There is no price at present, you can Request a Quote
Series | H82J Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R410A |
Generation | Third Generation – Basic Standard Model |
Family | Benchmark Model Reciprocating |
Nominal Capacity (BTU/Hr) | 37,000 BTU/Hr |
Motor Type | AL 3 Phase-Across the Line |
Motor Protector | Internal Line Break |
Electrical Characteristics | 460/380-3-60 (380/415-3-50) |
Mounting Feet Dimension (Inches) | 7.5 x 21.5 |
Shipping cost is not included
The Bristol Compressor is high quality!
Bristol Compressor H82J37MDBVH
There is no price at present, you can Request a Quote
People who bought this item also viewed
Tecumseh Compressor CAJ2446Z
Mitsubishi Compressor LNB42FSCMC
Mitsubishi Compressor TNB220FMCH
Bristol Compressor H22J253DBL
Bristol Compressor H23A63QDBNA
Bristol Compressor R92J183ABKA
Bristol Compressor H20J353DBL
Mitsubishi Compressor SNB092FFBH
Danfoss Compressor CXH140A4ALA
Danfoss Compressor 105G6772
GMCC Compressor HSM145V1UFZ
Bel Signal Transformer 241-7-28
Emerson Alco Expansion Valve TRAE40MC
Siemens Contactor 3RA2446-8XF32-1AG2
Shengkwei FAN SK92AP-22-1
JOHNSON Electric Motor 32070
PALL Filter HC9600FKS4H
Danfoss Sight Glass SGN 12S014-0183
MURATA Capacitor DEBB33F471KA3B
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Nidec Fan E0720H24B8AS-55
COKERY Belt 284-2GT
NKK Switch M-2028LB
CHANTO Air Cylinder ASR63X200
Recent related posts
-
09/06/2020
Application of High Pressure Soft Start on Compressor Load
Abstract: The high-voltage and high-power motor has a relatively large impact on the load and the power grid when starting. Thyristor series high-voltage soft starters are widely used for their superior starting performance and other advantages.
-
08/20/2020
Share How to judge common failures of air conditioners
It’s normal for the air conditioner to have problems after using it for a long time. So, how do you judge where the problem is? How to prevent and avoid these problems?
-
08/21/2020
Useless for a lifetime. Dehumidification and refrigeration of air conditioners are completely different!
This summer, the heavy rain that has come in New York caught many friends off guard, and the humid and sultry weather made the big guys complain. A small partner told the author that at this time, dehumidification is enough. The air conditioner does not need to be cooled. principle of refrigeration of central air-conditioning chillers
-
08/05/2020
How does the air conditioner collect fluoride
1. Method: The method of collecting fluorine should be correct. Under the state of turning on and cooling, open the covers of the two connecting pipe valves of the outdoor unit with a wrench, use 5 hexagonal wrenches,
-
08/13/2021
How to Find Low Side of Your Refrigerator Compressor
The compressor of a refrigerator plays a key role in the cooling effect of the refrigerator, as well as the refrigeration cycle.
-
06/21/2020
The basic structure of piston compressor_Composition system of piston compressor
The basic structure of piston compressor_Composition system of piston compressor Basic structure of piston compressor <img src="{{media url="The_basic_structure_of_piston_compressor.jpg"}}" alt="" /> Piston refrigeration compressor is mainly composed of body, crankshaft, connecting rod, piston group, valve, shaft seal, oil pump, energy adjustment device, oil circulation system and other components.
-
09/10/2020
Application of pressure sensor in air compressor control system
Take a single screw air compressor as an example to illustrate the working principle of an air compressor. The working process of a screw air compressor is divided into four processes: suction, sealing and conveying, compression and exhaust.
-
07/31/2020
Fresh air treatment and energy-saving methods of multi-line system
In the process of using air conditioners, we must consider the related functions of air conditioners on the one hand, and on the other hand, consider its energy-saving effects and reduce power consumption. The multi-line system can meet people’s needs in life while reducing input costs. Reduce energy consumption.
-
03/07/2021
AC servo driver wiring precautions
For signal line and encoder input line, please use shielded wire. Wiring length: the length of signal line from NC to AC servo driver is less than 3m, and the length of input line from AC driver to encoder is less than 20m. The ground wire should be thick wire as far as possible. According to the third grounding standard (grounding resistance < 100 Ω), one point grounding method should be adopted to connect the ground wire. If the motor and the machine tool are insulated, the motor should be grounded.
-
06/14/2020
The omni-directional strategy-fault and maintenance of piston refrigeration compressor
The omni-directional strategy-fault and maintenance of piston refrigeration compressor 1. The refrigeration compressor cannot start normally Maintenance ideas