Power source (not supplied) Limited power source according to UL/EN 60950‑1 standards or limited energy circuit
according to UL/EN 61010‑1 §9.4
Output signal 4…20 mA/HART
Signal resolution 1.6 µA
Load resistor (Un
- Umin.)/0.022 A
Fault signal Current output: mA value unchanged, 20.5 mA, 22 mA or <3.6 mA (adjustable)
Max. output current 22 mA
Measuring range resolution Max. 1 mm
Measuring frequency 55 kHz
Measuring cycle time >2 s (dependent on the parameter adjustment)
Temperature coefficient 0.06%/10K (average temperature coefficient of the zero signal - temperature error)
Vibration resistance Mechanical vibrations with 4 g and 5…100 Hz (tested according to the guidelines of German Lloyd, GL directive 2)
BURKERT Level Meter 8177
People who bought this item also viewed
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
YUKEN Vane Pump PV2R34-52-153-F-LEAA-31
TEZUO Switch AZX-1000
Bosch Filter 0986AF0294
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KROM Switch DG17VC1-6W/B
CHINT Transformer JBK1-160
Chigo Air Conditioner NEW-GD12QJ66H3
Recent related posts
-
07/22/2020
The refrigerator is not cooling, and the compressor ‘buzzes’ after turning on the battery for a few seconds. What's the matter?
A few days ago, I received a call from a customer asking for repairs, saying that her refrigerator had suddenly stopped cooling in the past two days. The light bulb in the plug-in fresh-keeping room was on, and no movement was heard.
-
08/11/2020
Technology Refrigeration equipment system operation analysis and energy saving measures introduction
1.Economic analysis of refrigeration equipment system operation<br></br> The amount of cold produced by refrigeration equipment is directly related to the operating conditions of the system.
-
07/26/2020
Common faults and troubleshooting methods of refrigeration compressors
The compressor is the "heart" of the refrigeration system. The compressor sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and then discharges the high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle to realize the refrigeration cycle. The editor summarizes the common faults and troubleshooting methods of the compressor to help you better maintain the compressor.
-
09/01/2022
Advantages of a Permanent Magnet Contactor
The permanent magnet contactor is a new type of low-voltage switchgear. Using the working principle of electromagnetic operation and permanent magnet holding
-
06/14/2020
In doing so, there is no need to worry about reversing the refrigeration compressor! (technology sharing)
In doing so, there is no need to worry about reversing the refrigeration compressor! (technology sharing) When the refrigeration compressor unit is in normal operation, it should also be checked accordingly to prevent the refrigeration compressor from re 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/14/2020
Solar driven adsorption refrigeration
Solar driven adsorption refrigeration Shanghai Jiaotong University Wang Ruzhu and other nearly 20 years of painstaking research "adsorption refrigeration adsorption mechanism, cycle construction and thermal design theory" won the second prize of the 2014 ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ
-
04/23/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV430~SV449)
FANUC Servo Amplifier Alarm Codes and Troubleshooting Methods
-
08/11/2020
Selection of cold storage electrical control system and other design considerations
Selection of cold storage electrical control system and other design considerations<br></br> The refrigeration electrical control system is a necessary condition to ensure that the cold storage always automatically works within the set range. Its main work flow includes:
-
09/07/2020
Why do air compressors need precision filters
Precision filter is one of the most common configurations in air compressor post-processing equipment, so what does it do? Why configure filters? Summarize the following points for your reference:
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser