There is no price at present, you can Request a Quote
Series | H73B Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R407C |
Generation | Fourth Generation – Basic Standard Model |
Family | Model B Reciprocating |
Nominal Capacity (BTU/Hr) | 35,000 BTU/Hr."Quiet" |
Motor Type | PSC Permanent Split Capacitor |
Motor Protector | Internal Line Break |
Electrical Characteristics | 220/240-1-50 |
Mounting Feet Dimension (Inches) | 7.5 x 7.5 |
Shipping cost is not included
The Bristol Compressor is high quality!
Bristol Compressor H73B35QABKA
There is no price at present, you can Request a Quote
People who bought this item also viewed
Tecumseh Compressor RK5480Y
Mitsubishi Compressor RS2527ESH14 ALA201A025
Tecumseh Compressor AEZ4430Z
Tecumseh Compressor TRK5512Y
Bristol Compressor H22J333DBV
Bristol Compressor H21J18UABC
Bristol Compressor H2NG244DREF
Bristol Compressor H24B25QDBEA
GMCC Compressor PA290X3CS-4MU1
Daikin Compressor JT1G-VDKYR
Toshiba Compressor PH240X2CS-8FTC
Hitachi Compressor TH508MV-C9EU
Delixi Transformer JBK-63VA
AEG Contactor LS07-22
Sanyo Denki Fan 9G0948J1011
Oriental Motor Electric Motor PK599AW
MAHLE Filter LX3809
Danfoss Sight Glass SGN19
ABB Capacitor CLMD53-30KVAR 480V 50HZ
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Contrinex Sensor DW-AD-613-M8-121
Ebmpapst Fan 514F
Recent related posts
-
11/07/2021
The Era of Intelligent Building Management Comes with Siemens HMI + KNX
Siemens is a leading electronic and automation product manufacturer in the world. Based on its advanced human-computer communication technology and brand development concept
-
07/23/2020
R410a and R22 refrigerant comparison application and installation specifications
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.
-
08/21/2020
A newly installed air conditioner trips as soon as it is plugged in. What's the matter
This question is about the first use of newly purchased appliances. This question actually asks two questions: First, the newly installed air conditioner trips as soon as it is plugged in. Why?
-
09/11/2020
What are the tips for using screw air compressors
The set unloading pressure of the air compressor pressure regulator is adjusted with the upper adjusting bolt. Turn the bolt clockwise to increase the unloading pressure, and rotate it counterclockwise to reduce the unloading pressure. The differential pressure value is adjusted by the differential knob at the bottom. Turn it counterclockwise, the pressure differential value of the air compressor decreases, and clockwise
-
01/16/2023
How does Variable Valve Timing Work?
The valve timing system of a traditional engine is a mechanical system in which the valve timing (i.e., valve opening and closing) remains unchanged.
-
06/13/2020
Identify the failure of a fully enclosed refrigeration compressor in three minutes
Identify the failure of a fully enclosed refrigeration compressor in three minutes 1. How to identify the three binding posts on the casing of the hermetic compressor?
-
07/21/2020
Ten basic performance parameters of refrigeration compressors (technology sharing)
Under a certain working condition, the gas mass delivered from the suction end to the discharge end per unit time is called the compressor mass air delivery under this working condition, and the unit is. If calculated according to the volume of the inhalation state, the volume of the air delivery is, and the unit is then
-
09/30/2022
Three Control Methods of Servo Motor
There are three types of <strong>servo motor control</strong> modes (<strong>servo motor control techniques</strong>)
-
06/19/2020
How good is the air conditioning dehumidification
Nowadays, the temperature of some air conditioners is set actively by the manufacturer during dehumidification. Under the dehumidification method of this type of air conditioner, the control circuit will first check the room temperature, and then set the operating temperature policy value. The setting value of the factory plan is usually the policy value of the operation arrival It is 2 degrees lower than the room temperature. If the setting is too high, the dehumidification effect is not significant. In order to prevent overheating and lowering the room temperature during dehumidification, this set value is usually judged. At this time, we do not need to set the temperature, just open the air conditioning dehumidification function.<img src="{{media url="How_good_is_the_air_conditioning_dehumidification.jpg"}}" alt="" />
-
03/17/2024
What Is a Closed Loop System (Servo System / Servomechanism)?
As shown in the figures above, the closed-loop control system has a feedback device to feedback the position of the servo motor, but the open-loop control system does not.