There is no price at present, you can Request a Quote
Series | H83C Series |
Refrigeration Application | High Temperature |
Type of Refrigerant | R410A |
Generation | Fourth Generation – Basic Standard Model |
Family | Scroll (<42k) |
Nominal Capacity (BTU/Hr) | 32,000 BTU/Hr |
Motor Type | AL 3 Phase-Across the Line |
Motor Protector | Internal Line Break |
Electrical Characteristics | 460-3-60 (380/415-3-50) |
Mounting Feet Dimension (Inches) | 10.5 x 10.5 |
Shipping cost is not included
The Bristol Compressor is high quality!
Bristol Compressor H83C323DBEF
There is no price at present, you can Request a Quote
People who bought this item also viewed
Tecumseh Compressor TRK5480Y
Hitachi Compressor ASH264SN-C8LU
Daikin Compressor JT100GCVDKW@SB
Bristol Compressor H22J333DBV
Bristol Compressor H23A383DBEA
Bristol Compressor H79B30UABHA
Bristol Compressor H23A503DBEA
Bristol Compressor H2EB243ABKA
Tecumseh Compressor CAJ2464Z
GMCC Compressor YH460X3CS-4MUC1
Danfoss Compressor CH290A4BBA
TRIAD Transformer FD8-10
Schneider Contactor LC1-D62000M7C
Ebmpapst Fan A2D200-AI18-01
GTR Electric Motor FGN-15M-360-T40W
VICKERS Filter V0411B5V05
EMERSON Sight Glass AMI-2S11
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Sonnenschein Battery A602/415
Panasonic Servo Motor MSM082A1E
SOG Oil Seal TC33*50*6
Senex Transmitter DG1300-GW-1-2-15
Danfoss Solenoid Coil AC024C
LS Mecapion Encoder H40-8-3000ZV
AirTAC Air Cylinder TACQ12X5S
Recent related posts
-
08/16/2020
Can the chiller use a descaling agent for descaling
In fact, the use of a descaling agent for descaling is a common practice for the descaling work of the chiller. Therefore, the chiller can completely use the descaling agent for descaling. This is not a problem.
-
06/23/2020
What is the solution of air conditioning not cooling
There are many reasons why the air conditioner is not cooling. For example, if the air conditioner refrigerant is insufficient, you can find a professional to add snow; secondly, it may be caused by the error of the air conditioner installation, such as the ventilation pipe is too long. It is recommended to shorten the length of the ventilation pipe; A lot of dust stains accumulate on the radiator and cause no cooling. It is recommended to clean the air conditioner.
-
06/14/2020
How about ultra-small refrigeration compressors Features introduction of ultra-small refrigeration compressors
Among the components of our refrigeration compressor, the compressor is very important, and an ultra-small refrigeration compressor is widely used in our equipment with a refrigeration capacity of less than 1KW, so today I will introduce you to us Some of 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜
-
11/23/2023
How to Keep Your Computer Cool (Desktop, Laptop, or Computer CPU Temperature is too High)
The main sources of heat in a computer are the processor (CPU) and graphics processing unit (GPU). When these components work, they generate a lot of heat.
-
08/28/2020
Analysis of working principle of screw air compressor oil system
The oil circuit system of screw air compressor includes oil tank, oil cooler, oil filter, oil cut valve, temperature control valve, etc.
-
06/21/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
-
06/30/2020
Common faults and causes of compressors
Common faults and causes of compressors Common compressor failures are as follows: L. The compressor cannot start normally The power supply voltage is too low, the motor circuit is poorly connected, or the exhaust valve is leaking, resulting in too high pressure in the crankcase. The energy regulation mechanism has failed.
-
08/14/2020
How to flush reciprocating compressor with refrigerant oil
After the refrigeration equipment and its compressor are used for a period of time, the added refrigerating oil will be naturally lost during the operation of the equipment.
-
08/17/2020
The function and selection method of throttling capillary in industrial chiller
The capillary tube in the industrial chiller is a pure copper tube with a specified length and a very thin diameter. Its inner diameter is generally between 0.5-2mm. Choose the appropriate length according to the size of the chiller, and then process it i碌7館2 䀀 締眪
-
08/15/2023
What are the Pros and Cons of Heat Pumps
Heat pumps are a popular alternative to traditional heating and cooling systems. They work by transferring heat from one location to another, providing both warmth in the winter and coolness in the summer.