste and leakage accidents
-
07/05/2020
Hitachi 6HP Inverter Compressor-Compressor
Hitachi 6HP Inverter Compressor-Compressor Why is frost formed between the electronic expansion valve and the compressor? A customer asked: The compressor is suddenly not cooling, and the electronic expansion valve is frosted to the compressor. Is there any relationship between the two before?
-
08/21/2020
Use cooling water circulation to avoid several problems
In the actual operation of the chiller system, there are often the following misoperations: 1. Failure to close the inlet valve of the condenser on the chiller that does not need to be opened before starting the machine, causing water leakage.
-
05/18/2022
PLC Analog Input
PLC analog inputs usually use voltage signals in the range of 20 volts and current signals in mA. Each PLC manufacturer has I / O modules to process these types of signals
-
02/06/2022
Why Refrigeration Compressor not Work but Operate Normally
In some cases, you would find that the compressor motor starts and runs normally, but it cannot compress the refrigerant.
-
07/28/2020
Overview of refrigeration compressor classification
The compressor is the core equipment in the refrigeration system. Only by converting electrical energy into mechanical work and compressing low-temperature and low-pressure gaseous refrigerant into high-temperature and high-pressure gas can the refrigeration cycle be ensured
-
06/27/2023
DIY Guide to Testing and Replacing Your Refrigerator Compressor Start Relay (Save Money and Time)
A refrigerator compressor start relay is a device responsible for starting the compressor of a refrigerator. When this component fails, the refrigerator will not cool properly, causing food to spoil.
-
09/11/2020
Summary Essentials of water treatment for central air-conditioning chillers
Looking at the management of central air-conditioning throughout the country, it is found that very few are well managed, and all have problems of one kind or another to varying degrees. The main problems are described as follows: 1. Problems caused by the unreasonable design of the design department
-
09/06/2020
Characteristics and Control of Exhaust Noise of Air Distribution Valve in Pneumatic System
In a pneumatic system, the air intake and exhaust of the cylinder are controlled by an air distribution valve, and the noise generated by the air discharged into the atmosphere through the exhaust port of the distribution valve is often greater than the noise generated by any part of the pneumatic system. And cause serious damage and pollution to the operators and the surrounding environment [2].
-
07/19/2020
Basic knowledge of refrigeration compressor
After shutting down, stop for at least 3 minutes before starting again to eliminate the pressure difference between the compressor inlet and outlet. Because in the case of a large pressure difference, the starting torque of the motor will increase, causing the current to rise to a certain level, the protector will act and the compressor cannot continue to run.